ABAP Select data from SAP table /SEHS/DGS_TRAIO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SEHS/DGS_TRAIO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SEHS/DGS_TRAIO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SEHS/DGS_TRAIO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SEHS/DGS_TRAIO TYPE STANDARD TABLE OF /SEHS/DGS_TRAIO, WA_/SEHS/DGS_TRAIO TYPE /SEHS/DGS_TRAIO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SEHS/DGS_TRAIO> TYPE /SEHS/DGS_TRAIO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SEHS/DGS_TRAIO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SEHS/DGS_TRAIO INTO TABLE IT_/SEHS/DGS_TRAIO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SEHS/DGS_TRAIO * INTO TABLE @DATA(IT_/SEHS/DGS_TRAIO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SEHS/DGS_TRAIO INDEX 1 INTO DATA(WA_/SEHS/DGS_TRAIO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SEHS/DGS_TRAIO ASSIGNING </SEHS/DGS_TRAIO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SEHS/DGS_TRAIO>-MARKFLG = 1.
</SEHS/DGS_TRAIO>-SELEFLG = 1.
</SEHS/DGS_TRAIO>-LINENO = 1.
</SEHS/DGS_TRAIO>-LINEMOD = 1.
</SEHS/DGS_TRAIO>-CHCOFLG = 1.
ENDLOOP. LOOP AT IT_/SEHS/DGS_TRAIO INTO WA_/SEHS/DGS_TRAIO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SEHS/DGS_TRAIO-LOCKMOD, sy-vline,
WA_/SEHS/DGS_TRAIO-INTRFLG, sy-vline,
WA_/SEHS/DGS_TRAIO-MANDT, sy-vline,
WA_/SEHS/DGS_TRAIO-RECN, sy-vline,
WA_/SEHS/DGS_TRAIO-ACTN, sy-vline,
WA_/SEHS/DGS_TRAIO-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SEHS/DGS_TRAIO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SEHS/DGS_TRAIO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SEHS/DGS_TRAIO INTO WA_/SEHS/DGS_TRAIO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SEHS/DGS_TRAIO-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SEHS/DGS_TRAIO-RECN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SEHS/DGS_TRAIO-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SEHS/DGS_TRAIO-ACTN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SEHS/DGS_TRAIO-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SEHS/DGS_TRAIO-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SEHS/DGS_TRAIO-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SEHS/DGS_TRAIO-OWNID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SEHS/DGS_TRAIO-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SEHS/DGS_TRAIO-RECNROOT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SEHS/DGS_TRAIO_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
SPPROV_PHRKEY TYPE STRING,
SP_PRINT_PHRKEY TYPE STRING,
MIX_PACK_PHRKEY TYPE STRING,
SEGREGAT_PHRKEY TYPE STRING,
PACKAGES_PHRKEY TYPE STRING,
BULK_PHRKEY TYPE STRING,
HANDLING_PHRKEY TYPE STRING,
OPERATION_PHRKEY TYPE STRING,
VEHICLE_PHRKEY TYPE STRING,
DAOR TYPE STRING,
SCREENFLAG TYPE STRING,
SPPROV_C TYPE STRING,
SPPROV_D TYPE STRING,
SP_PRINT_C TYPE STRING,
SP_PRINT_D TYPE STRING,
MIX_PACK_C TYPE STRING,
MIX_PACK_D TYPE STRING,
SEGREGAT_C TYPE STRING,
SEGREGAT_D TYPE STRING,
PACKAGES_C TYPE STRING,
PACKAGES_D TYPE STRING,
BULK_C TYPE STRING,
BULK_D TYPE STRING,
HANDLING_C TYPE STRING,
HANDLING_D TYPE STRING,
OPERATION_C TYPE STRING,
OPERATION_D TYPE STRING,
VEHICLE_C TYPE STRING,
VEHICLE_D TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SEHS/DGS_TRAIO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SEHS/DGS_TRAIO_STR-MARKFLG sy-vline
WA_/SEHS/DGS_TRAIO_STR-SELEFLG sy-vline
WA_/SEHS/DGS_TRAIO_STR-LINENO sy-vline
WA_/SEHS/DGS_TRAIO_STR-LINEMOD sy-vline
WA_/SEHS/DGS_TRAIO_STR-CHCOFLG sy-vline
WA_/SEHS/DGS_TRAIO_STR-LOCKMOD sy-vline
WA_/SEHS/DGS_TRAIO_STR-INTRFLG sy-vline
WA_/SEHS/DGS_TRAIO_STR-MANDT sy-vline
WA_/SEHS/DGS_TRAIO_STR-RECN sy-vline
WA_/SEHS/DGS_TRAIO_STR-ACTN sy-vline
WA_/SEHS/DGS_TRAIO_STR-VALFR sy-vline
WA_/SEHS/DGS_TRAIO_STR-VALTO sy-vline
WA_/SEHS/DGS_TRAIO_STR-AENNR sy-vline
WA_/SEHS/DGS_TRAIO_STR-DELFLG sy-vline
WA_/SEHS/DGS_TRAIO_STR-PARKFLG sy-vline
WA_/SEHS/DGS_TRAIO_STR-CRDAT sy-vline
WA_/SEHS/DGS_TRAIO_STR-CRNAM sy-vline
WA_/SEHS/DGS_TRAIO_STR-UPDDAT sy-vline
WA_/SEHS/DGS_TRAIO_STR-UPDNAM sy-vline
WA_/SEHS/DGS_TRAIO_STR-SRSID sy-vline
WA_/SEHS/DGS_TRAIO_STR-OWNID sy-vline
WA_/SEHS/DGS_TRAIO_STR-RECNROOT sy-vline
WA_/SEHS/DGS_TRAIO_STR-SPPROV_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-SP_PRINT_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-MIX_PACK_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-SEGREGAT_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-PACKAGES_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-BULK_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-HANDLING_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-OPERATION_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-VEHICLE_PHRKEY sy-vline
WA_/SEHS/DGS_TRAIO_STR-DAOR sy-vline
WA_/SEHS/DGS_TRAIO_STR-SCREENFLAG sy-vline
WA_/SEHS/DGS_TRAIO_STR-SPPROV_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-SPPROV_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-SP_PRINT_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-SP_PRINT_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-MIX_PACK_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-MIX_PACK_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-SEGREGAT_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-SEGREGAT_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-PACKAGES_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-PACKAGES_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-BULK_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-BULK_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-HANDLING_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-HANDLING_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-OPERATION_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-OPERATION_D sy-vline
WA_/SEHS/DGS_TRAIO_STR-VEHICLE_C sy-vline
WA_/SEHS/DGS_TRAIO_STR-VEHICLE_D sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.