ABAP Select data from SAP table /SRMSMC/S_BP_UI_GEN_QUAL_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SRMSMC/S_BP_UI_GEN_QUAL_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SRMSMC/S_BP_UI_GEN_QUAL_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SRMSMC/S_BP_UI_GEN_QUAL_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA TYPE STANDARD TABLE OF /SRMSMC/S_BP_UI_GEN_QUAL_DATA, WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA TYPE /SRMSMC/S_BP_UI_GEN_QUAL_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SRMSMC/S_BP_UI_GEN_QUAL_DATA> TYPE /SRMSMC/S_BP_UI_GEN_QUAL_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SRMSMC/S_BP_UI_GEN_QUAL_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SRMSMC/S_BP_UI_GEN_QUAL_DATA INTO TABLE IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SRMSMC/S_BP_UI_GEN_QUAL_DATA * INTO TABLE @DATA(IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA INDEX 1 INTO DATA(WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA ASSIGNING </SRMSMC/S_BP_UI_GEN_QUAL_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SRMSMC/S_BP_UI_GEN_QUAL_DATA>-VENDOR_FLG = 1.
</SRMSMC/S_BP_UI_GEN_QUAL_DATA>-BIDDER_FLG = 1.
</SRMSMC/S_BP_UI_GEN_QUAL_DATA>-POT_SUPPL_FLG = 1.
</SRMSMC/S_BP_UI_GEN_QUAL_DATA>-VENDOR_GROUP = 1.
</SRMSMC/S_BP_UI_GEN_QUAL_DATA>-DUNS_ID = 1.
ENDLOOP. LOOP AT IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA INTO WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA-ORDER_COLLAB, sy-vline,
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA-SELF_SERVICE, sy-vline,
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA-ABC_CLASS, sy-vline,
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA-CURRENCY, sy-vline,
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA-RESP_PURCHASER, sy-vline,
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA-SUPPLIER_AREA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SRMSMC/S_BP_UI_GEN_QUAL_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SRMSMC/S_BP_UI_GEN_QUAL_DATA INTO WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR,
VENDOR_FLG TYPE STRING,
BIDDER_FLG TYPE STRING,
POT_SUPPL_FLG TYPE STRING,
VENDOR_GROUP TYPE STRING,
DUNS_ID TYPE STRING,
ORDER_COLLAB TYPE STRING,
SELF_SERVICE TYPE STRING,
ABC_CLASS TYPE STRING,
CURRENCY TYPE STRING,
RESP_PURCHASER TYPE STRING,
SUPPLIER_AREA TYPE STRING,
SUPPLIER_ORIGIN TYPE STRING,
EVALUATION_SCORE TYPE STRING,
STRAT_IMPORTANCE TYPE STRING,
PREFERRED_SUPPL TYPE STRING,
STRAT_PARTNER TYPE STRING,
CUST_QUAL_LEVEL TYPE STRING,
DUMMY_EEW_CLCD TYPE STRING,
QUALIFICATION TYPE STRING,
STRATEGIC_IMPORTANCE_SL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-VENDOR_FLG sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-BIDDER_FLG sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-POT_SUPPL_FLG sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-VENDOR_GROUP sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-DUNS_ID sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-ORDER_COLLAB sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-SELF_SERVICE sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-ABC_CLASS sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-CURRENCY sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-RESP_PURCHASER sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-SUPPLIER_AREA sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-SUPPLIER_ORIGIN sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-EVALUATION_SCORE sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-STRAT_IMPORTANCE sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-PREFERRED_SUPPL sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-STRAT_PARTNER sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-CUST_QUAL_LEVEL sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-DUMMY_EEW_CLCD sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-QUALIFICATION sy-vline
WA_/SRMSMC/S_BP_UI_GEN_QUAL_DATA_STR-STRATEGIC_IMPORTANCE_SL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.