ABAP Select data from SAP table /SDF/DB6_700_ST04_VIEW_2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SDF/DB6_700_ST04_VIEW_2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SDF/DB6_700_ST04_VIEW_2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SDF/DB6_700_ST04_VIEW_2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SDF/DB6_700_ST04_VIEW_2 TYPE STANDARD TABLE OF /SDF/DB6_700_ST04_VIEW_2,
      WA_/SDF/DB6_700_ST04_VIEW_2 TYPE /SDF/DB6_700_ST04_VIEW_2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SDF/DB6_700_ST04_VIEW_2> TYPE /SDF/DB6_700_ST04_VIEW_2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SDF/DB6_700_ST04_VIEW_2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SDF/DB6_700_ST04_VIEW_2
  INTO TABLE IT_/SDF/DB6_700_ST04_VIEW_2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SDF/DB6_700_ST04_VIEW_2
*  INTO TABLE @DATA(IT_/SDF/DB6_700_ST04_VIEW_22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SDF/DB6_700_ST04_VIEW_2 INDEX 1 INTO DATA(WA_/SDF/DB6_700_ST04_VIEW_22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SDF/DB6_700_ST04_VIEW_2 ASSIGNING </SDF/DB6_700_ST04_VIEW_2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SDF/DB6_700_ST04_VIEW_2>-ANALYSIS_ID = 1.
</SDF/DB6_700_ST04_VIEW_2>-STMT_NUM = 1.
</SDF/DB6_700_ST04_VIEW_2>-STMT_ID = 1.
</SDF/DB6_700_ST04_VIEW_2>-STMT_TEXT = 1.
</SDF/DB6_700_ST04_VIEW_2>-NUM_EXECUTIONS = 1.
ENDLOOP.

LOOP AT IT_/SDF/DB6_700_ST04_VIEW_2 INTO WA_/SDF/DB6_700_ST04_VIEW_2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SDF/DB6_700_ST04_VIEW_2-TOTAL_EXEC_TIME_MILLISEC, sy-vline,
WA_/SDF/DB6_700_ST04_VIEW_2-TOTAL_EXEC_TIME_PC, sy-vline,
WA_/SDF/DB6_700_ST04_VIEW_2-AVERAGE_EXEC_TIME_MILLISEC, sy-vline,
WA_/SDF/DB6_700_ST04_VIEW_2-BUFFER_QUALITY_PC, sy-vline,
WA_/SDF/DB6_700_ST04_VIEW_2-ROWS_READ, sy-vline,
WA_/SDF/DB6_700_ST04_VIEW_2-ROWS_READ_PC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SDF/DB6_700_ST04_VIEW_2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SDF/DB6_700_ST04_VIEW_2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SDF/DB6_700_ST04_VIEW_2 INTO WA_/SDF/DB6_700_ST04_VIEW_2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SDF/DB6_700_ST04_VIEW_2_STR,
ANALYSIS_ID TYPE STRING,
STMT_NUM TYPE STRING,
STMT_ID TYPE STRING,
STMT_TEXT TYPE STRING,
NUM_EXECUTIONS TYPE STRING,
TOTAL_EXEC_TIME_MILLISEC TYPE STRING,
TOTAL_EXEC_TIME_PC TYPE STRING,
AVERAGE_EXEC_TIME_MILLISEC TYPE STRING,
BUFFER_QUALITY_PC TYPE STRING,
ROWS_READ TYPE STRING,
ROWS_READ_PC TYPE STRING,
ROWS_WRITTEN TYPE STRING,
ROWS_WRITTEN_PC TYPE STRING,
STMT_SORTS TYPE STRING,
SORT_OVERFLOWS TYPE STRING,
TOTAL_SORT_TIME TYPE STRING,
DBPARTITIONNUM TYPE STRING,
ABAP_SOURCE TYPE STRING,
ABAP_LINE TYPE STRING,
ROWS_RETURNED TYPE STRING,
ROWS_RETURNED_PC TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SDF/DB6_700_ST04_VIEW_2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ANALYSIS_ID sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-STMT_NUM sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-STMT_ID sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-STMT_TEXT sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-NUM_EXECUTIONS sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-TOTAL_EXEC_TIME_MILLISEC sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-TOTAL_EXEC_TIME_PC sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-AVERAGE_EXEC_TIME_MILLISEC sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-BUFFER_QUALITY_PC sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ROWS_READ sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ROWS_READ_PC sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ROWS_WRITTEN sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ROWS_WRITTEN_PC sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-STMT_SORTS sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-SORT_OVERFLOWS sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-TOTAL_SORT_TIME sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-DBPARTITIONNUM sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ABAP_SOURCE sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ABAP_LINE sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ROWS_RETURNED sy-vline
WA_/SDF/DB6_700_ST04_VIEW_2_STR-ROWS_RETURNED_PC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.