ABAP Select data from SAP table /SCWM/S_STOCK_AUOM_NOT_PUOM into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_STOCK_AUOM_NOT_PUOM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_STOCK_AUOM_NOT_PUOM. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_STOCK_AUOM_NOT_PUOM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_STOCK_AUOM_NOT_PUOM TYPE STANDARD TABLE OF /SCWM/S_STOCK_AUOM_NOT_PUOM, WA_/SCWM/S_STOCK_AUOM_NOT_PUOM TYPE /SCWM/S_STOCK_AUOM_NOT_PUOM, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_STOCK_AUOM_NOT_PUOM> TYPE /SCWM/S_STOCK_AUOM_NOT_PUOM. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_STOCK_AUOM_NOT_PUOM. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_STOCK_AUOM_NOT_PUOM INTO TABLE IT_/SCWM/S_STOCK_AUOM_NOT_PUOM. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_STOCK_AUOM_NOT_PUOM * INTO TABLE @DATA(IT_/SCWM/S_STOCK_AUOM_NOT_PUOM2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_STOCK_AUOM_NOT_PUOM INDEX 1 INTO DATA(WA_/SCWM/S_STOCK_AUOM_NOT_PUOM2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_STOCK_AUOM_NOT_PUOM ASSIGNING </SCWM/S_STOCK_AUOM_NOT_PUOM>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_STOCK_AUOM_NOT_PUOM>-LGNUM = 1.
</SCWM/S_STOCK_AUOM_NOT_PUOM>-LGTYP = 1.
</SCWM/S_STOCK_AUOM_NOT_PUOM>-LGPLA = 1.
</SCWM/S_STOCK_AUOM_NOT_PUOM>-MATNR = 1.
</SCWM/S_STOCK_AUOM_NOT_PUOM>-PUOM = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_STOCK_AUOM_NOT_PUOM INTO WA_/SCWM/S_STOCK_AUOM_NOT_PUOM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ALTME, sy-vline,
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-GUID_STOCK, sy-vline,
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-GUID_PARENT, sy-vline,
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-SKZUA, sy-vline,
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-SKZUE, sy-vline,
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-SKZSI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_STOCK_AUOM_NOT_PUOM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_STOCK_AUOM_NOT_PUOM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_STOCK_AUOM_NOT_PUOM INTO WA_/SCWM/S_STOCK_AUOM_NOT_PUOM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field PUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-PUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-PUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ALTME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field CWUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-CWUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-CWUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-OWNER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ENTITLED.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-DOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-DOCNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ITMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ITMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-ITMNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-INSPDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-INSPDOCNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PSA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-PSA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_STOCK_AUOM_NOT_PUOM-PSA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR,
LGNUM TYPE STRING,
LGTYP TYPE STRING,
LGPLA TYPE STRING,
MATNR TYPE STRING,
PUOM TYPE STRING,
ALTME TYPE STRING,
GUID_STOCK TYPE STRING,
GUID_PARENT TYPE STRING,
SKZUA TYPE STRING,
SKZUE TYPE STRING,
SKZSI TYPE STRING,
INC_QUAN TYPE STRING,
OUT_QUAN TYPE STRING,
QUAN TYPE STRING,
ABSQUAN TYPE STRING,
UNIT TYPE STRING,
INC_QUAN_A TYPE STRING,
OUT_QUAN_A TYPE STRING,
QUAN_A TYPE STRING,
ABSQUAN_A TYPE STRING,
CWQUAN TYPE STRING,
CWUNIT TYPE STRING,
CWEXACT TYPE STRING,
MAKTX TYPE STRING,
CAT TYPE STRING,
CAT_TXT TYPE STRING,
CHARG TYPE STRING,
BRESTR TYPE STRING,
COO TYPE STRING,
OWNER TYPE STRING,
ENTITLED TYPE STRING,
STOCK_USAGE TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_ITMNO TYPE STRING,
DOCCAT TYPE STRING,
DOCNO TYPE STRING,
ITMNO TYPE STRING,
VFDAT TYPE STRING,
UI_WDATT TYPE STRING,
UI_WDATU TYPE STRING,
DUMMY_FIELD TYPE STRING,
ZEUGN TYPE STRING,
INSPTYP TYPE STRING,
INSPDOCNO TYPE STRING,
IDPLATE TYPE STRING,
QUANT_COUNT TYPE STRING,
AISLE TYPE STRING,
STACK TYPE STRING,
LVL_V TYPE STRING,
BINSC TYPE STRING,
DEPTH TYPE STRING,
PSA TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-LGNUM sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-LGTYP sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-LGPLA sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-MATNR sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-PUOM sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-ALTME sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-GUID_STOCK sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-GUID_PARENT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-SKZUA sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-SKZUE sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-SKZSI sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-INC_QUAN sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-OUT_QUAN sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-QUAN sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-ABSQUAN sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-UNIT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-INC_QUAN_A sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-OUT_QUAN_A sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-QUAN_A sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-ABSQUAN_A sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-CWQUAN sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-CWUNIT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-CWEXACT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-MAKTX sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-CAT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-CAT_TXT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-CHARG sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-BRESTR sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-COO sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-OWNER sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-ENTITLED sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-STOCK_USAGE sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-STOCK_DOCNO sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-STOCK_ITMNO sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-DOCCAT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-DOCNO sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-ITMNO sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-VFDAT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-UI_WDATT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-UI_WDATU sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-DUMMY_FIELD sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-ZEUGN sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-INSPTYP sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-INSPDOCNO sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-IDPLATE sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-QUANT_COUNT sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-AISLE sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-STACK sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-LVL_V sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-BINSC sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-DEPTH sy-vline
WA_/SCWM/S_STOCK_AUOM_NOT_PUOM_STR-PSA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.