ABAP Select data from SAP table /SCWM/S_RF_PACK_TO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_RF_PACK_TO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_RF_PACK_TO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_RF_PACK_TO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_RF_PACK_TO TYPE STANDARD TABLE OF /SCWM/S_RF_PACK_TO,
      WA_/SCWM/S_RF_PACK_TO TYPE /SCWM/S_RF_PACK_TO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_RF_PACK_TO> TYPE /SCWM/S_RF_PACK_TO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_RF_PACK_TO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_RF_PACK_TO
  INTO TABLE IT_/SCWM/S_RF_PACK_TO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_RF_PACK_TO
*  INTO TABLE @DATA(IT_/SCWM/S_RF_PACK_TO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_RF_PACK_TO INDEX 1 INTO DATA(WA_/SCWM/S_RF_PACK_TO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_RF_PACK_TO ASSIGNING </SCWM/S_RF_PACK_TO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_RF_PACK_TO>-PROSTHU = 1.
</SCWM/S_RF_PACK_TO>-PROSTHU_TYPE = 1.
</SCWM/S_RF_PACK_TO>-IDPLATE = 1.
</SCWM/S_RF_PACK_TO>-MATNR = 1.
</SCWM/S_RF_PACK_TO>-HUIDENT = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_RF_PACK_TO INTO WA_/SCWM/S_RF_PACK_TO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_RF_PACK_TO-MAKTX, sy-vline,
WA_/SCWM/S_RF_PACK_TO-VSOLA, sy-vline,
WA_/SCWM/S_RF_PACK_TO-ALTME, sy-vline,
WA_/SCWM/S_RF_PACK_TO-VLENR, sy-vline,
WA_/SCWM/S_RF_PACK_TO-SUMLP_U, sy-vline,
WA_/SCWM/S_RF_PACK_TO-SUMDG_U, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_RF_PACK_TO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_RF_PACK_TO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_RF_PACK_TO INTO WA_/SCWM/S_RF_PACK_TO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MDLP1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MDLP1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_PACK_TO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_PACK_TO-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_PACK_TO-HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_PACK_TO-HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QNTY1, internal->external for field VSOLA CALL FUNCTION 'CONVERSION_EXIT_QNTY1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_PACK_TO-VSOLA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_PACK_TO-VSOLA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_PACK_TO-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_PACK_TO-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field VLENR CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_PACK_TO-VLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_PACK_TO-VLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_PACK_TO-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_PACK_TO-MATID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_RF_PACK_TO_STR,
PROSTHU TYPE STRING,
PROSTHU_TYPE TYPE STRING,
IDPLATE TYPE STRING,
MATNR TYPE STRING,
HUIDENT TYPE STRING,
MAKTX TYPE STRING,
VSOLA TYPE STRING,
ALTME TYPE STRING,
VLENR TYPE STRING,
SUMLP_U TYPE STRING,
SUMDG_U TYPE STRING,
SEQNO TYPE STRING,
DSTGRP TYPE STRING,
SUMITM TYPE STRING,
SUMSHU TYPE STRING,
MATID TYPE STRING,
GUID_PARENT TYPE STRING,
GUID_STOCK TYPE STRING,
GUID_STOCK0 TYPE STRING,
VSI TYPE STRING,
GUID_VLENR TYPE STRING,
BATCHID TYPE STRING,
CHARG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_RF_PACK_TO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-PROSTHU sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-PROSTHU_TYPE sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-IDPLATE sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-MATNR sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-HUIDENT sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-MAKTX sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-VSOLA sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-ALTME sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-VLENR sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-SUMLP_U sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-SUMDG_U sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-SEQNO sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-DSTGRP sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-SUMITM sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-SUMSHU sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-MATID sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-GUID_PARENT sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-GUID_STOCK sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-GUID_STOCK0 sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-VSI sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-GUID_VLENR sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-BATCHID sy-vline
WA_/SCWM/S_RF_PACK_TO_STR-CHARG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.