ABAP Select data from SAP table /SRMSMC/S_SEV_QS_ADVANCED into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SRMSMC/S_SEV_QS_ADVANCED table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SRMSMC/S_SEV_QS_ADVANCED. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SRMSMC/S_SEV_QS_ADVANCED table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SRMSMC/S_SEV_QS_ADVANCED TYPE STANDARD TABLE OF /SRMSMC/S_SEV_QS_ADVANCED, WA_/SRMSMC/S_SEV_QS_ADVANCED TYPE /SRMSMC/S_SEV_QS_ADVANCED, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SRMSMC/S_SEV_QS_ADVANCED> TYPE /SRMSMC/S_SEV_QS_ADVANCED. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SRMSMC/S_SEV_QS_ADVANCED. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SRMSMC/S_SEV_QS_ADVANCED INTO TABLE IT_/SRMSMC/S_SEV_QS_ADVANCED. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SRMSMC/S_SEV_QS_ADVANCED * INTO TABLE @DATA(IT_/SRMSMC/S_SEV_QS_ADVANCED2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SRMSMC/S_SEV_QS_ADVANCED INDEX 1 INTO DATA(WA_/SRMSMC/S_SEV_QS_ADVANCED2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SRMSMC/S_SEV_QS_ADVANCED ASSIGNING </SRMSMC/S_SEV_QS_ADVANCED>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SRMSMC/S_SEV_QS_ADVANCED>-ID = 1.
</SRMSMC/S_SEV_QS_ADVANCED>-NAME = 1.
</SRMSMC/S_SEV_QS_ADVANCED>-NAME_UPPER = 1.
</SRMSMC/S_SEV_QS_ADVANCED>-CREA_DATE_TIME = 1.
</SRMSMC/S_SEV_QS_ADVANCED>-CREA_UNAME = 1.
ENDLOOP. LOOP AT IT_/SRMSMC/S_SEV_QS_ADVANCED INTO WA_/SRMSMC/S_SEV_QS_ADVANCED. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SRMSMC/S_SEV_QS_ADVANCED-LCHG_DATE_TIME, sy-vline,
WA_/SRMSMC/S_SEV_QS_ADVANCED-LCHG_UNAME, sy-vline,
WA_/SRMSMC/S_SEV_QS_ADVANCED-PUC_KEY, sy-vline,
WA_/SRMSMC/S_SEV_QS_ADVANCED-EVAL_START_DATE, sy-vline,
WA_/SRMSMC/S_SEV_QS_ADVANCED-EVAL_END_DATE, sy-vline,
WA_/SRMSMC/S_SEV_QS_ADVANCED-DEADLINE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SRMSMC/S_SEV_QS_ADVANCED you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SRMSMC/S_SEV_QS_ADVANCED TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SRMSMC/S_SEV_QS_ADVANCED INTO WA_/SRMSMC/S_SEV_QS_ADVANCED. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SRMSMC/S_SEV_QS_ADVANCED-ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SRMSMC/S_SEV_QS_ADVANCED-ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field LANGUAGE_CODE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/SRMSMC/S_SEV_QS_ADVANCED-LANGUAGE_CODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SRMSMC/S_SEV_QS_ADVANCED-LANGUAGE_CODE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SRMSMC/S_SEV_QS_ADVANCED_STR,
ID TYPE STRING,
NAME TYPE STRING,
NAME_UPPER TYPE STRING,
CREA_DATE_TIME TYPE STRING,
CREA_UNAME TYPE STRING,
LCHG_DATE_TIME TYPE STRING,
LCHG_UNAME TYPE STRING,
PUC_KEY TYPE STRING,
EVAL_START_DATE TYPE STRING,
EVAL_END_DATE TYPE STRING,
DEADLINE TYPE STRING,
LANGUAGE_CODE TYPE STRING,
TRANS_STATUS TYPE STRING,
SES_INT_LENGTH TYPE STRING,
RES_DATE_DAYS TYPE STRING,
CONSISTENCY_STCD TYPE STRING,
LIFECYCLE_STCD TYPE STRING,
EVAL_PROCESS_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SRMSMC/S_SEV_QS_ADVANCED_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-ID sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-NAME sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-NAME_UPPER sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-CREA_DATE_TIME sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-CREA_UNAME sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-LCHG_DATE_TIME sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-LCHG_UNAME sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-PUC_KEY sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-EVAL_START_DATE sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-EVAL_END_DATE sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-DEADLINE sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-LANGUAGE_CODE sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-TRANS_STATUS sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-SES_INT_LENGTH sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-RES_DATE_DAYS sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-CONSISTENCY_STCD sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-LIFECYCLE_STCD sy-vline
WA_/SRMSMC/S_SEV_QS_ADVANCED_STR-EVAL_PROCESS_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.