ABAP Select data from SAP table /SYCLO/VIAFVC_V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SYCLO/VIAFVC_V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SYCLO/VIAFVC_V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SYCLO/VIAFVC_V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SYCLO/VIAFVC_V TYPE STANDARD TABLE OF /SYCLO/VIAFVC_V,
      WA_/SYCLO/VIAFVC_V TYPE /SYCLO/VIAFVC_V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SYCLO/VIAFVC_V> TYPE /SYCLO/VIAFVC_V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SYCLO/VIAFVC_V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SYCLO/VIAFVC_V
  INTO TABLE IT_/SYCLO/VIAFVC_V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SYCLO/VIAFVC_V
*  INTO TABLE @DATA(IT_/SYCLO/VIAFVC_V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SYCLO/VIAFVC_V INDEX 1 INTO DATA(WA_/SYCLO/VIAFVC_V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SYCLO/VIAFVC_V ASSIGNING </SYCLO/VIAFVC_V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SYCLO/VIAFVC_V>-MANDT = 1.
</SYCLO/VIAFVC_V>-AUFNR = 1.
</SYCLO/VIAFVC_V>-AUFPL = 1.
</SYCLO/VIAFVC_V>-APLZL = 1.
</SYCLO/VIAFVC_V>-TPLNR = 1.
ENDLOOP.

LOOP AT IT_/SYCLO/VIAFVC_V INTO WA_/SYCLO/VIAFVC_V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SYCLO/VIAFVC_V-STRNO, sy-vline,
WA_/SYCLO/VIAFVC_V-AUTYP, sy-vline,
WA_/SYCLO/VIAFVC_V-REFNR, sy-vline,
WA_/SYCLO/VIAFVC_V-ERNAM, sy-vline,
WA_/SYCLO/VIAFVC_V-ERDAT, sy-vline,
WA_/SYCLO/VIAFVC_V-AENAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SYCLO/VIAFVC_V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SYCLO/VIAFVC_V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SYCLO/VIAFVC_V INTO WA_/SYCLO/VIAFVC_V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field STRNO CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-STRNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-STRNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-REFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-REFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-KOSTV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-KOSTV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CYCLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-CYCLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-CYCLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SCOPE, internal->external for field SCOPE CALL FUNCTION 'CONVERSION_EXIT_SCOPE_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SCOPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SCOPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SIZECL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SIZECL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SIZECL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNRA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-ADRNRA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-ADRNRA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-RECID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-RECID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ETYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-ETYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-ETYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-OTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-OTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CPD_UPDAT CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-CPD_UPDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-CPD_UPDAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field /CUM/CMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-/CUM/CMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-/CUM/CMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field /CUM/DESNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-/CUM/DESNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-/CUM/DESNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FERC_IND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-FERC_IND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-FERC_IND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-GMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-GMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PLNBEZ CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PLNBEZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PLNBEZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLNME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PLNME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PLNME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PAENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PAENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PAENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field STLBEZ CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-STLBEZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-STLBEZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SBMEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SBMEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SBMEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SAENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SAENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-AUFNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-AUFNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PRONR CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PRONR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PRONR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRUEFLOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PRUEFLOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PRUEFLOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-MAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-MAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LEAD_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-LEAD_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-LEAD_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PROID CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-PROID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-PROID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-ANLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-ANLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLUN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-ANLUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-ANLUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-DAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-DAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR_ILOA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-ADRNR_ILOA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-ADRNR_ILOA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BANFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-BANFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-BANFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field V_ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-V_ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-V_ISTRU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUNE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-DAUNE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-DAUNE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-DAUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-DAUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARBEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-ARBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-ARBEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-KUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GAUEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-GAUEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-GAUEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WARPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-WARPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-WARPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-WAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-LAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-LAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SERIALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SERIALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SERMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SERMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SERMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAINTORDPERSONRESPONSIBLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-MAINTORDPERSONRESPONSIBLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-MAINTORDPERSONRESPONSIBLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SERVICE_DOC_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SYCLO/VIAFVC_V-SERVICE_DOC_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SYCLO/VIAFVC_V-SERVICE_DOC_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SYCLO/VIAFVC_V_STR,
MANDT TYPE STRING,
AUFNR TYPE STRING,
AUFPL TYPE STRING,
APLZL TYPE STRING,
TPLNR TYPE STRING,
STRNO TYPE STRING,
AUTYP TYPE STRING,
REFNR TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
KTEXT TYPE STRING,
LTEXT TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
CCKEY TYPE STRING,
KOSTV TYPE STRING,
SOWRK TYPE STRING,
ASTKZ TYPE STRING,
WAERS TYPE STRING,
ASTNR TYPE STRING,
STDAT TYPE STRING,
ESTNR TYPE STRING,
PDAT1 TYPE STRING,
PDAT2 TYPE STRING,
PDAT3 TYPE STRING,
IDAT1 TYPE STRING,
IDAT2 TYPE STRING,
IDAT3 TYPE STRING,
OBJID TYPE STRING,
VOGRP TYPE STRING,
LOEKZ TYPE STRING,
PLGKZ TYPE STRING,
KVEWE TYPE STRING,
KAPPL TYPE STRING,
KALSM TYPE STRING,
ZSCHL TYPE STRING,
ABKRS TYPE STRING,
KSTAR TYPE STRING,
SAKNR TYPE STRING,
SETNM TYPE STRING,
CYCLE TYPE STRING,
SDATE TYPE STRING,
SEQNR TYPE STRING,
USER2 TYPE STRING,
USER4 TYPE STRING,
OBJNR TYPE STRING,
PRCTR TYPE STRING,
PSPEL TYPE STRING,
AWSLS TYPE STRING,
ABGSL TYPE STRING,
EB_POST TYPE STRING,
TXJCD TYPE STRING,
FUNC_AREA TYPE STRING,
SCOPE TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
IVPRO TYPE STRING,
ABUKR TYPE STRING,
SIZECL TYPE STRING,
IZWEK TYPE STRING,
UMWKZ TYPE STRING,
RSORD TYPE STRING,
BEMOT TYPE STRING,
ADRNRA TYPE STRING,
ERFZEIT TYPE STRING,
AEZEIT TYPE STRING,
CSTG_VRNT TYPE STRING,
COSTESTNR TYPE STRING,
VERAA_USER TYPE STRING,
EEW_AUFK_PS_DUMMY TYPE STRING,
VNAME TYPE STRING,
RECID TYPE STRING,
ETYPE TYPE STRING,
OTYPE TYPE STRING,
JV_JIBCL TYPE STRING,
JV_JIBSA TYPE STRING,
JV_OCO TYPE STRING,
CPD_UPDAT TYPE STRING,
/CUM/INDCU TYPE STRING,
/CUM/CMNUM TYPE STRING,
/CUM/AUEST TYPE STRING,
/CUM/DESNUM TYPE STRING,
AD01PROFNR TYPE STRING,
VAPLZ TYPE STRING,
WAWRK TYPE STRING,
FERC_IND TYPE STRING,
CLAIM_CONTROL TYPE STRING,
UPDATE_NEEDED TYPE STRING,
UPDATE_CONTROL TYPE STRING,
GLTRP TYPE STRING,
GSTRP TYPE STRING,
FTRMS TYPE STRING,
GLTRS TYPE STRING,
GSTRS TYPE STRING,
GSTRI TYPE STRING,
GETRI TYPE STRING,
