ABAP Select data from SAP table /SCWM/V_T343XYZ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/V_T343XYZ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/V_T343XYZ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/V_T343XYZ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/V_T343XYZ TYPE STANDARD TABLE OF /SCWM/V_T343XYZ,
      WA_/SCWM/V_T343XYZ TYPE /SCWM/V_T343XYZ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/V_T343XYZ> TYPE /SCWM/V_T343XYZ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/V_T343XYZ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/V_T343XYZ
  INTO TABLE IT_/SCWM/V_T343XYZ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/V_T343XYZ
*  INTO TABLE @DATA(IT_/SCWM/V_T343XYZ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/V_T343XYZ INDEX 1 INTO DATA(WA_/SCWM/V_T343XYZ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/V_T343XYZ ASSIGNING </SCWM/V_T343XYZ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/V_T343XYZ>-MANDT = 1.
</SCWM/V_T343XYZ>-LGNUM = 1.
</SCWM/V_T343XYZ>-LFDNR = 1.
</SCWM/V_T343XYZ>-LGTYP = 1.
</SCWM/V_T343XYZ>-LPTYP = 1.
ENDLOOP.

LOOP AT IT_/SCWM/V_T343XYZ INTO WA_/SCWM/V_T343XYZ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/V_T343XYZ-SCHAB, sy-vline,
WA_/SCWM/V_T343XYZ-STRUK, sy-vline,
WA_/SCWM/V_T343XYZ-STAWE, sy-vline,
WA_/SCWM/V_T343XYZ-ENDWE, sy-vline,
WA_/SCWM/V_T343XYZ-INCRE, sy-vline,
WA_/SCWM/V_T343XYZ-LGBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/V_T343XYZ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/V_T343XYZ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/V_T343XYZ INTO WA_/SCWM/V_T343XYZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/V_T343XYZ-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_T343XYZ-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/V_T343XYZ-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_T343XYZ-UNIT_V.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DIST_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/V_T343XYZ-DIST_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_T343XYZ-DIST_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field MAX_BIN_DEPTH CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/V_T343XYZ-MAX_BIN_DEPTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/V_T343XYZ-MAX_BIN_DEPTH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/V_T343XYZ_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
LFDNR TYPE STRING,
LGTYP TYPE STRING,
LPTYP TYPE STRING,
SCHAB TYPE STRING,
STRUK TYPE STRING,
STAWE TYPE STRING,
ENDWE TYPE STRING,
INCRE TYPE STRING,
LGBER TYPE STRING,
MAX_WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
MAX_VOLUME TYPE STRING,
UNIT_V TYPE STRING,
BRAND TYPE STRING,
MAX_CAPA TYPE STRING,
X_ZERO TYPE STRING,
Y_ZERO TYPE STRING,
Z_ZERO TYPE STRING,
X_INCR TYPE STRING,
Y_INCR TYPE STRING,
Z_INCR TYPE STRING,
ANGLE TYPE STRING,
LTYPT TYPE STRING,
LBERT TYPE STRING,
PTYPT TYPE STRING,
BRANT TYPE STRING,
BIN_AT TYPE STRING,
LNUMT TYPE STRING,
XINCX TYPE STRING,
XINCY TYPE STRING,
YINCX TYPE STRING,
YINCY TYPE STRING,
DIST_UOM TYPE STRING,
LGBER_LGST TYPE STRING,
X_IND TYPE STRING,
Y_IND TYPE STRING,
Z_IND TYPE STRING,
MAX_BIN_DEPTH TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/V_T343XYZ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/V_T343XYZ_STR-MANDT sy-vline
WA_/SCWM/V_T343XYZ_STR-LGNUM sy-vline
WA_/SCWM/V_T343XYZ_STR-LFDNR sy-vline
WA_/SCWM/V_T343XYZ_STR-LGTYP sy-vline
WA_/SCWM/V_T343XYZ_STR-LPTYP sy-vline
WA_/SCWM/V_T343XYZ_STR-SCHAB sy-vline
WA_/SCWM/V_T343XYZ_STR-STRUK sy-vline
WA_/SCWM/V_T343XYZ_STR-STAWE sy-vline
WA_/SCWM/V_T343XYZ_STR-ENDWE sy-vline
WA_/SCWM/V_T343XYZ_STR-INCRE sy-vline
WA_/SCWM/V_T343XYZ_STR-LGBER sy-vline
WA_/SCWM/V_T343XYZ_STR-MAX_WEIGHT sy-vline
WA_/SCWM/V_T343XYZ_STR-UNIT_W sy-vline
WA_/SCWM/V_T343XYZ_STR-MAX_VOLUME sy-vline
WA_/SCWM/V_T343XYZ_STR-UNIT_V sy-vline
WA_/SCWM/V_T343XYZ_STR-BRAND sy-vline
WA_/SCWM/V_T343XYZ_STR-MAX_CAPA sy-vline
WA_/SCWM/V_T343XYZ_STR-X_ZERO sy-vline
WA_/SCWM/V_T343XYZ_STR-Y_ZERO sy-vline
WA_/SCWM/V_T343XYZ_STR-Z_ZERO sy-vline
WA_/SCWM/V_T343XYZ_STR-X_INCR sy-vline
WA_/SCWM/V_T343XYZ_STR-Y_INCR sy-vline
WA_/SCWM/V_T343XYZ_STR-Z_INCR sy-vline
WA_/SCWM/V_T343XYZ_STR-ANGLE sy-vline
WA_/SCWM/V_T343XYZ_STR-LTYPT sy-vline
WA_/SCWM/V_T343XYZ_STR-LBERT sy-vline
WA_/SCWM/V_T343XYZ_STR-PTYPT sy-vline
WA_/SCWM/V_T343XYZ_STR-BRANT sy-vline
WA_/SCWM/V_T343XYZ_STR-BIN_AT sy-vline
WA_/SCWM/V_T343XYZ_STR-LNUMT sy-vline
WA_/SCWM/V_T343XYZ_STR-XINCX sy-vline
WA_/SCWM/V_T343XYZ_STR-XINCY sy-vline
WA_/SCWM/V_T343XYZ_STR-YINCX sy-vline
WA_/SCWM/V_T343XYZ_STR-YINCY sy-vline
WA_/SCWM/V_T343XYZ_STR-DIST_UOM sy-vline
WA_/SCWM/V_T343XYZ_STR-LGBER_LGST sy-vline
WA_/SCWM/V_T343XYZ_STR-X_IND sy-vline
WA_/SCWM/V_T343XYZ_STR-Y_IND sy-vline
WA_/SCWM/V_T343XYZ_STR-Z_IND sy-vline
WA_/SCWM/V_T343XYZ_STR-MAX_BIN_DEPTH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.