ABAP Select data from SAP table /SCWM/S_TO_CREA_HU_INT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_TO_CREA_HU_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_TO_CREA_HU_INT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_TO_CREA_HU_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_TO_CREA_HU_INT TYPE STANDARD TABLE OF /SCWM/S_TO_CREA_HU_INT, WA_/SCWM/S_TO_CREA_HU_INT TYPE /SCWM/S_TO_CREA_HU_INT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_TO_CREA_HU_INT> TYPE /SCWM/S_TO_CREA_HU_INT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_TO_CREA_HU_INT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_TO_CREA_HU_INT INTO TABLE IT_/SCWM/S_TO_CREA_HU_INT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_TO_CREA_HU_INT * INTO TABLE @DATA(IT_/SCWM/S_TO_CREA_HU_INT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_TO_CREA_HU_INT INDEX 1 INTO DATA(WA_/SCWM/S_TO_CREA_HU_INT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_TO_CREA_HU_INT ASSIGNING </SCWM/S_TO_CREA_HU_INT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_TO_CREA_HU_INT>-HUIDENT = 1.
</SCWM/S_TO_CREA_HU_INT>-GUID_HU = 1.
</SCWM/S_TO_CREA_HU_INT>-PROCTY = 1.
</SCWM/S_TO_CREA_HU_INT>-PRSRC = 1.
</SCWM/S_TO_CREA_HU_INT>-REASON = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_TO_CREA_HU_INT INTO WA_/SCWM/S_TO_CREA_HU_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_TO_CREA_HU_INT-CRETO, sy-vline,
WA_/SCWM/S_TO_CREA_HU_INT-SQUIT, sy-vline,
WA_/SCWM/S_TO_CREA_HU_INT-NOROU, sy-vline,
WA_/SCWM/S_TO_CREA_HU_INT-NLTYP, sy-vline,
WA_/SCWM/S_TO_CREA_HU_INT-NLTYPG, sy-vline,
WA_/SCWM/S_TO_CREA_HU_INT-NLBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_TO_CREA_HU_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_TO_CREA_HU_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_TO_CREA_HU_INT INTO WA_/SCWM/S_TO_CREA_HU_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit HUID, internal->external for field HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-HUIDENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DTU_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-DTU_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-DTU_NUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSPWM, internal->external for field DTSP CALL FUNCTION 'CONVERSION_EXIT_TSPWM_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-DTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-DTSP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit HUID, internal->external for field NLENR CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-NLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-NLENR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPH0, internal->external for field WHO CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-WHO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-WHO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit SPDEV, internal->external for field LDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-LDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-LDEST.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPH0, internal->external for field WAVE CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-WAVE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-WAVE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPH0, internal->external for field WAVE_ITM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-WAVE_ITM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-WAVE_ITM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit KNBCV, internal->external for field KANBAN CALL FUNCTION 'CONVERSION_EXIT_KNBCV_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-KANBAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-KANBAN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPH0, internal->external for field REF_WT_RSRC CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-REF_WT_RSRC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-REF_WT_RSRC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PSA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_TO_CREA_HU_INT-PSA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_TO_CREA_HU_INT-PSA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_TO_CREA_HU_INT_STR,
HUIDENT TYPE STRING,
GUID_HU TYPE STRING,
PROCTY TYPE STRING,
PRSRC TYPE STRING,
REASON TYPE STRING,
CRETO TYPE STRING,
SQUIT TYPE STRING,
NOROU TYPE STRING,
NLTYP TYPE STRING,
NLTYPG TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
DRSRC TYPE STRING,
DLOGPOS TYPE STRING,
DTU_NUM TYPE STRING,
DTU_NUM_EXT TYPE STRING,
DTSP TYPE STRING,
NLENR TYPE STRING,
DGUID_HU TYPE STRING,
WHO TYPE STRING,
GUID_TO TYPE STRING,
SEQNO TYPE STRING,
LDEST TYPE STRING,
PICK_COMP_DT TYPE STRING,
RDOCRELEVANT TYPE STRING,
WHCOUNT TYPE STRING,
KIT_CREA TYPE STRING,
DSTGRP TYPE STRING,
SATIND TYPE STRING,
WHOSEQ TYPE STRING,
WAVE TYPE STRING,
WAVE_ITM TYPE STRING,
WAVECAT TYPE STRING,
INACTIV TYPE STRING,
VAS TYPE STRING,
MFS_CS TYPE STRING,
ZEILE TYPE STRING,
LINE_ID TYPE STRING,
JIT_RELEVANCE TYPE STRING,
KANBAN TYPE STRING,
REF_WT_RSRC TYPE STRING,
PSA TYPE STRING,
NOLOCK TYPE STRING,
PAS_RELEVANT TYPE STRING,
CREA_HU_DUMMY TYPE STRING,
GUID_PAS TYPE STRING,
MES_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_TO_CREA_HU_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-HUIDENT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-GUID_HU sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-PROCTY sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-PRSRC sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-REASON sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-CRETO sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-SQUIT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NOROU sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NLTYP sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NLTYPG sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NLBER sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NLPLA sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DRSRC sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DLOGPOS sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DTU_NUM sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DTU_NUM_EXT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DTSP sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NLENR sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DGUID_HU sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-WHO sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-GUID_TO sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-SEQNO sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-LDEST sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-PICK_COMP_DT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-RDOCRELEVANT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-WHCOUNT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-KIT_CREA sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-DSTGRP sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-SATIND sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-WHOSEQ sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-WAVE sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-WAVE_ITM sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-WAVECAT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-INACTIV sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-VAS sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-MFS_CS sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-ZEILE sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-LINE_ID sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-JIT_RELEVANCE sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-KANBAN sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-REF_WT_RSRC sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-PSA sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-NOLOCK sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-PAS_RELEVANT sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-CREA_HU_DUMMY sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-GUID_PAS sy-vline
WA_/SCWM/S_TO_CREA_HU_INT_STR-MES_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.