GLTRI TYPE STRING,
FTRMI TYPE STRING,
FTRMP TYPE STRING,
RSNUM TYPE STRING,
GASMG TYPE STRING,
GAMNG TYPE STRING,
GMEIN TYPE STRING,
PLNBEZ TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAW TYPE STRING,
PLNAL TYPE STRING,
PVERW TYPE STRING,
PLAUF TYPE STRING,
PLSVB TYPE STRING,
PLNME TYPE STRING,
PLSVN TYPE STRING,
PDATV TYPE STRING,
PAENR TYPE STRING,
PLGRP TYPE STRING,
LODIV TYPE STRING,
STLTY TYPE STRING,
STLBEZ TYPE STRING,
STLST TYPE STRING,
STLNR TYPE STRING,
SDATV TYPE STRING,
SBMNG TYPE STRING,
SBMEH TYPE STRING,
SAENR TYPE STRING,
STLAL TYPE STRING,
STLAN TYPE STRING,
SLSVN TYPE STRING,
SLSBS TYPE STRING,
AUFLD TYPE STRING,
DISPO TYPE STRING,
FEVOR TYPE STRING,
FHORI TYPE STRING,
TERKZ TYPE STRING,
REDKZ TYPE STRING,
APRIO TYPE STRING,
AUFNT TYPE STRING,
AUFPT TYPE STRING,
APLZT TYPE STRING,
PROFID TYPE STRING,
VORGZ TYPE STRING,
SICHZ TYPE STRING,
FREIZ TYPE STRING,
UPTER TYPE STRING,
BEDID TYPE STRING,
PRONR TYPE STRING,
ZAEHL TYPE STRING,
MZAEHL TYPE STRING,
ZKRIZ TYPE STRING,
PRUEFLOS TYPE STRING,
KLVARP TYPE STRING,
KLVARI TYPE STRING,
RGEKZ TYPE STRING,
PLART TYPE STRING,
MAUFNR TYPE STRING,
LEAD_AUFNR TYPE STRING,
GLUZP TYPE STRING,
GSUZP TYPE STRING,
GLUZS TYPE STRING,
GSUZS TYPE STRING,
GEUZI TYPE STRING,
GSUZI TYPE STRING,
NO_DISP TYPE STRING,
STORT TYPE STRING,
KOSTL TYPE STRING,
ABCKZ TYPE STRING,
EQFNR TYPE STRING,
SWERK TYPE STRING,
MSGRP TYPE STRING,
BEBER TYPE STRING,
CR_OBJTY TYPE STRING,
PPSID TYPE STRING,
PROID TYPE STRING,
ANLNR TYPE STRING,
ANLUN TYPE STRING,
DAUFN TYPE STRING,
OWNER TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
ADRNR_ILOA TYPE STRING,
VORNR TYPE STRING,
STEUS TYPE STRING,
ARBID TYPE STRING,
V_WERKS TYPE STRING,
KTSCH TYPE STRING,
LTXA1 TYPE STRING,
LOANZ TYPE STRING,
LOART TYPE STRING,
RSANZ TYPE STRING,
QUALF TYPE STRING,
ANZMA TYPE STRING,
LOGRP TYPE STRING,
SUMNR TYPE STRING,
LIFNR TYPE STRING,
PREIS TYPE STRING,
PEINH TYPE STRING,
SAKTO TYPE STRING,
V_WAERS TYPE STRING,
INFNR TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
MATKL TYPE STRING,
ANZZL TYPE STRING,
PRZNT TYPE STRING,
INDET TYPE STRING,
LARNT TYPE STRING,
RUECK TYPE STRING,
RMZHL TYPE STRING,
V_OBJNR TYPE STRING,
BANFN TYPE STRING,
BNFPO TYPE STRING,
SELKZ TYPE STRING,
V_ANLZU TYPE STRING,
V_ISTRU TYPE STRING,
EBORT TYPE STRING,
ABLAD TYPE STRING,
WEMPF TYPE STRING,
PERNR TYPE STRING,
TXTSP TYPE STRING,
PHFLG TYPE STRING,
MEINH TYPE STRING,
DAUNO TYPE STRING,
DAUNE TYPE STRING,
DAUMI TYPE STRING,
DAUME TYPE STRING,
EINSA TYPE STRING,
EINSE TYPE STRING,
ARBEI TYPE STRING,
ARBEH TYPE STRING,
ISMNW TYPE STRING,
FSAVD TYPE STRING,
FSAVZ TYPE STRING,
FSEDD TYPE STRING,
FSEDZ TYPE STRING,
SSAVD TYPE STRING,
SSAVZ TYPE STRING,
SSEDD TYPE STRING,
SSEDZ TYPE STRING,
ISDD TYPE STRING,
ISDZ TYPE STRING,
IEDD TYPE STRING,
IEDZ TYPE STRING,
PUFFR TYPE STRING,
PUFGS TYPE STRING,
NTANF TYPE STRING,
NTANZ TYPE STRING,
NTEND TYPE STRING,
NTENZ TYPE STRING,
OFMNW TYPE STRING,
AUFKT TYPE STRING,
BUKRS TYPE STRING,
AUART TYPE STRING,
IWERK TYPE STRING,
INGPR TYPE STRING,
GEWRK TYPE STRING,
IPHAS TYPE STRING,
ARTPR TYPE STRING,
PRIOK TYPE STRING,
EQUNR TYPE STRING,
BAUTL TYPE STRING,
ILOAN TYPE STRING,
ILOAI TYPE STRING,
ANLZU TYPE STRING,
APGRP TYPE STRING,
PM_OBJTY TYPE STRING,
KUNUM TYPE STRING,
ANING TYPE STRING,
GAUZT TYPE STRING,
GAUEH TYPE STRING,
ANLBD TYPE STRING,
ANLVD TYPE STRING,
ANLBZ TYPE STRING,
ANLVZ TYPE STRING,
INSPK TYPE STRING,
DATAN TYPE STRING,
WARPL TYPE STRING,
ABNUM TYPE STRING,
WAPOS TYPE STRING,
LAUFN TYPE STRING,
OBKNR TYPE STRING,
REVNR TYPE STRING,
ADDAT TYPE STRING,
ADUHR TYPE STRING,
