ABAP Select data from SAP table /SCWM/V_ABC_WT_C into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/V_ABC_WT_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/V_ABC_WT_C. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/V_ABC_WT_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/V_ABC_WT_C TYPE STANDARD TABLE OF /SCWM/V_ABC_WT_C, WA_/SCWM/V_ABC_WT_C TYPE /SCWM/V_ABC_WT_C, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/V_ABC_WT_C> TYPE /SCWM/V_ABC_WT_C. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/V_ABC_WT_C. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/V_ABC_WT_C INTO TABLE IT_/SCWM/V_ABC_WT_C. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/V_ABC_WT_C * INTO TABLE @DATA(IT_/SCWM/V_ABC_WT_C2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/V_ABC_WT_C INDEX 1 INTO DATA(WA_/SCWM/V_ABC_WT_C2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/V_ABC_WT_C ASSIGNING </SCWM/V_ABC_WT_C>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/V_ABC_WT_C>-MANDT = 1.
</SCWM/V_ABC_WT_C>-LGNUM = 1.
</SCWM/V_ABC_WT_C>-TANUM = 1.
</SCWM/V_ABC_WT_C>-TAPOS = 1.
</SCWM/V_ABC_WT_C>-FLGHUTO = 1.
ENDLOOP. LOOP AT IT_/SCWM/V_ABC_WT_C INTO WA_/SCWM/V_ABC_WT_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/V_ABC_WT_C-PROCTY, sy-vline,
WA_/SCWM/V_ABC_WT_C-TRART, sy-vline,
WA_/SCWM/V_ABC_WT_C-TOSTAT, sy-vline,
WA_/SCWM/V_ABC_WT_C-MATID, sy-vline,
WA_/SCWM/V_ABC_WT_C-BATCHID, sy-vline,
WA_/SCWM/V_ABC_WT_C-CAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/V_ABC_WT_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/V_ABC_WT_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/V_ABC_WT_C INTO WA_/SCWM/V_ABC_WT_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPH0, internal->external for field TANUM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-TANUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-TANUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPH0, internal->external for field TAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-TAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-TAPOS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-MATID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-OWNER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-ENTITLED.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-ALTME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTWH, internal->external for field CONFIRMED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/V_ABC_WT_C-CONFIRMED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_ABC_WT_C-CONFIRMED_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/V_ABC_WT_C_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
TANUM TYPE STRING,
TAPOS TYPE STRING,
FLGHUTO TYPE STRING,
PROCTY TYPE STRING,
TRART TYPE STRING,
TOSTAT TYPE STRING,
MATID TYPE STRING,
BATCHID TYPE STRING,
CAT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_ITMNO TYPE STRING,
DOCCAT TYPE STRING,
STOCK_USAGE TYPE STRING,
OWNER TYPE STRING,
OWNER_ROLE TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_ROLE TYPE STRING,
STOCK_CNT TYPE STRING,
MEINS TYPE STRING,
ALTME TYPE STRING,
VSOLM TYPE STRING,
VSOLA TYPE STRING,
VLTYP TYPE STRING,
NLTYP TYPE STRING,
L2SKA TYPE STRING,
ORDIM_DUMMY TYPE STRING,
ZEUGN TYPE STRING,
CONFIRMED_AT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/V_ABC_WT_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/V_ABC_WT_C_STR-MANDT sy-vline
WA_/SCWM/V_ABC_WT_C_STR-LGNUM sy-vline
WA_/SCWM/V_ABC_WT_C_STR-TANUM sy-vline
WA_/SCWM/V_ABC_WT_C_STR-TAPOS sy-vline
WA_/SCWM/V_ABC_WT_C_STR-FLGHUTO sy-vline
WA_/SCWM/V_ABC_WT_C_STR-PROCTY sy-vline
WA_/SCWM/V_ABC_WT_C_STR-TRART sy-vline
WA_/SCWM/V_ABC_WT_C_STR-TOSTAT sy-vline
WA_/SCWM/V_ABC_WT_C_STR-MATID sy-vline
WA_/SCWM/V_ABC_WT_C_STR-BATCHID sy-vline
WA_/SCWM/V_ABC_WT_C_STR-CAT sy-vline
WA_/SCWM/V_ABC_WT_C_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/V_ABC_WT_C_STR-STOCK_DOCNO sy-vline
WA_/SCWM/V_ABC_WT_C_STR-STOCK_ITMNO sy-vline
WA_/SCWM/V_ABC_WT_C_STR-DOCCAT sy-vline
WA_/SCWM/V_ABC_WT_C_STR-STOCK_USAGE sy-vline
WA_/SCWM/V_ABC_WT_C_STR-OWNER sy-vline
WA_/SCWM/V_ABC_WT_C_STR-OWNER_ROLE sy-vline
WA_/SCWM/V_ABC_WT_C_STR-ENTITLED sy-vline
WA_/SCWM/V_ABC_WT_C_STR-ENTITLED_ROLE sy-vline
WA_/SCWM/V_ABC_WT_C_STR-STOCK_CNT sy-vline
WA_/SCWM/V_ABC_WT_C_STR-MEINS sy-vline
WA_/SCWM/V_ABC_WT_C_STR-ALTME sy-vline
WA_/SCWM/V_ABC_WT_C_STR-VSOLM sy-vline
WA_/SCWM/V_ABC_WT_C_STR-VSOLA sy-vline
WA_/SCWM/V_ABC_WT_C_STR-VLTYP sy-vline
WA_/SCWM/V_ABC_WT_C_STR-NLTYP sy-vline
WA_/SCWM/V_ABC_WT_C_STR-L2SKA sy-vline
WA_/SCWM/V_ABC_WT_C_STR-ORDIM_DUMMY sy-vline
WA_/SCWM/V_ABC_WT_C_STR-ZEUGN sy-vline
WA_/SCWM/V_ABC_WT_C_STR-CONFIRMED_AT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.