ABAP Select data from SAP table /SCWM/S_RF_REHU_DLV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_RF_REHU_DLV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_RF_REHU_DLV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_RF_REHU_DLV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_RF_REHU_DLV TYPE STANDARD TABLE OF /SCWM/S_RF_REHU_DLV,
      WA_/SCWM/S_RF_REHU_DLV TYPE /SCWM/S_RF_REHU_DLV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_RF_REHU_DLV> TYPE /SCWM/S_RF_REHU_DLV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_RF_REHU_DLV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_RF_REHU_DLV
  INTO TABLE IT_/SCWM/S_RF_REHU_DLV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_RF_REHU_DLV
*  INTO TABLE @DATA(IT_/SCWM/S_RF_REHU_DLV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_RF_REHU_DLV INDEX 1 INTO DATA(WA_/SCWM/S_RF_REHU_DLV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_RF_REHU_DLV ASSIGNING </SCWM/S_RF_REHU_DLV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_RF_REHU_DLV>-LGNUM = 1.
</SCWM/S_RF_REHU_DLV>-DLVNO = 1.
</SCWM/S_RF_REHU_DLV>-SUMHU = 1.
</SCWM/S_RF_REHU_DLV>-SUMHU_PROC = 1.
</SCWM/S_RF_REHU_DLV>-HAZMAT = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_RF_REHU_DLV INTO WA_/SCWM/S_RF_REHU_DLV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_RF_REHU_DLV-HAZMAT_IND, sy-vline,
WA_/SCWM/S_RF_REHU_DLV-PROCESSED, sy-vline,
WA_/SCWM/S_RF_REHU_DLV-EXCCODE, sy-vline,
WA_/SCWM/S_RF_REHU_DLV-PMATID, sy-vline,
WA_/SCWM/S_RF_REHU_DLV-SHPMT, sy-vline,
WA_/SCWM/S_RF_REHU_DLV-TU_NUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_RF_REHU_DLV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_RF_REHU_DLV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_RF_REHU_DLV INTO WA_/SCWM/S_RF_REHU_DLV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DLVNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_REHU_DLV-DLVNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_REHU_DLV-DLVNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field PMATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_REHU_DLV-PMATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_REHU_DLV-PMATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field PARTYNO CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_REHU_DLV-PARTYNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_REHU_DLV-PARTYNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_REHU_DLV-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_REHU_DLV-UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_RF_REHU_DLV_STR,
LGNUM TYPE STRING,
DLVNO TYPE STRING,
SUMHU TYPE STRING,
SUMHU_PROC TYPE STRING,
HAZMAT TYPE STRING,
HAZMAT_IND TYPE STRING,
PROCESSED TYPE STRING,
EXCCODE TYPE STRING,
PMATID TYPE STRING,
SHPMT TYPE STRING,
TU_NUM TYPE STRING,
SCAC TYPE STRING,
TSP_SCAC TYPE STRING,
DOOR TYPE STRING,
DOOR_DLV_DATE TYPE STRING,
DOOR_DD_PAST TYPE STRING,
DOOR_DD_FUT TYPE STRING,
ASN TYPE STRING,
RDOCCAT TYPE STRING,
RDOCID TYPE STRING,
RITMID TYPE STRING,
TEXT_IND TYPE STRING,
ACT_TYPE TYPE STRING,
PARTYID TYPE STRING,
PARTYTEXT TYPE STRING,
DOCCAT TYPE STRING,
J_VORGANG TYPE STRING,
DOCID TYPE STRING,
PARTYNO TYPE STRING,
PROCTY TYPE STRING,
EXC_TAB TYPE STRING,
VHI TYPE STRING,
ITEM_ID TYPE STRING,
UOM TYPE STRING,
MARK_SEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_RF_REHU_DLV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-LGNUM sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DLVNO sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-SUMHU sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-SUMHU_PROC sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-HAZMAT sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-HAZMAT_IND sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-PROCESSED sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-EXCCODE sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-PMATID sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-SHPMT sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-TU_NUM sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-SCAC sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-TSP_SCAC sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DOOR sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DOOR_DLV_DATE sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DOOR_DD_PAST sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DOOR_DD_FUT sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-ASN sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-RDOCCAT sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-RDOCID sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-RITMID sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-TEXT_IND sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-ACT_TYPE sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-PARTYID sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-PARTYTEXT sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DOCCAT sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-J_VORGANG sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-DOCID sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-PARTYNO sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-PROCTY sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-EXC_TAB sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-VHI sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-ITEM_ID sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-UOM sy-vline
WA_/SCWM/S_RF_REHU_DLV_STR-MARK_SEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.