ILART TYPE STRING,
QMNUM TYPE STRING,
HISDA TYPE STRING,
AKKNZ TYPE STRING,
PLKNZ TYPE STRING,
SERIALNR TYPE STRING,
SERMAT TYPE STRING,
DEVICEID TYPE STRING,
SCREENTY TYPE STRING,
ADPSP TYPE STRING,
RSUPG TYPE STRING,
CHANGEDDATETIME TYPE STRING,
MAINTORDPERSONRESPONSIBLE TYPE STRING,
MAINTORDOVRLPROCPHASE TYPE STRING,
MAINTORDOVRLPROCSUBPHASE TYPE STRING,
DATAMODELVERSION TYPE STRING,
SERVICE_DOC_TYPE TYPE STRING,
SERVICE_DOC_ID TYPE STRING,
SERVICE_DOC_ITEM_ID TYPE STRING,
IS_BILLABLE TYPE STRING,
FLDLOGSDELIVISHELDONSHORE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SYCLO/VIAFVC_V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SYCLO/VIAFVC_V_STR-MANDT sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUFPL sy-vline
WA_/SYCLO/VIAFVC_V_STR-APLZL sy-vline
WA_/SYCLO/VIAFVC_V_STR-TPLNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-STRNO sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUTYP sy-vline
WA_/SYCLO/VIAFVC_V_STR-REFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-ERNAM sy-vline
WA_/SYCLO/VIAFVC_V_STR-ERDAT sy-vline
WA_/SYCLO/VIAFVC_V_STR-AENAM sy-vline
WA_/SYCLO/VIAFVC_V_STR-AEDAT sy-vline
WA_/SYCLO/VIAFVC_V_STR-KTEXT sy-vline
WA_/SYCLO/VIAFVC_V_STR-LTEXT sy-vline
WA_/SYCLO/VIAFVC_V_STR-WERKS sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSBER sy-vline
WA_/SYCLO/VIAFVC_V_STR-KOKRS sy-vline
WA_/SYCLO/VIAFVC_V_STR-CCKEY sy-vline
WA_/SYCLO/VIAFVC_V_STR-KOSTV sy-vline
WA_/SYCLO/VIAFVC_V_STR-SOWRK sy-vline
WA_/SYCLO/VIAFVC_V_STR-ASTKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-WAERS sy-vline
WA_/SYCLO/VIAFVC_V_STR-ASTNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-STDAT sy-vline
WA_/SYCLO/VIAFVC_V_STR-ESTNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PDAT1 sy-vline
WA_/SYCLO/VIAFVC_V_STR-PDAT2 sy-vline
WA_/SYCLO/VIAFVC_V_STR-PDAT3 sy-vline
WA_/SYCLO/VIAFVC_V_STR-IDAT1 sy-vline
WA_/SYCLO/VIAFVC_V_STR-IDAT2 sy-vline
WA_/SYCLO/VIAFVC_V_STR-IDAT3 sy-vline
WA_/SYCLO/VIAFVC_V_STR-OBJID sy-vline
WA_/SYCLO/VIAFVC_V_STR-VOGRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-LOEKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLGKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-KVEWE sy-vline
WA_/SYCLO/VIAFVC_V_STR-KAPPL sy-vline
WA_/SYCLO/VIAFVC_V_STR-KALSM sy-vline
WA_/SYCLO/VIAFVC_V_STR-ZSCHL sy-vline
WA_/SYCLO/VIAFVC_V_STR-ABKRS sy-vline
WA_/SYCLO/VIAFVC_V_STR-KSTAR sy-vline
WA_/SYCLO/VIAFVC_V_STR-SAKNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-SETNM sy-vline
WA_/SYCLO/VIAFVC_V_STR-CYCLE sy-vline
WA_/SYCLO/VIAFVC_V_STR-SDATE sy-vline
WA_/SYCLO/VIAFVC_V_STR-SEQNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-USER2 sy-vline
WA_/SYCLO/VIAFVC_V_STR-USER4 sy-vline
WA_/SYCLO/VIAFVC_V_STR-OBJNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PRCTR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PSPEL sy-vline
WA_/SYCLO/VIAFVC_V_STR-AWSLS sy-vline
WA_/SYCLO/VIAFVC_V_STR-ABGSL sy-vline
WA_/SYCLO/VIAFVC_V_STR-EB_POST sy-vline
WA_/SYCLO/VIAFVC_V_STR-TXJCD sy-vline
WA_/SYCLO/VIAFVC_V_STR-FUNC_AREA sy-vline
WA_/SYCLO/VIAFVC_V_STR-SCOPE sy-vline
WA_/SYCLO/VIAFVC_V_STR-KDAUF sy-vline
WA_/SYCLO/VIAFVC_V_STR-KDPOS sy-vline
WA_/SYCLO/VIAFVC_V_STR-IVPRO sy-vline
WA_/SYCLO/VIAFVC_V_STR-ABUKR sy-vline
WA_/SYCLO/VIAFVC_V_STR-SIZECL sy-vline
WA_/SYCLO/VIAFVC_V_STR-IZWEK sy-vline
WA_/SYCLO/VIAFVC_V_STR-UMWKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-RSORD sy-vline
WA_/SYCLO/VIAFVC_V_STR-BEMOT sy-vline
WA_/SYCLO/VIAFVC_V_STR-ADRNRA sy-vline
WA_/SYCLO/VIAFVC_V_STR-ERFZEIT sy-vline
WA_/SYCLO/VIAFVC_V_STR-AEZEIT sy-vline
WA_/SYCLO/VIAFVC_V_STR-CSTG_VRNT sy-vline
