ABAP Select data from SAP table /SCWM/S_PACKINFO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_PACKINFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_PACKINFO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_PACKINFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_PACKINFO TYPE STANDARD TABLE OF /SCWM/S_PACKINFO, WA_/SCWM/S_PACKINFO TYPE /SCWM/S_PACKINFO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_PACKINFO> TYPE /SCWM/S_PACKINFO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_PACKINFO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_PACKINFO INTO TABLE IT_/SCWM/S_PACKINFO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_PACKINFO * INTO TABLE @DATA(IT_/SCWM/S_PACKINFO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_PACKINFO INDEX 1 INTO DATA(WA_/SCWM/S_PACKINFO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_PACKINFO ASSIGNING </SCWM/S_PACKINFO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_PACKINFO>-MATID = 1.
</SCWM/S_PACKINFO>-LGNUM = 1.
</SCWM/S_PACKINFO>-QUANCLA = 1.
</SCWM/S_PACKINFO>-PMATNR = 1.
</SCWM/S_PACKINFO>-HUTYP = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_PACKINFO INTO WA_/SCWM/S_PACKINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_PACKINFO-UOM, sy-vline,
WA_/SCWM/S_PACKINFO-QUANTITY, sy-vline,
WA_/SCWM/S_PACKINFO-WEIGHT, sy-vline,
WA_/SCWM/S_PACKINFO-WEIGHT_UOM, sy-vline,
WA_/SCWM/S_PACKINFO-VOLUM, sy-vline,
WA_/SCWM/S_PACKINFO-VOLUM_UOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_PACKINFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_PACKINFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_PACKINFO INTO WA_/SCWM/S_PACKINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_PACKINFO-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACKINFO-MATID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MDLPD, internal->external for field PMATNR CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_PACKINFO-PMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACKINFO-PMATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACKINFO-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACKINFO-UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACKINFO-WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACKINFO-WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOLUM_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACKINFO-VOLUM_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACKINFO-VOLUM_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PACKINFO-UNIT_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PACKINFO-UNIT_LWH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_PACKINFO_STR,
MATID TYPE STRING,
LGNUM TYPE STRING,
QUANCLA TYPE STRING,
PMATNR TYPE STRING,
HUTYP TYPE STRING,
UOM TYPE STRING,
QUANTITY TYPE STRING,
WEIGHT TYPE STRING,
WEIGHT_UOM TYPE STRING,
VOLUM TYPE STRING,
VOLUM_UOM TYPE STRING,
CAPA TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
UNIT_LWH TYPE STRING,
NEST_FTR TYPE STRING,
USE_FOR_SLOT TYPE STRING,
FLG_MINIMUM_PS TYPE STRING,
LEVEL_TYPE TYPE STRING,
LEVEL_DESC TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_PACKINFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_PACKINFO_STR-MATID sy-vline
WA_/SCWM/S_PACKINFO_STR-LGNUM sy-vline
WA_/SCWM/S_PACKINFO_STR-QUANCLA sy-vline
WA_/SCWM/S_PACKINFO_STR-PMATNR sy-vline
WA_/SCWM/S_PACKINFO_STR-HUTYP sy-vline
WA_/SCWM/S_PACKINFO_STR-UOM sy-vline
WA_/SCWM/S_PACKINFO_STR-QUANTITY sy-vline
WA_/SCWM/S_PACKINFO_STR-WEIGHT sy-vline
WA_/SCWM/S_PACKINFO_STR-WEIGHT_UOM sy-vline
WA_/SCWM/S_PACKINFO_STR-VOLUM sy-vline
WA_/SCWM/S_PACKINFO_STR-VOLUM_UOM sy-vline
WA_/SCWM/S_PACKINFO_STR-CAPA sy-vline
WA_/SCWM/S_PACKINFO_STR-LENGTH sy-vline
WA_/SCWM/S_PACKINFO_STR-WIDTH sy-vline
WA_/SCWM/S_PACKINFO_STR-HEIGHT sy-vline
WA_/SCWM/S_PACKINFO_STR-UNIT_LWH sy-vline
WA_/SCWM/S_PACKINFO_STR-NEST_FTR sy-vline
WA_/SCWM/S_PACKINFO_STR-USE_FOR_SLOT sy-vline
WA_/SCWM/S_PACKINFO_STR-FLG_MINIMUM_PS sy-vline
WA_/SCWM/S_PACKINFO_STR-LEVEL_TYPE sy-vline
WA_/SCWM/S_PACKINFO_STR-LEVEL_DESC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.