ABAP Select data from SAP table /SCWM/S_SCON_TASKS_LIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_SCON_TASKS_LIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_SCON_TASKS_LIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_SCON_TASKS_LIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_SCON_TASKS_LIST TYPE STANDARD TABLE OF /SCWM/S_SCON_TASKS_LIST,
      WA_/SCWM/S_SCON_TASKS_LIST TYPE /SCWM/S_SCON_TASKS_LIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_SCON_TASKS_LIST> TYPE /SCWM/S_SCON_TASKS_LIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_SCON_TASKS_LIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_SCON_TASKS_LIST
  INTO TABLE IT_/SCWM/S_SCON_TASKS_LIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_SCON_TASKS_LIST
*  INTO TABLE @DATA(IT_/SCWM/S_SCON_TASKS_LIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_SCON_TASKS_LIST INDEX 1 INTO DATA(WA_/SCWM/S_SCON_TASKS_LIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_SCON_TASKS_LIST ASSIGNING </SCWM/S_SCON_TASKS_LIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_SCON_TASKS_LIST>-CONS_GRP = 1.
</SCWM/S_SCON_TASKS_LIST>-VLTYP = 1.
</SCWM/S_SCON_TASKS_LIST>-VLBER = 1.
</SCWM/S_SCON_TASKS_LIST>-VLPLA = 1.
</SCWM/S_SCON_TASKS_LIST>-LPTYP = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_SCON_TASKS_LIST INTO WA_/SCWM/S_SCON_TASKS_LIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_SCON_TASKS_LIST-AISLE, sy-vline,
WA_/SCWM/S_SCON_TASKS_LIST-REM_WEIGHT, sy-vline,
WA_/SCWM/S_SCON_TASKS_LIST-UNIT_W, sy-vline,
WA_/SCWM/S_SCON_TASKS_LIST-REM_VOLUM, sy-vline,
WA_/SCWM/S_SCON_TASKS_LIST-UNIT_V, sy-vline,
WA_/SCWM/S_SCON_TASKS_LIST-FCAPA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_SCON_TASKS_LIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_SCON_TASKS_LIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_SCON_TASKS_LIST INTO WA_/SCWM/S_SCON_TASKS_LIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_SCON_TASKS_LIST-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCON_TASKS_LIST-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_SCON_TASKS_LIST-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCON_TASKS_LIST-UNIT_V.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_SCON_TASKS_LIST-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCON_TASKS_LIST-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_SCON_TASKS_LIST-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCON_TASKS_LIST-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_SCON_TASKS_LIST-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCON_TASKS_LIST-MEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_SCON_TASKS_LIST_STR,
CONS_GRP TYPE STRING,
VLTYP TYPE STRING,
VLBER TYPE STRING,
VLPLA TYPE STRING,
LPTYP TYPE STRING,
AISLE TYPE STRING,
REM_WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
REM_VOLUM TYPE STRING,
UNIT_V TYPE STRING,
FCAPA TYPE STRING,
REM_ANZLE TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
MOVES TYPE STRING,
SPLIT TYPE STRING,
PI_ACTIVE TYPE STRING,
QUAN TYPE STRING,
MEINS TYPE STRING,
PAL TYPE STRING,
MEINH TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
FBINS TYPE STRING,
BATCHID TYPE STRING,
DESCRIPTION TYPE STRING,
DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_SCON_TASKS_LIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-CONS_GRP sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-VLTYP sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-VLBER sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-VLPLA sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-LPTYP sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-AISLE sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-REM_WEIGHT sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-UNIT_W sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-REM_VOLUM sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-UNIT_V sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-FCAPA sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-REM_ANZLE sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-MATNR sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-CHARG sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-MOVES sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-SPLIT sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-PI_ACTIVE sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-QUAN sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-MEINS sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-PAL sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-MEINH sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-UMREZ sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-UMREN sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-FBINS sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-BATCHID sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-DESCRIPTION sy-vline
WA_/SCWM/S_SCON_TASKS_LIST_STR-DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.