ABAP Select data from SAP table /SCWM/S_VAS_ACT_INT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_VAS_ACT_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_VAS_ACT_INT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_VAS_ACT_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_VAS_ACT_INT TYPE STANDARD TABLE OF /SCWM/S_VAS_ACT_INT, WA_/SCWM/S_VAS_ACT_INT TYPE /SCWM/S_VAS_ACT_INT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_VAS_ACT_INT> TYPE /SCWM/S_VAS_ACT_INT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_VAS_ACT_INT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_VAS_ACT_INT INTO TABLE IT_/SCWM/S_VAS_ACT_INT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_VAS_ACT_INT * INTO TABLE @DATA(IT_/SCWM/S_VAS_ACT_INT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_VAS_ACT_INT INDEX 1 INTO DATA(WA_/SCWM/S_VAS_ACT_INT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_VAS_ACT_INT ASSIGNING </SCWM/S_VAS_ACT_INT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_VAS_ACT_INT>-ACTIVITY = 1.
</SCWM/S_VAS_ACT_INT>-VAS_GUID = 1.
</SCWM/S_VAS_ACT_INT>-ACT_GUID = 1.
</SCWM/S_VAS_ACT_INT>-ACT_SEQ = 1.
</SCWM/S_VAS_ACT_INT>-PS_LEVEL = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_VAS_ACT_INT INTO WA_/SCWM/S_VAS_ACT_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_VAS_ACT_INT-COMPLQTY, sy-vline,
WA_/SCWM/S_VAS_ACT_INT-BASE_UNIT, sy-vline,
WA_/SCWM/S_VAS_ACT_INT-STATUS, sy-vline,
WA_/SCWM/S_VAS_ACT_INT-STARTED_AT, sy-vline,
WA_/SCWM/S_VAS_ACT_INT-ENDED_AT, sy-vline,
WA_/SCWM/S_VAS_ACT_INT-CHGUSR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_VAS_ACT_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_VAS_ACT_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_VAS_ACT_INT INTO WA_/SCWM/S_VAS_ACT_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field BASE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-BASE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-BASE_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field STARTED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-STARTED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-STARTED_AT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field ENDED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-ENDED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-ENDED_AT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field CHGTST CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-CHGTST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-CHGTST.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-MATID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field PL_START_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-PL_START_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-PL_START_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field PL_END_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-PL_END_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-PL_END_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_T CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-UNIT_T IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-UNIT_T.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field PLAN_QTY_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-PLAN_QTY_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-PLAN_QTY_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PLAN_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_VAS_ACT_INT-PLAN_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_VAS_ACT_INT-PLAN_MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_VAS_ACT_INT_STR,
ACTIVITY TYPE STRING,
VAS_GUID TYPE STRING,
ACT_GUID TYPE STRING,
ACT_SEQ TYPE STRING,
PS_LEVEL TYPE STRING,
COMPLQTY TYPE STRING,
BASE_UNIT TYPE STRING,
STATUS TYPE STRING,
STARTED_AT TYPE STRING,
ENDED_AT TYPE STRING,
CHGUSR TYPE STRING,
CHGTST TYPE STRING,
WORKCENTER TYPE STRING,
PROCS TYPE STRING,
MATID TYPE STRING,
HUTYPGRP TYPE STRING,
PROCTY TYPE STRING,
KIT_ACT TYPE STRING,
PL_START_TIME TYPE STRING,
PL_END_TIME TYPE STRING,
EFFORT_CODE TYPE STRING,
FIXED_QUAN TYPE STRING,
PLDURA TYPE STRING,
UNIT_T TYPE STRING,
DUMMY_VASA_DB TYPE STRING,
NUMBER_LAST_ITEM TYPE STRING,
NUMBER_LAST_AUXPROD TYPE STRING,
COMPLQTY_UI TYPE STRING,
PLANQTY_UI TYPE STRING,
PLAN_QTY_UOM TYPE STRING,
START_DATE TYPE STRING,
START_TIME TYPE STRING,
END_DATE TYPE STRING,
END_TIME TYPE STRING,
PLAN_QTY TYPE STRING,
PLAN_MATNR TYPE STRING,
PLAN_MAKTX TYPE STRING,
PROCS_DESC TYPE STRING,
LGNUM TYPE STRING,
CUST_BLOCKED TYPE STRING,
PLAN_START_DATE TYPE STRING,
PLAN_START_TIME TYPE STRING,
PLAN_END_DATE TYPE STRING,
PLAN_END_TIME TYPE STRING,
RDOCCAT TYPE STRING,
RDOCID TYPE STRING,
RITMID TYPE STRING,
POSTQTY TYPE STRING,
UI_POSTQTY TYPE STRING,
WRK_REL TYPE STRING,
LA_CODE TYPE STRING,
ITEMS TYPE STRING,
AUXPRODS TYPE STRING,
EWRKL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_VAS_ACT_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-ACTIVITY sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-VAS_GUID sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-ACT_GUID sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-ACT_SEQ sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PS_LEVEL sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-COMPLQTY sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-BASE_UNIT sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-STATUS sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-STARTED_AT sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-ENDED_AT sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-CHGUSR sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-CHGTST sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-WORKCENTER sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PROCS sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-MATID sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-HUTYPGRP sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PROCTY sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-KIT_ACT sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PL_START_TIME sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PL_END_TIME sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-EFFORT_CODE sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-FIXED_QUAN sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLDURA sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-UNIT_T sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-DUMMY_VASA_DB sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-NUMBER_LAST_ITEM sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-NUMBER_LAST_AUXPROD sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-COMPLQTY_UI sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLANQTY_UI sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_QTY_UOM sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-START_DATE sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-START_TIME sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-END_DATE sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-END_TIME sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_QTY sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_MATNR sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_MAKTX sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PROCS_DESC sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-LGNUM sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-CUST_BLOCKED sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_START_DATE sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_START_TIME sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_END_DATE sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-PLAN_END_TIME sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-RDOCCAT sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-RDOCID sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-RITMID sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-POSTQTY sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-UI_POSTQTY sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-WRK_REL sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-LA_CODE sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-ITEMS sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-AUXPRODS sy-vline
WA_/SCWM/S_VAS_ACT_INT_STR-EWRKL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.