ABAP Select data from SAP table /SCWM/S_QIOT3_PRP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_QIOT3_PRP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_QIOT3_PRP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_QIOT3_PRP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_QIOT3_PRP TYPE STANDARD TABLE OF /SCWM/S_QIOT3_PRP,
      WA_/SCWM/S_QIOT3_PRP TYPE /SCWM/S_QIOT3_PRP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_QIOT3_PRP> TYPE /SCWM/S_QIOT3_PRP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_QIOT3_PRP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_QIOT3_PRP
  INTO TABLE IT_/SCWM/S_QIOT3_PRP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_QIOT3_PRP
*  INTO TABLE @DATA(IT_/SCWM/S_QIOT3_PRP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_QIOT3_PRP INDEX 1 INTO DATA(WA_/SCWM/S_QIOT3_PRP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_QIOT3_PRP ASSIGNING </SCWM/S_QIOT3_PRP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_QIOT3_PRP>-VERSION = 1.
</SCWM/S_QIOT3_PRP>-LGNUM = 1.
</SCWM/S_QIOT3_PRP>-INB_PROC = 1.
</SCWM/S_QIOT3_PRP>-DOCTYPE = 1.
</SCWM/S_QIOT3_PRP>-ITEMTYPE = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_QIOT3_PRP INTO WA_/SCWM/S_QIOT3_PRP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_QIOT3_PRP-PARTYNO, sy-vline,
WA_/SCWM/S_QIOT3_PRP-PRODUCTID, sy-vline,
WA_/SCWM/S_QIOT3_PRP-ENTITLED, sy-vline,
WA_/SCWM/S_QIOT3_PRP-QGRP, sy-vline,
WA_/SCWM/S_QIOT3_PRP-COO, sy-vline,
WA_/SCWM/S_QIOT3_PRP-ICATLOCN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_QIOT3_PRP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_QIOT3_PRP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_QIOT3_PRP INTO WA_/SCWM/S_QIOT3_PRP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field PARTYNO CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-PARTYNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-PARTYNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field PRODUCTID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-PRODUCTID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-PRODUCTID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DLVUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-DLVUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-DLVUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFITEMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-REFITEMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-REFITEMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_ADD_QTY CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-UNIT_ADD_QTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-UNIT_ADD_QTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SALES_ORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-SALES_ORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-SALES_ORD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field WBS_ELEM_INT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-WBS_ELEM_INT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-WBS_ELEM_INT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VENDOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-VENDOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-VENDOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SCDL1, internal->external for field MATNRNEU CALL FUNCTION 'CONVERSION_EXIT_SCDL1_OUTPUT' EXPORTING input = WA_/SCWM/S_QIOT3_PRP-MATNRNEU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_QIOT3_PRP-MATNRNEU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_QIOT3_PRP_STR,
VERSION TYPE STRING,
LGNUM TYPE STRING,
INB_PROC TYPE STRING,
DOCTYPE TYPE STRING,
ITEMTYPE TYPE STRING,
PARTYNO TYPE STRING,
PRODUCTID TYPE STRING,
ENTITLED TYPE STRING,
QGRP TYPE STRING,
COO TYPE STRING,
ICATLOCN TYPE STRING,
DOCCAT TYPE STRING,
DOCID TYPE STRING,
HUIDENT TYPE STRING,
CHARG TYPE STRING,
DLVUOM TYPE STRING,
REFDOCCAT TYPE STRING,
REFDOCNO TYPE STRING,
REFITEMNO TYPE STRING,
QTY_Q_2_X TYPE STRING,
UNIT_ADD_QTY TYPE STRING,
CATLOCN TYPE STRING,
LMENGEZUB TYPE STRING,
LMENGE01 TYPE STRING,
LMENGE02 TYPE STRING,
LMENGE04 TYPE STRING,
LMENGE06 TYPE STRING,
WITHDRAWN_SAMPLE_QTY TYPE STRING,
SPEC_STOCK TYPE STRING,
SALES_ORD TYPE STRING,
S_ORD_ITEM TYPE STRING,
WBS_ELEM_INT TYPE STRING,
VENDOR TYPE STRING,
LICHN TYPE STRING,
VFDAT TYPE STRING,
MATNRNEU TYPE STRING,
CHARGNEU TYPE STRING,
PASTRTERM TYPE STRING,
PASTRZEIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_QIOT3_PRP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-VERSION sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LGNUM sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-INB_PROC sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-DOCTYPE sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-ITEMTYPE sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-PARTYNO sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-PRODUCTID sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-ENTITLED sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-QGRP sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-COO sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-ICATLOCN sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-DOCCAT sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-DOCID sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-HUIDENT sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-CHARG sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-DLVUOM sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-REFDOCCAT sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-REFDOCNO sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-REFITEMNO sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-QTY_Q_2_X sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-UNIT_ADD_QTY sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-CATLOCN sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LMENGEZUB sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LMENGE01 sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LMENGE02 sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LMENGE04 sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LMENGE06 sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-WITHDRAWN_SAMPLE_QTY sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-SPEC_STOCK sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-SALES_ORD sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-S_ORD_ITEM sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-WBS_ELEM_INT sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-VENDOR sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-LICHN sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-VFDAT sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-MATNRNEU sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-CHARGNEU sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-PASTRTERM sy-vline
WA_/SCWM/S_QIOT3_PRP_STR-PASTRZEIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.