ABAP Select data from SAP table /SCWM/V_T329P into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/V_T329P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/V_T329P. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/V_T329P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/V_T329P TYPE STANDARD TABLE OF /SCWM/V_T329P, WA_/SCWM/V_T329P TYPE /SCWM/V_T329P, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/V_T329P> TYPE /SCWM/V_T329P. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/V_T329P. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/V_T329P INTO TABLE IT_/SCWM/V_T329P. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/V_T329P * INTO TABLE @DATA(IT_/SCWM/V_T329P2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/V_T329P INDEX 1 INTO DATA(WA_/SCWM/V_T329P2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/V_T329P ASSIGNING </SCWM/V_T329P>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/V_T329P>-MANDT = 1.
</SCWM/V_T329P>-LGNUM = 1.
</SCWM/V_T329P>-SPOOL = 1.
</SCWM/V_T329P>-TDDEST = 1.
</SCWM/V_T329P>-TDIMMED = 1.
ENDLOOP. LOOP AT IT_/SCWM/V_T329P INTO WA_/SCWM/V_T329P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/V_T329P-TDDELETE, sy-vline,
WA_/SCWM/V_T329P-TDNEWID, sy-vline,
WA_/SCWM/V_T329P-TDCOPIES, sy-vline,
WA_/SCWM/V_T329P-TDGROUP, sy-vline,
WA_/SCWM/V_T329P-TDDATASET, sy-vline,
WA_/SCWM/V_T329P-SUFFIX1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/V_T329P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/V_T329P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/V_T329P INTO WA_/SCWM/V_T329P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit SPDEV, internal->external for field TDDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_/SCWM/V_T329P-TDDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_T329P-TDDEST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/V_T329P_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
SPOOL TYPE STRING,
TDDEST TYPE STRING,
TDIMMED TYPE STRING,
TDDELETE TYPE STRING,
TDNEWID TYPE STRING,
TDCOPIES TYPE STRING,
TDGROUP TYPE STRING,
TDDATASET TYPE STRING,
SUFFIX1 TYPE STRING,
SUFFIX2 TYPE STRING,
COVER TYPE STRING,
RECIPIENT TYPE STRING,
DEPARTMENT TYPE STRING,
COVERTEXT TYPE STRING,
AUTHORIZTN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/V_T329P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/V_T329P_STR-MANDT sy-vline
WA_/SCWM/V_T329P_STR-LGNUM sy-vline
WA_/SCWM/V_T329P_STR-SPOOL sy-vline
WA_/SCWM/V_T329P_STR-TDDEST sy-vline
WA_/SCWM/V_T329P_STR-TDIMMED sy-vline
WA_/SCWM/V_T329P_STR-TDDELETE sy-vline
WA_/SCWM/V_T329P_STR-TDNEWID sy-vline
WA_/SCWM/V_T329P_STR-TDCOPIES sy-vline
WA_/SCWM/V_T329P_STR-TDGROUP sy-vline
WA_/SCWM/V_T329P_STR-TDDATASET sy-vline
WA_/SCWM/V_T329P_STR-SUFFIX1 sy-vline
WA_/SCWM/V_T329P_STR-SUFFIX2 sy-vline
WA_/SCWM/V_T329P_STR-COVER sy-vline
WA_/SCWM/V_T329P_STR-RECIPIENT sy-vline
WA_/SCWM/V_T329P_STR-DEPARTMENT sy-vline
WA_/SCWM/V_T329P_STR-COVERTEXT sy-vline
WA_/SCWM/V_T329P_STR-AUTHORIZTN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.