ABAP Select data from SAP table /TMF/ECFREPORT_EXECUTION1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /TMF/ECFREPORT_EXECUTION1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /TMF/ECFREPORT_EXECUTION1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /TMF/ECFREPORT_EXECUTION1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/TMF/ECFREPORT_EXECUTION1 TYPE STANDARD TABLE OF /TMF/ECFREPORT_EXECUTION1,
      WA_/TMF/ECFREPORT_EXECUTION1 TYPE /TMF/ECFREPORT_EXECUTION1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </TMF/ECFREPORT_EXECUTION1> TYPE /TMF/ECFREPORT_EXECUTION1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/TMF/ECFREPORT_EXECUTION1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /TMF/ECFREPORT_EXECUTION1
  INTO TABLE IT_/TMF/ECFREPORT_EXECUTION1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /TMF/ECFREPORT_EXECUTION1
*  INTO TABLE @DATA(IT_/TMF/ECFREPORT_EXECUTION12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/TMF/ECFREPORT_EXECUTION1 INDEX 1 INTO DATA(WA_/TMF/ECFREPORT_EXECUTION12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/TMF/ECFREPORT_EXECUTION1 ASSIGNING </TMF/ECFREPORT_EXECUTION1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</TMF/ECFREPORT_EXECUTION1>-CONTROLLER = 1.
</TMF/ECFREPORT_EXECUTION1>-ECFREPORT_EXECUTION = 1.
</TMF/ECFREPORT_EXECUTION1>-CONTROLLER = 1.
</TMF/ECFREPORT_EXECUTION1>-CNPJ_ROOT = 1.
</TMF/ECFREPORT_EXECUTION1>-EMPRESA = 1.
ENDLOOP.

LOOP AT IT_/TMF/ECFREPORT_EXECUTION1 INTO WA_/TMF/ECFREPORT_EXECUTION1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/TMF/ECFREPORT_EXECUTION1-PERIODO, sy-vline,
WA_/TMF/ECFREPORT_EXECUTION1-CONTROLLER, sy-vline,
WA_/TMF/ECFREPORT_EXECUTION1-DT_DE, sy-vline,
WA_/TMF/ECFREPORT_EXECUTION1-DT_ATE, sy-vline,
WA_/TMF/ECFREPORT_EXECUTION1-REGISTROS, sy-vline,
WA_/TMF/ECFREPORT_EXECUTION1-CONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/TMF/ECFREPORT_EXECUTION1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/TMF/ECFREPORT_EXECUTION1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/TMF/ECFREPORT_EXECUTION1 INTO WA_/TMF/ECFREPORT_EXECUTION1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/TMF/ECFREPORT_EXECUTION1_STR,
CONTROLLER TYPE STRING,
ECFREPORT_EXECUTION TYPE STRING,
CONTROLLER TYPE STRING,
CNPJ_ROOT TYPE STRING,
EMPRESA TYPE STRING,
PERIODO TYPE STRING,
CONTROLLER TYPE STRING,
DT_DE TYPE STRING,
DT_ATE TYPE STRING,
REGISTROS TYPE STRING,
CONTROLLER TYPE STRING,
REG_DE TYPE STRING,
REG_ATE TYPE STRING,
CONTAS TYPE STRING,
CONTROLLER TYPE STRING,
CTA_DE TYPE STRING,
CTA_ATE TYPE STRING,
LEDGER TYPE STRING,
ESTR_BALANCO TYPE STRING,
EXEC_OFICIAL TYPE STRING,
COD_VER TYPE STRING,
DESCRICAO TYPE STRING,
USE_CTA_ALT TYPE STRING,
USE_CLUCRO TYPE STRING,
SIT_ESP TYPE STRING,
DT_SIT TYPE STRING,
TIPO_DOC TYPE STRING,END OF T_EKKO_STR. DATA: WA_/TMF/ECFREPORT_EXECUTION1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CONTROLLER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-ECFREPORT_EXECUTION sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CONTROLLER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CNPJ_ROOT sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-EMPRESA sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-PERIODO sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CONTROLLER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-DT_DE sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-DT_ATE sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-REGISTROS sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CONTROLLER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-REG_DE sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-REG_ATE sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CONTAS sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CONTROLLER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CTA_DE sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-CTA_ATE sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-LEDGER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-ESTR_BALANCO sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-EXEC_OFICIAL sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-COD_VER sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-DESCRICAO sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-USE_CTA_ALT sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-USE_CLUCRO sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-SIT_ESP sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-DT_SIT sy-vline
WA_/TMF/ECFREPORT_EXECUTION1_STR-TIPO_DOC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.