ABAP Select data from SAP table /STTPEC/S_WHS_TEST_TBOX_FLDS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /STTPEC/S_WHS_TEST_TBOX_FLDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /STTPEC/S_WHS_TEST_TBOX_FLDS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /STTPEC/S_WHS_TEST_TBOX_FLDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/STTPEC/S_WHS_TEST_TBOX_FLDS TYPE STANDARD TABLE OF /STTPEC/S_WHS_TEST_TBOX_FLDS, WA_/STTPEC/S_WHS_TEST_TBOX_FLDS TYPE /STTPEC/S_WHS_TEST_TBOX_FLDS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </STTPEC/S_WHS_TEST_TBOX_FLDS> TYPE /STTPEC/S_WHS_TEST_TBOX_FLDS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/STTPEC/S_WHS_TEST_TBOX_FLDS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /STTPEC/S_WHS_TEST_TBOX_FLDS INTO TABLE IT_/STTPEC/S_WHS_TEST_TBOX_FLDS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /STTPEC/S_WHS_TEST_TBOX_FLDS * INTO TABLE @DATA(IT_/STTPEC/S_WHS_TEST_TBOX_FLDS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/STTPEC/S_WHS_TEST_TBOX_FLDS INDEX 1 INTO DATA(WA_/STTPEC/S_WHS_TEST_TBOX_FLDS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/STTPEC/S_WHS_TEST_TBOX_FLDS ASSIGNING </STTPEC/S_WHS_TEST_TBOX_FLDS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</STTPEC/S_WHS_TEST_TBOX_FLDS>-SCAN_OBJ = 1.
</STTPEC/S_WHS_TEST_TBOX_FLDS>-SCAN_OBJ_PARENT = 1.
</STTPEC/S_WHS_TEST_TBOX_FLDS>-BUSFUNC = 1.
</STTPEC/S_WHS_TEST_TBOX_FLDS>-DOCNUM = 1.
</STTPEC/S_WHS_TEST_TBOX_FLDS>-DOCPOS = 1.
ENDLOOP. LOOP AT IT_/STTPEC/S_WHS_TEST_TBOX_FLDS INTO WA_/STTPEC/S_WHS_TEST_TBOX_FLDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-DOCYEAR, sy-vline,
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-LOGSYS, sy-vline,
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-TRNCODE, sy-vline,
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-DOCTPE, sy-vline,
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-LGNUM, sy-vline,
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-PLANT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/STTPEC/S_WHS_TEST_TBOX_FLDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/STTPEC/S_WHS_TEST_TBOX_FLDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/STTPEC/S_WHS_TEST_TBOX_FLDS INTO WA_/STTPEC/S_WHS_TEST_TBOX_FLDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-LOGSYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-ENTITLED.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/STTPEC/S_WHS_TEST_TBOX_FLDS-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR,
SCAN_OBJ TYPE STRING,
SCAN_OBJ_PARENT TYPE STRING,
BUSFUNC TYPE STRING,
DOCNUM TYPE STRING,
DOCPOS TYPE STRING,
DOCYEAR TYPE STRING,
LOGSYS TYPE STRING,
TRNCODE TYPE STRING,
DOCTPE TYPE STRING,
LGNUM TYPE STRING,
PLANT TYPE STRING,
LGORT TYPE STRING,
LGTYP TYPE STRING,
LGPLA TYPE STRING,
ENTITLED TYPE STRING,
MATNR TYPE STRING,
UNIT TYPE STRING,
LOTNO TYPE STRING,
QTY_REQ TYPE STRING,
QTY_REM TYPE STRING,
UNIT_REM TYPE STRING,
SSCC TYPE STRING,
GCP TYPE STRING,
TOP_LVL TYPE STRING,
SSCC_PARENT TYPE STRING,
UNIT_PARENT TYPE STRING,
CHILD_REQ TYPE STRING,
CHILD_REM TYPE STRING,
SAMPLE_METHOD TYPE STRING,
CHILD_CNT TYPE STRING,
EVTACTION TYPE STRING,
CHILD_PCT TYPE STRING,
SKIP_VALIDATION TYPE STRING,
USETYPE TYPE STRING,
DOC_CHECK TYPE STRING,
SHIP_FR_LOC TYPE STRING,
SHIP_TO_LOC TYPE STRING,
SOLD_FR_LOC TYPE STRING,
SOLD_TO_LOC TYPE STRING,
LONGITUDE TYPE STRING,
LATITUDE TYPE STRING,
LANGU TYPE STRING,
ATT_SYSTEM_NAME TYPE STRING,
SCAN_OBJ_1_RESULT TYPE STRING,
SCAN_OBJ_2_RESULT TYPE STRING,
SCAN_OBJ_1_DESCR TYPE STRING,
SCAN_OBJ_2_DESCR TYPE STRING,
USE_NESTED TYPE STRING,END OF T_EKKO_STR. DATA: WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SCAN_OBJ sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SCAN_OBJ_PARENT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-BUSFUNC sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-DOCNUM sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-DOCPOS sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-DOCYEAR sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LOGSYS sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-TRNCODE sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-DOCTPE sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LGNUM sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-PLANT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LGORT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LGTYP sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LGPLA sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-ENTITLED sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-MATNR sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-UNIT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LOTNO sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-QTY_REQ sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-QTY_REM sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-UNIT_REM sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SSCC sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-GCP sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-TOP_LVL sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SSCC_PARENT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-UNIT_PARENT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-CHILD_REQ sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-CHILD_REM sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SAMPLE_METHOD sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-CHILD_CNT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-EVTACTION sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-CHILD_PCT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SKIP_VALIDATION sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-USETYPE sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-DOC_CHECK sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SHIP_FR_LOC sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SHIP_TO_LOC sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SOLD_FR_LOC sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SOLD_TO_LOC sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LONGITUDE sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LATITUDE sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-LANGU sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-ATT_SYSTEM_NAME sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SCAN_OBJ_1_RESULT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SCAN_OBJ_2_RESULT sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SCAN_OBJ_1_DESCR sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-SCAN_OBJ_2_DESCR sy-vline
WA_/STTPEC/S_WHS_TEST_TBOX_FLDS_STR-USE_NESTED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.