WA_/SYCLO/VIAFVC_V_STR-COSTESTNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-VERAA_USER sy-vline
WA_/SYCLO/VIAFVC_V_STR-EEW_AUFK_PS_DUMMY sy-vline
WA_/SYCLO/VIAFVC_V_STR-VNAME sy-vline
WA_/SYCLO/VIAFVC_V_STR-RECID sy-vline
WA_/SYCLO/VIAFVC_V_STR-ETYPE sy-vline
WA_/SYCLO/VIAFVC_V_STR-OTYPE sy-vline
WA_/SYCLO/VIAFVC_V_STR-JV_JIBCL sy-vline
WA_/SYCLO/VIAFVC_V_STR-JV_JIBSA sy-vline
WA_/SYCLO/VIAFVC_V_STR-JV_OCO sy-vline
WA_/SYCLO/VIAFVC_V_STR-CPD_UPDAT sy-vline
WA_/SYCLO/VIAFVC_V_STR-/CUM/INDCU sy-vline
WA_/SYCLO/VIAFVC_V_STR-/CUM/CMNUM sy-vline
WA_/SYCLO/VIAFVC_V_STR-/CUM/AUEST sy-vline
WA_/SYCLO/VIAFVC_V_STR-/CUM/DESNUM sy-vline
WA_/SYCLO/VIAFVC_V_STR-AD01PROFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-VAPLZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-WAWRK sy-vline
WA_/SYCLO/VIAFVC_V_STR-FERC_IND sy-vline
WA_/SYCLO/VIAFVC_V_STR-CLAIM_CONTROL sy-vline
WA_/SYCLO/VIAFVC_V_STR-UPDATE_NEEDED sy-vline
WA_/SYCLO/VIAFVC_V_STR-UPDATE_CONTROL sy-vline
WA_/SYCLO/VIAFVC_V_STR-GLTRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSTRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-FTRMS sy-vline
WA_/SYCLO/VIAFVC_V_STR-GLTRS sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSTRS sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSTRI sy-vline
WA_/SYCLO/VIAFVC_V_STR-GETRI sy-vline
WA_/SYCLO/VIAFVC_V_STR-GLTRI sy-vline
WA_/SYCLO/VIAFVC_V_STR-FTRMI sy-vline
WA_/SYCLO/VIAFVC_V_STR-FTRMP sy-vline
WA_/SYCLO/VIAFVC_V_STR-RSNUM sy-vline
WA_/SYCLO/VIAFVC_V_STR-GASMG sy-vline
WA_/SYCLO/VIAFVC_V_STR-GAMNG sy-vline
WA_/SYCLO/VIAFVC_V_STR-GMEIN sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLNBEZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLNTY sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLNNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLNAW sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLNAL sy-vline
WA_/SYCLO/VIAFVC_V_STR-PVERW sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLAUF sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLSVB sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLNME sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLSVN sy-vline
WA_/SYCLO/VIAFVC_V_STR-PDATV sy-vline
WA_/SYCLO/VIAFVC_V_STR-PAENR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLGRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-LODIV sy-vline
WA_/SYCLO/VIAFVC_V_STR-STLTY sy-vline
WA_/SYCLO/VIAFVC_V_STR-STLBEZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-STLST sy-vline
WA_/SYCLO/VIAFVC_V_STR-STLNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-SDATV sy-vline
WA_/SYCLO/VIAFVC_V_STR-SBMNG sy-vline
WA_/SYCLO/VIAFVC_V_STR-SBMEH sy-vline
WA_/SYCLO/VIAFVC_V_STR-SAENR sy-vline
WA_/SYCLO/VIAFVC_V_STR-STLAL sy-vline
WA_/SYCLO/VIAFVC_V_STR-STLAN sy-vline
WA_/SYCLO/VIAFVC_V_STR-SLSVN sy-vline
WA_/SYCLO/VIAFVC_V_STR-SLSBS sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUFLD sy-vline
WA_/SYCLO/VIAFVC_V_STR-DISPO sy-vline
WA_/SYCLO/VIAFVC_V_STR-FEVOR sy-vline
WA_/SYCLO/VIAFVC_V_STR-FHORI sy-vline
WA_/SYCLO/VIAFVC_V_STR-TERKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-REDKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-APRIO sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUFNT sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUFPT sy-vline
WA_/SYCLO/VIAFVC_V_STR-APLZT sy-vline
WA_/SYCLO/VIAFVC_V_STR-PROFID sy-vline
WA_/SYCLO/VIAFVC_V_STR-VORGZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-SICHZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-FREIZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-UPTER sy-vline
