ABAP Select data from SAP table /SCWM/S_PPR_PUTREQ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_PPR_PUTREQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_PPR_PUTREQ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_PPR_PUTREQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_PPR_PUTREQ TYPE STANDARD TABLE OF /SCWM/S_PPR_PUTREQ,
      WA_/SCWM/S_PPR_PUTREQ TYPE /SCWM/S_PPR_PUTREQ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_PPR_PUTREQ> TYPE /SCWM/S_PPR_PUTREQ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_PPR_PUTREQ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_PPR_PUTREQ
  INTO TABLE IT_/SCWM/S_PPR_PUTREQ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_PPR_PUTREQ
*  INTO TABLE @DATA(IT_/SCWM/S_PPR_PUTREQ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_PPR_PUTREQ INDEX 1 INTO DATA(WA_/SCWM/S_PPR_PUTREQ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_PPR_PUTREQ ASSIGNING </SCWM/S_PPR_PUTREQ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_PPR_PUTREQ>-SEQNO = 1.
</SCWM/S_PPR_PUTREQ>-LGNUM = 1.
</SCWM/S_PPR_PUTREQ>-NLTYPG = 1.
</SCWM/S_PPR_PUTREQ>-NLTYP = 1.
</SCWM/S_PPR_PUTREQ>-NLBER = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_PPR_PUTREQ INTO WA_/SCWM/S_PPR_PUTREQ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_PPR_PUTREQ-NPTYP, sy-vline,
WA_/SCWM/S_PPR_PUTREQ-NLPLA, sy-vline,
WA_/SCWM/S_PPR_PUTREQ-NLENR, sy-vline,
WA_/SCWM/S_PPR_PUTREQ-AAREA, sy-vline,
WA_/SCWM/S_PPR_PUTREQ-VLENR, sy-vline,
WA_/SCWM/S_PPR_PUTREQ-SGUID_HU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_PPR_PUTREQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_PPR_PUTREQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_PPR_PUTREQ INTO WA_/SCWM/S_PPR_PUTREQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit HUID, internal->external for field NLENR CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-NLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-NLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field VLENR CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-VLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-VLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DTU_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-DTU_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-DTU_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PSA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-PSA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-PSA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-MATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-OWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PPR_PUTREQ-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PPR_PUTREQ-ENTITLED.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_PPR_PUTREQ_STR,
SEQNO TYPE STRING,
LGNUM TYPE STRING,
NLTYPG TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NPTYP TYPE STRING,
NLPLA TYPE STRING,
NLENR TYPE STRING,
AAREA TYPE STRING,
VLENR TYPE STRING,
SGUID_HU TYPE STRING,
DRSRC TYPE STRING,
DTU_NUM TYPE STRING,
PROCTY TYPE STRING,
QUAN TYPE STRING,
UNIT TYPE STRING,
HOMVE TYPE STRING,
FLGHUTO TYPE STRING,
PSA TYPE STRING,
MATID TYPE STRING,
BATCHID TYPE STRING,
CAT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_ITMNO TYPE STRING,
DOCCAT TYPE STRING,
STOCK_USAGE TYPE STRING,
OWNER TYPE STRING,
OWNER_ROLE TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_ROLE TYPE STRING,
STOCK_CNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_PPR_PUTREQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-SEQNO sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-LGNUM sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-NLTYPG sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-NLTYP sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-NLBER sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-NPTYP sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-NLPLA sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-NLENR sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-AAREA sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-VLENR sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-SGUID_HU sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-DRSRC sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-DTU_NUM sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-PROCTY sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-QUAN sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-UNIT sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-HOMVE sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-FLGHUTO sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-PSA sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-MATID sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-BATCHID sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-CAT sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-STOCK_DOCNO sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-STOCK_ITMNO sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-DOCCAT sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-STOCK_USAGE sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-OWNER sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-OWNER_ROLE sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-ENTITLED sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-ENTITLED_ROLE sy-vline
WA_/SCWM/S_PPR_PUTREQ_STR-STOCK_CNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.