ABAP Select data from SAP table /SCWM/S_RF_TW_FLOORCHECK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_RF_TW_FLOORCHECK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_RF_TW_FLOORCHECK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_RF_TW_FLOORCHECK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_RF_TW_FLOORCHECK TYPE STANDARD TABLE OF /SCWM/S_RF_TW_FLOORCHECK,
      WA_/SCWM/S_RF_TW_FLOORCHECK TYPE /SCWM/S_RF_TW_FLOORCHECK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_RF_TW_FLOORCHECK> TYPE /SCWM/S_RF_TW_FLOORCHECK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_RF_TW_FLOORCHECK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_RF_TW_FLOORCHECK
  INTO TABLE IT_/SCWM/S_RF_TW_FLOORCHECK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_RF_TW_FLOORCHECK
*  INTO TABLE @DATA(IT_/SCWM/S_RF_TW_FLOORCHECK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_RF_TW_FLOORCHECK INDEX 1 INTO DATA(WA_/SCWM/S_RF_TW_FLOORCHECK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_RF_TW_FLOORCHECK ASSIGNING </SCWM/S_RF_TW_FLOORCHECK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_RF_TW_FLOORCHECK>-LGNUM = 1.
</SCWM/S_RF_TW_FLOORCHECK>-SCAN_HUIDENT = 1.
</SCWM/S_RF_TW_FLOORCHECK>-SEL_HUIDENT = 1.
</SCWM/S_RF_TW_FLOORCHECK>-DOCCAT = 1.
</SCWM/S_RF_TW_FLOORCHECK>-HAZMAT = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_RF_TW_FLOORCHECK INTO WA_/SCWM/S_RF_TW_FLOORCHECK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_RF_TW_FLOORCHECK-SHIPPER, sy-vline,
WA_/SCWM/S_RF_TW_FLOORCHECK-SHIPPER_TEXT, sy-vline,
WA_/SCWM/S_RF_TW_FLOORCHECK-CONSIGNEE, sy-vline,
WA_/SCWM/S_RF_TW_FLOORCHECK-CONSIGNEE_TEXT, sy-vline,
WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WEIGHT, sy-vline,
WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WEIGHT_UOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_RF_TW_FLOORCHECK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_RF_TW_FLOORCHECK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_RF_TW_FLOORCHECK INTO WA_/SCWM/S_RF_TW_FLOORCHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit RFHUL, internal->external for field SCAN_HUIDENT CALL FUNCTION 'CONVERSION_EXIT_RFHUL_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-SCAN_HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-SCAN_HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field SEL_HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-SEL_HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-SEL_HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field SHIPPER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-SHIPPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-SHIPPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field CONSIGNEE CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-CONSIGNEE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-CONSIGNEE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QNTY1, internal->external for field HU_WEIGHT CALL FUNCTION 'CONVERSION_EXIT_QNTY1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WEIGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WEIGHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HU_WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QNTY1, internal->external for field HU_VOLUME CALL FUNCTION 'CONVERSION_EXIT_QNTY1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_VOLUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_VOLUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HU_VOLUME_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_VOLUME_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_VOLUME_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QNTY1, internal->external for field HU_LENGTH CALL FUNCTION 'CONVERSION_EXIT_QNTY1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_LENGTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_LENGTH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QNTY1, internal->external for field HU_WIDTH CALL FUNCTION 'CONVERSION_EXIT_QNTY1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WIDTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WIDTH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QNTY1, internal->external for field HU_HEIGHT CALL FUNCTION 'CONVERSION_EXIT_QNTY1_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_HEIGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_HEIGHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HU_LENGTH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_LENGTH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_LENGTH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HU_WIDTH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WIDTH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_WIDTH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HU_HEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HU_HEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HU_HEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LWH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-LWH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-LWH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field ULDIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-ULDIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-ULDIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field HIGHER_HU CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-HIGHER_HU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-HIGHER_HU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_RF_TW_FLOORCHECK-TSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_RF_TW_FLOORCHECK-TSP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_RF_TW_FLOORCHECK_STR,
LGNUM TYPE STRING,
SCAN_HUIDENT TYPE STRING,
SEL_HUIDENT TYPE STRING,
DOCCAT TYPE STRING,
HAZMAT TYPE STRING,
SHIPPER TYPE STRING,
SHIPPER_TEXT TYPE STRING,
CONSIGNEE TYPE STRING,
CONSIGNEE_TEXT TYPE STRING,
HU_WEIGHT TYPE STRING,
HU_WEIGHT_UOM TYPE STRING,
HU_VOLUME TYPE STRING,
HU_VOLUME_UOM TYPE STRING,
HU_LENGTH TYPE STRING,
HU_WIDTH TYPE STRING,
HU_HEIGHT TYPE STRING,
HU_LENGTH_UOM TYPE STRING,
HU_WIDTH_UOM TYPE STRING,
HU_HEIGHT_UOM TYPE STRING,
LWH_UOM TYPE STRING,
ULDIDENT TYPE STRING,
GUID_HU TYPE STRING,
LGPLA TYPE STRING,
VLPLA TYPE STRING,
NLPLA TYPE STRING,
STATUS TYPE STRING,
STATUS_TEXT TYPE STRING,
TWHUTYPE TYPE STRING,
HIGHER_HU TYPE STRING,
DATE_OUT_YARD TYPE STRING,
DGIND TYPE STRING,
ORIGINAL_DOCCAT TYPE STRING,
ORIGINAL_DOCID TYPE STRING,
ORIGINAL_ITMID TYPE STRING,
DISCR_IND TYPE STRING,
CLF_IND TYPE STRING,
HIGH_VALUE TYPE STRING,
BONDED_CARGO TYPE STRING,
OVERSIZED TYPE STRING,
NOT_STACKABLE TYPE STRING,
DAMAGED TYPE STRING,
CONT_INF_IND TYPE STRING,
HU_LOADED TYPE STRING,
TU_NUM_EXT TYPE STRING,
TSP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_RF_TW_FLOORCHECK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-LGNUM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-SCAN_HUIDENT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-SEL_HUIDENT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-DOCCAT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HAZMAT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-SHIPPER sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-SHIPPER_TEXT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-CONSIGNEE sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-CONSIGNEE_TEXT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_WEIGHT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_WEIGHT_UOM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_VOLUME sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_VOLUME_UOM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_LENGTH sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_WIDTH sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_HEIGHT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_LENGTH_UOM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_WIDTH_UOM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_HEIGHT_UOM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-LWH_UOM sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-ULDIDENT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-GUID_HU sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-LGPLA sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-VLPLA sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-NLPLA sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-STATUS sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-STATUS_TEXT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-TWHUTYPE sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HIGHER_HU sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-DATE_OUT_YARD sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-DGIND sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-ORIGINAL_DOCCAT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-ORIGINAL_DOCID sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-ORIGINAL_ITMID sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-DISCR_IND sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-CLF_IND sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HIGH_VALUE sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-BONDED_CARGO sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-OVERSIZED sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-NOT_STACKABLE sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-DAMAGED sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-CONT_INF_IND sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-HU_LOADED sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-TU_NUM_EXT sy-vline
WA_/SCWM/S_RF_TW_FLOORCHECK_STR-TSP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.