WA_/SYCLO/VIAFVC_V_STR-BEDID sy-vline
WA_/SYCLO/VIAFVC_V_STR-PRONR sy-vline
WA_/SYCLO/VIAFVC_V_STR-ZAEHL sy-vline
WA_/SYCLO/VIAFVC_V_STR-MZAEHL sy-vline
WA_/SYCLO/VIAFVC_V_STR-ZKRIZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-PRUEFLOS sy-vline
WA_/SYCLO/VIAFVC_V_STR-KLVARP sy-vline
WA_/SYCLO/VIAFVC_V_STR-KLVARI sy-vline
WA_/SYCLO/VIAFVC_V_STR-RGEKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLART sy-vline
WA_/SYCLO/VIAFVC_V_STR-MAUFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-LEAD_AUFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-GLUZP sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSUZP sy-vline
WA_/SYCLO/VIAFVC_V_STR-GLUZS sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSUZS sy-vline
WA_/SYCLO/VIAFVC_V_STR-GEUZI sy-vline
WA_/SYCLO/VIAFVC_V_STR-GSUZI sy-vline
WA_/SYCLO/VIAFVC_V_STR-NO_DISP sy-vline
WA_/SYCLO/VIAFVC_V_STR-STORT sy-vline
WA_/SYCLO/VIAFVC_V_STR-KOSTL sy-vline
WA_/SYCLO/VIAFVC_V_STR-ABCKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-EQFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-SWERK sy-vline
WA_/SYCLO/VIAFVC_V_STR-MSGRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-BEBER sy-vline
WA_/SYCLO/VIAFVC_V_STR-CR_OBJTY sy-vline
WA_/SYCLO/VIAFVC_V_STR-PPSID sy-vline
WA_/SYCLO/VIAFVC_V_STR-PROID sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLUN sy-vline
WA_/SYCLO/VIAFVC_V_STR-DAUFN sy-vline
WA_/SYCLO/VIAFVC_V_STR-OWNER sy-vline
WA_/SYCLO/VIAFVC_V_STR-VKORG sy-vline
WA_/SYCLO/VIAFVC_V_STR-VTWEG sy-vline
WA_/SYCLO/VIAFVC_V_STR-SPART sy-vline
WA_/SYCLO/VIAFVC_V_STR-ADRNR_ILOA sy-vline
WA_/SYCLO/VIAFVC_V_STR-VORNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-STEUS sy-vline
WA_/SYCLO/VIAFVC_V_STR-ARBID sy-vline
WA_/SYCLO/VIAFVC_V_STR-V_WERKS sy-vline
WA_/SYCLO/VIAFVC_V_STR-KTSCH sy-vline
WA_/SYCLO/VIAFVC_V_STR-LTXA1 sy-vline
WA_/SYCLO/VIAFVC_V_STR-LOANZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-LOART sy-vline
WA_/SYCLO/VIAFVC_V_STR-RSANZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-QUALF sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANZMA sy-vline
WA_/SYCLO/VIAFVC_V_STR-LOGRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-SUMNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-LIFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PREIS sy-vline
WA_/SYCLO/VIAFVC_V_STR-PEINH sy-vline
WA_/SYCLO/VIAFVC_V_STR-SAKTO sy-vline
WA_/SYCLO/VIAFVC_V_STR-V_WAERS sy-vline
WA_/SYCLO/VIAFVC_V_STR-INFNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-EKORG sy-vline
WA_/SYCLO/VIAFVC_V_STR-EKGRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-MATKL sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANZZL sy-vline
WA_/SYCLO/VIAFVC_V_STR-PRZNT sy-vline
WA_/SYCLO/VIAFVC_V_STR-INDET sy-vline
WA_/SYCLO/VIAFVC_V_STR-LARNT sy-vline
WA_/SYCLO/VIAFVC_V_STR-RUECK sy-vline
WA_/SYCLO/VIAFVC_V_STR-RMZHL sy-vline
WA_/SYCLO/VIAFVC_V_STR-V_OBJNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-BANFN sy-vline
WA_/SYCLO/VIAFVC_V_STR-BNFPO sy-vline
WA_/SYCLO/VIAFVC_V_STR-SELKZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-V_ANLZU sy-vline
WA_/SYCLO/VIAFVC_V_STR-V_ISTRU sy-vline
WA_/SYCLO/VIAFVC_V_STR-EBORT sy-vline
WA_/SYCLO/VIAFVC_V_STR-ABLAD sy-vline
WA_/SYCLO/VIAFVC_V_STR-WEMPF sy-vline
WA_/SYCLO/VIAFVC_V_STR-PERNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-TXTSP sy-vline
WA_/SYCLO/VIAFVC_V_STR-PHFLG sy-vline
WA_/SYCLO/VIAFVC_V_STR-MEINH sy-vline
WA_/SYCLO/VIAFVC_V_STR-DAUNO sy-vline
WA_/SYCLO/VIAFVC_V_STR-DAUNE sy-vline
WA_/SYCLO/VIAFVC_V_STR-DAUMI sy-vline
WA_/SYCLO/VIAFVC_V_STR-DAUME sy-vline
WA_/SYCLO/VIAFVC_V_STR-EINSA sy-vline
