ABAP Select data from SAP table /TMF/D_ATV_IMOB into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /TMF/D_ATV_IMOB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /TMF/D_ATV_IMOB. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /TMF/D_ATV_IMOB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/TMF/D_ATV_IMOB TYPE STANDARD TABLE OF /TMF/D_ATV_IMOB, WA_/TMF/D_ATV_IMOB TYPE /TMF/D_ATV_IMOB, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </TMF/D_ATV_IMOB> TYPE /TMF/D_ATV_IMOB. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/TMF/D_ATV_IMOB. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /TMF/D_ATV_IMOB INTO TABLE IT_/TMF/D_ATV_IMOB. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /TMF/D_ATV_IMOB * INTO TABLE @DATA(IT_/TMF/D_ATV_IMOB2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/TMF/D_ATV_IMOB INDEX 1 INTO DATA(WA_/TMF/D_ATV_IMOB2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/TMF/D_ATV_IMOB ASSIGNING </TMF/D_ATV_IMOB>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</TMF/D_ATV_IMOB>-MANDT = 1.
</TMF/D_ATV_IMOB>-EMPRESA = 1.
</TMF/D_ATV_IMOB>-FILIAL = 1.
</TMF/D_ATV_IMOB>-DT_LANCTO = 1.
</TMF/D_ATV_IMOB>-NUM_LANCTO = 1.
ENDLOOP. LOOP AT IT_/TMF/D_ATV_IMOB INTO WA_/TMF/D_ATV_IMOB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/TMF/D_ATV_IMOB-IND_OPER, sy-vline,
WA_/TMF/D_ATV_IMOB-UNID_IMOB, sy-vline,
WA_/TMF/D_ATV_IMOB-IDENT_EMP, sy-vline,
WA_/TMF/D_ATV_IMOB-DESC_UNID_IMOB, sy-vline,
WA_/TMF/D_ATV_IMOB-NUM_CONT, sy-vline,
WA_/TMF/D_ATV_IMOB-CPF_CNPJ_ADQU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/TMF/D_ATV_IMOB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/TMF/D_ATV_IMOB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/TMF/D_ATV_IMOB INTO WA_/TMF/D_ATV_IMOB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/TMF/D_ATV_IMOB_STR,
MANDT TYPE STRING,
EMPRESA TYPE STRING,
FILIAL TYPE STRING,
DT_LANCTO TYPE STRING,
NUM_LANCTO TYPE STRING,
IND_OPER TYPE STRING,
UNID_IMOB TYPE STRING,
IDENT_EMP TYPE STRING,
DESC_UNID_IMOB TYPE STRING,
NUM_CONT TYPE STRING,
CPF_CNPJ_ADQU TYPE STRING,
DT_OPER TYPE STRING,
VL_TOT_VEND TYPE STRING,
VL_REC_ACUM TYPE STRING,
VL_TOT_REC TYPE STRING,
CST_PIS TYPE STRING,
VL_BC_PIS TYPE STRING,
ALIQ_PIS TYPE STRING,
VL_PIS TYPE STRING,
CST_COFINS TYPE STRING,
VL_BC_COFINS TYPE STRING,
ALIQ_COFINS TYPE STRING,
VL_COFINS TYPE STRING,
PERC_REC_RECEB TYPE STRING,
IND_NAT_EMP TYPE STRING,
INF_COMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/TMF/D_ATV_IMOB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/TMF/D_ATV_IMOB_STR-MANDT sy-vline
WA_/TMF/D_ATV_IMOB_STR-EMPRESA sy-vline
WA_/TMF/D_ATV_IMOB_STR-FILIAL sy-vline
WA_/TMF/D_ATV_IMOB_STR-DT_LANCTO sy-vline
WA_/TMF/D_ATV_IMOB_STR-NUM_LANCTO sy-vline
WA_/TMF/D_ATV_IMOB_STR-IND_OPER sy-vline
WA_/TMF/D_ATV_IMOB_STR-UNID_IMOB sy-vline
WA_/TMF/D_ATV_IMOB_STR-IDENT_EMP sy-vline
WA_/TMF/D_ATV_IMOB_STR-DESC_UNID_IMOB sy-vline
WA_/TMF/D_ATV_IMOB_STR-NUM_CONT sy-vline
WA_/TMF/D_ATV_IMOB_STR-CPF_CNPJ_ADQU sy-vline
WA_/TMF/D_ATV_IMOB_STR-DT_OPER sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_TOT_VEND sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_REC_ACUM sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_TOT_REC sy-vline
WA_/TMF/D_ATV_IMOB_STR-CST_PIS sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_BC_PIS sy-vline
WA_/TMF/D_ATV_IMOB_STR-ALIQ_PIS sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_PIS sy-vline
WA_/TMF/D_ATV_IMOB_STR-CST_COFINS sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_BC_COFINS sy-vline
WA_/TMF/D_ATV_IMOB_STR-ALIQ_COFINS sy-vline
WA_/TMF/D_ATV_IMOB_STR-VL_COFINS sy-vline
WA_/TMF/D_ATV_IMOB_STR-PERC_REC_RECEB sy-vline
WA_/TMF/D_ATV_IMOB_STR-IND_NAT_EMP sy-vline
WA_/TMF/D_ATV_IMOB_STR-INF_COMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.