ABAP Select data from SAP table /SYCLO/CORE_MSG_HDR_INFO1_STR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SYCLO/CORE_MSG_HDR_INFO1_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SYCLO/CORE_MSG_HDR_INFO1_STR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SYCLO/CORE_MSG_HDR_INFO1_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SYCLO/CORE_MSG_HDR_INFO1_STR TYPE STANDARD TABLE OF /SYCLO/CORE_MSG_HDR_INFO1_STR, WA_/SYCLO/CORE_MSG_HDR_INFO1_STR TYPE /SYCLO/CORE_MSG_HDR_INFO1_STR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SYCLO/CORE_MSG_HDR_INFO1_STR> TYPE /SYCLO/CORE_MSG_HDR_INFO1_STR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SYCLO/CORE_MSG_HDR_INFO1_STR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SYCLO/CORE_MSG_HDR_INFO1_STR INTO TABLE IT_/SYCLO/CORE_MSG_HDR_INFO1_STR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SYCLO/CORE_MSG_HDR_INFO1_STR * INTO TABLE @DATA(IT_/SYCLO/CORE_MSG_HDR_INFO1_STR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SYCLO/CORE_MSG_HDR_INFO1_STR INDEX 1 INTO DATA(WA_/SYCLO/CORE_MSG_HDR_INFO1_STR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SYCLO/CORE_MSG_HDR_INFO1_STR ASSIGNING </SYCLO/CORE_MSG_HDR_INFO1_STR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SYCLO/CORE_MSG_HDR_INFO1_STR>-STORAGE_GUID = 1.
</SYCLO/CORE_MSG_HDR_INFO1_STR>-MESSAGE_STATUS = 1.
</SYCLO/CORE_MSG_HDR_INFO1_STR>-CONFIRMATION_TS = 1.
</SYCLO/CORE_MSG_HDR_INFO1_STR>-READ_TS = 1.
</SYCLO/CORE_MSG_HDR_INFO1_STR>-SEND_TS = 1.
ENDLOOP. LOOP AT IT_/SYCLO/CORE_MSG_HDR_INFO1_STR INTO WA_/SYCLO/CORE_MSG_HDR_INFO1_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SYCLO/CORE_MSG_HDR_INFO1_STR-RECEIVED_TS, sy-vline,
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR-ORI_SESSION_GUID, sy-vline,
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR-CONFIRMED_FLAG, sy-vline,
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR-READ_FLAG, sy-vline,
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR-SEND_FLAG, sy-vline,
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR-RECEIVED_FLAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SYCLO/CORE_MSG_HDR_INFO1_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SYCLO/CORE_MSG_HDR_INFO1_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SYCLO/CORE_MSG_HDR_INFO1_STR INTO WA_/SYCLO/CORE_MSG_HDR_INFO1_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR,
STORAGE_GUID TYPE STRING,
MESSAGE_STATUS TYPE STRING,
CONFIRMATION_TS TYPE STRING,
READ_TS TYPE STRING,
SEND_TS TYPE STRING,
RECEIVED_TS TYPE STRING,
ORI_SESSION_GUID TYPE STRING,
CONFIRMED_FLAG TYPE STRING,
READ_FLAG TYPE STRING,
SEND_FLAG TYPE STRING,
RECEIVED_FLAG TYPE STRING,
MSG_REF_KEY TYPE STRING,
SCENARIO_ID TYPE STRING,
MESSAGE_DATA TYPE STRING,
ENABLE_OTRIG TYPE STRING,
ALLOW_RETRY TYPE STRING,
OTRIG_PROC_ID TYPE STRING,
OTRIG_PROC_TS TYPE STRING,
RETRY_COUNT TYPE STRING,
REFETCH_INTERVAL TYPE STRING,
FETCH_CALLBACK TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-STORAGE_GUID sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-MESSAGE_STATUS sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-CONFIRMATION_TS sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-READ_TS sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-SEND_TS sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-RECEIVED_TS sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-ORI_SESSION_GUID sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-CONFIRMED_FLAG sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-READ_FLAG sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-SEND_FLAG sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-RECEIVED_FLAG sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-MSG_REF_KEY sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-SCENARIO_ID sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-MESSAGE_DATA sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-ENABLE_OTRIG sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-ALLOW_RETRY sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-OTRIG_PROC_ID sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-OTRIG_PROC_TS sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-RETRY_COUNT sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-REFETCH_INTERVAL sy-vline
WA_/SYCLO/CORE_MSG_HDR_INFO1_STR_STR-FETCH_CALLBACK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.