WA_/SYCLO/VIAFVC_V_STR-EINSE sy-vline
WA_/SYCLO/VIAFVC_V_STR-ARBEI sy-vline
WA_/SYCLO/VIAFVC_V_STR-ARBEH sy-vline
WA_/SYCLO/VIAFVC_V_STR-ISMNW sy-vline
WA_/SYCLO/VIAFVC_V_STR-FSAVD sy-vline
WA_/SYCLO/VIAFVC_V_STR-FSAVZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-FSEDD sy-vline
WA_/SYCLO/VIAFVC_V_STR-FSEDZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-SSAVD sy-vline
WA_/SYCLO/VIAFVC_V_STR-SSAVZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-SSEDD sy-vline
WA_/SYCLO/VIAFVC_V_STR-SSEDZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-ISDD sy-vline
WA_/SYCLO/VIAFVC_V_STR-ISDZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-IEDD sy-vline
WA_/SYCLO/VIAFVC_V_STR-IEDZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-PUFFR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PUFGS sy-vline
WA_/SYCLO/VIAFVC_V_STR-NTANF sy-vline
WA_/SYCLO/VIAFVC_V_STR-NTANZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-NTEND sy-vline
WA_/SYCLO/VIAFVC_V_STR-NTENZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-OFMNW sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUFKT sy-vline
WA_/SYCLO/VIAFVC_V_STR-BUKRS sy-vline
WA_/SYCLO/VIAFVC_V_STR-AUART sy-vline
WA_/SYCLO/VIAFVC_V_STR-IWERK sy-vline
WA_/SYCLO/VIAFVC_V_STR-INGPR sy-vline
WA_/SYCLO/VIAFVC_V_STR-GEWRK sy-vline
WA_/SYCLO/VIAFVC_V_STR-IPHAS sy-vline
WA_/SYCLO/VIAFVC_V_STR-ARTPR sy-vline
WA_/SYCLO/VIAFVC_V_STR-PRIOK sy-vline
WA_/SYCLO/VIAFVC_V_STR-EQUNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-BAUTL sy-vline
WA_/SYCLO/VIAFVC_V_STR-ILOAN sy-vline
WA_/SYCLO/VIAFVC_V_STR-ILOAI sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLZU sy-vline
WA_/SYCLO/VIAFVC_V_STR-APGRP sy-vline
WA_/SYCLO/VIAFVC_V_STR-PM_OBJTY sy-vline
WA_/SYCLO/VIAFVC_V_STR-KUNUM sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANING sy-vline
WA_/SYCLO/VIAFVC_V_STR-GAUZT sy-vline
WA_/SYCLO/VIAFVC_V_STR-GAUEH sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLBD sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLVD sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLBZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-ANLVZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-INSPK sy-vline
WA_/SYCLO/VIAFVC_V_STR-DATAN sy-vline
WA_/SYCLO/VIAFVC_V_STR-WARPL sy-vline
WA_/SYCLO/VIAFVC_V_STR-ABNUM sy-vline
WA_/SYCLO/VIAFVC_V_STR-WAPOS sy-vline
WA_/SYCLO/VIAFVC_V_STR-LAUFN sy-vline
WA_/SYCLO/VIAFVC_V_STR-OBKNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-REVNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-ADDAT sy-vline
WA_/SYCLO/VIAFVC_V_STR-ADUHR sy-vline
WA_/SYCLO/VIAFVC_V_STR-ILART sy-vline
WA_/SYCLO/VIAFVC_V_STR-QMNUM sy-vline
WA_/SYCLO/VIAFVC_V_STR-HISDA sy-vline
WA_/SYCLO/VIAFVC_V_STR-AKKNZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-PLKNZ sy-vline
WA_/SYCLO/VIAFVC_V_STR-SERIALNR sy-vline
WA_/SYCLO/VIAFVC_V_STR-SERMAT sy-vline
WA_/SYCLO/VIAFVC_V_STR-DEVICEID sy-vline
WA_/SYCLO/VIAFVC_V_STR-SCREENTY sy-vline
WA_/SYCLO/VIAFVC_V_STR-ADPSP sy-vline
WA_/SYCLO/VIAFVC_V_STR-RSUPG sy-vline
WA_/SYCLO/VIAFVC_V_STR-CHANGEDDATETIME sy-vline
WA_/SYCLO/VIAFVC_V_STR-MAINTORDPERSONRESPONSIBLE sy-vline
WA_/SYCLO/VIAFVC_V_STR-MAINTORDOVRLPROCPHASE sy-vline
WA_/SYCLO/VIAFVC_V_STR-MAINTORDOVRLPROCSUBPHASE sy-vline
WA_/SYCLO/VIAFVC_V_STR-DATAMODELVERSION sy-vline
WA_/SYCLO/VIAFVC_V_STR-SERVICE_DOC_TYPE sy-vline
WA_/SYCLO/VIAFVC_V_STR-SERVICE_DOC_ID sy-vline
WA_/SYCLO/VIAFVC_V_STR-SERVICE_DOC_ITEM_ID sy-vline
WA_/SYCLO/VIAFVC_V_STR-IS_BILLABLE sy-vline
WA_/SYCLO/VIAFVC_V_STR-FLDLOGSDELIVISHELDONSHORE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.