ABAP Select data from SAP table /SYCLO/CORE_SUBQ_LIST_STR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SYCLO/CORE_SUBQ_LIST_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SYCLO/CORE_SUBQ_LIST_STR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SYCLO/CORE_SUBQ_LIST_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SYCLO/CORE_SUBQ_LIST_STR TYPE STANDARD TABLE OF /SYCLO/CORE_SUBQ_LIST_STR, WA_/SYCLO/CORE_SUBQ_LIST_STR TYPE /SYCLO/CORE_SUBQ_LIST_STR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SYCLO/CORE_SUBQ_LIST_STR> TYPE /SYCLO/CORE_SUBQ_LIST_STR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SYCLO/CORE_SUBQ_LIST_STR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SYCLO/CORE_SUBQ_LIST_STR INTO TABLE IT_/SYCLO/CORE_SUBQ_LIST_STR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SYCLO/CORE_SUBQ_LIST_STR * INTO TABLE @DATA(IT_/SYCLO/CORE_SUBQ_LIST_STR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SYCLO/CORE_SUBQ_LIST_STR INDEX 1 INTO DATA(WA_/SYCLO/CORE_SUBQ_LIST_STR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SYCLO/CORE_SUBQ_LIST_STR ASSIGNING </SYCLO/CORE_SUBQ_LIST_STR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SYCLO/CORE_SUBQ_LIST_STR>-MANDT = 1.
</SYCLO/CORE_SUBQ_LIST_STR>-SUB_REQ_GUID = 1.
</SYCLO/CORE_SUBQ_LIST_STR>-RECORD_ID = 1.
</SYCLO/CORE_SUBQ_LIST_STR>-MOBILE_APP = 1.
</SYCLO/CORE_SUBQ_LIST_STR>-SCENARIO_ID = 1.
ENDLOOP. LOOP AT IT_/SYCLO/CORE_SUBQ_LIST_STR INTO WA_/SYCLO/CORE_SUBQ_LIST_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SYCLO/CORE_SUBQ_LIST_STR-OBJKEY, sy-vline,
WA_/SYCLO/CORE_SUBQ_LIST_STR-OBJKEY_REF, sy-vline,
WA_/SYCLO/CORE_SUBQ_LIST_STR-SUBSCR_USER_GUID, sy-vline,
WA_/SYCLO/CORE_SUBQ_LIST_STR-SUBSCR_USER_ID, sy-vline,
WA_/SYCLO/CORE_SUBQ_LIST_STR-BEGIN_TS, sy-vline,
WA_/SYCLO/CORE_SUBQ_LIST_STR-REQBY_USER_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SYCLO/CORE_SUBQ_LIST_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SYCLO/CORE_SUBQ_LIST_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SYCLO/CORE_SUBQ_LIST_STR INTO WA_/SYCLO/CORE_SUBQ_LIST_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SYCLO/CORE_SUBQ_LIST_STR_STR,
MANDT TYPE STRING,
SUB_REQ_GUID TYPE STRING,
RECORD_ID TYPE STRING,
MOBILE_APP TYPE STRING,
SCENARIO_ID TYPE STRING,
OBJKEY TYPE STRING,
OBJKEY_REF TYPE STRING,
SUBSCR_USER_GUID TYPE STRING,
SUBSCR_USER_ID TYPE STRING,
BEGIN_TS TYPE STRING,
REQBY_USER_ID TYPE STRING,
VALIDITY TYPE STRING,
INSTANCE_GUID TYPE STRING,
STATUS TYPE STRING,
SUBAGENT_ID TYPE STRING,
MAX_DELIVERY TYPE STRING,
DELIVERY_COUNT TYPE STRING,
END_TS TYPE STRING,
DELIVERY_TS TYPE STRING,
FLAG_COMPLETED TYPE STRING,
FLAG_BLOCKED TYPE STRING,
FLAG_CANCEL TYPE STRING,
COMPLETED_TS TYPE STRING,
BLOCKED_TS TYPE STRING,
CANCEL_TS TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_TS TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_TS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SYCLO/CORE_SUBQ_LIST_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-MANDT sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-SUB_REQ_GUID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-RECORD_ID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-MOBILE_APP sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-SCENARIO_ID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-OBJKEY sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-OBJKEY_REF sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-SUBSCR_USER_GUID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-SUBSCR_USER_ID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-BEGIN_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-REQBY_USER_ID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-VALIDITY sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-INSTANCE_GUID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-STATUS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-SUBAGENT_ID sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-MAX_DELIVERY sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-DELIVERY_COUNT sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-END_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-DELIVERY_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-FLAG_COMPLETED sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-FLAG_BLOCKED sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-FLAG_CANCEL sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-COMPLETED_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-BLOCKED_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-CANCEL_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-CREATED_BY sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-CREATED_TS sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-CHANGED_BY sy-vline
WA_/SYCLO/CORE_SUBQ_LIST_STR_STR-CHANGED_TS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.