ABAP Select data from SAP table /SYCLO/CA000_CBC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SYCLO/CA000_CBC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SYCLO/CA000_CBC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SYCLO/CA000_CBC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SYCLO/CA000_CBC TYPE STANDARD TABLE OF /SYCLO/CA000_CBC,
      WA_/SYCLO/CA000_CBC TYPE /SYCLO/CA000_CBC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SYCLO/CA000_CBC> TYPE /SYCLO/CA000_CBC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SYCLO/CA000_CBC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SYCLO/CA000_CBC
  INTO TABLE IT_/SYCLO/CA000_CBC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SYCLO/CA000_CBC
*  INTO TABLE @DATA(IT_/SYCLO/CA000_CBC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SYCLO/CA000_CBC INDEX 1 INTO DATA(WA_/SYCLO/CA000_CBC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SYCLO/CA000_CBC ASSIGNING </SYCLO/CA000_CBC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SYCLO/CA000_CBC>-MOBILE_APP = 1.
</SYCLO/CA000_CBC>-TYPE = 1.
</SYCLO/CA000_CBC>-VERSION = 1.
</SYCLO/CA000_CBC>-DESCRIPTION = 1.
</SYCLO/CA000_CBC>-AUTO_CRT_OFF = 1.
ENDLOOP.

LOOP AT IT_/SYCLO/CA000_CBC INTO WA_/SYCLO/CA000_CBC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SYCLO/CA000_CBC-SERVER_REG_OFF, sy-vline,
WA_/SYCLO/CA000_CBC-MULTI_BACKEND, sy-vline,
WA_/SYCLO/CA000_CBC-SYSTEM_ROLE, sy-vline,
WA_/SYCLO/CA000_CBC-FLAG_BLOCKED, sy-vline,
WA_/SYCLO/CA000_CBC-EFFECTIVE_TS, sy-vline,
WA_/SYCLO/CA000_CBC-DISABLE_EXOBJ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SYCLO/CA000_CBC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SYCLO/CA000_CBC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SYCLO/CA000_CBC INTO WA_/SYCLO/CA000_CBC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SYCLO/CA000_CBC_STR,
MOBILE_APP TYPE STRING,
TYPE TYPE STRING,
VERSION TYPE STRING,
DESCRIPTION TYPE STRING,
AUTO_CRT_OFF TYPE STRING,
SERVER_REG_OFF TYPE STRING,
MULTI_BACKEND TYPE STRING,
SYSTEM_ROLE TYPE STRING,
FLAG_BLOCKED TYPE STRING,
EFFECTIVE_TS TYPE STRING,
DISABLE_EXOBJ TYPE STRING,
ENABLE_IBQ TYPE STRING,
STD_IBQ_QUEUE_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SYCLO/CA000_CBC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SYCLO/CA000_CBC_STR-MOBILE_APP sy-vline
WA_/SYCLO/CA000_CBC_STR-TYPE sy-vline
WA_/SYCLO/CA000_CBC_STR-VERSION sy-vline
WA_/SYCLO/CA000_CBC_STR-DESCRIPTION sy-vline
WA_/SYCLO/CA000_CBC_STR-AUTO_CRT_OFF sy-vline
WA_/SYCLO/CA000_CBC_STR-SERVER_REG_OFF sy-vline
WA_/SYCLO/CA000_CBC_STR-MULTI_BACKEND sy-vline
WA_/SYCLO/CA000_CBC_STR-SYSTEM_ROLE sy-vline
WA_/SYCLO/CA000_CBC_STR-FLAG_BLOCKED sy-vline
WA_/SYCLO/CA000_CBC_STR-EFFECTIVE_TS sy-vline
WA_/SYCLO/CA000_CBC_STR-DISABLE_EXOBJ sy-vline
WA_/SYCLO/CA000_CBC_STR-ENABLE_IBQ sy-vline
WA_/SYCLO/CA000_CBC_STR-STD_IBQ_QUEUE_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.