ABAP Select data from SAP table /UI2/S_CDMCONV_RESLT_LOG_FR_UI into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /UI2/S_CDMCONV_RESLT_LOG_FR_UI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /UI2/S_CDMCONV_RESLT_LOG_FR_UI. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /UI2/S_CDMCONV_RESLT_LOG_FR_UI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI TYPE STANDARD TABLE OF /UI2/S_CDMCONV_RESLT_LOG_FR_UI, WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI TYPE /UI2/S_CDMCONV_RESLT_LOG_FR_UI, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </UI2/S_CDMCONV_RESLT_LOG_FR_UI> TYPE /UI2/S_CDMCONV_RESLT_LOG_FR_UI. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/UI2/S_CDMCONV_RESLT_LOG_FR_UI. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /UI2/S_CDMCONV_RESLT_LOG_FR_UI INTO TABLE IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /UI2/S_CDMCONV_RESLT_LOG_FR_UI * INTO TABLE @DATA(IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI INDEX 1 INTO DATA(WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI ASSIGNING </UI2/S_CDMCONV_RESLT_LOG_FR_UI>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</UI2/S_CDMCONV_RESLT_LOG_FR_UI>-APP_DESCRIPTOR_ID = 1.
</UI2/S_CDMCONV_RESLT_LOG_FR_UI>-TILE_ID = 1.
</UI2/S_CDMCONV_RESLT_LOG_FR_UI>-TM_ID = 1.
</UI2/S_CDMCONV_RESLT_LOG_FR_UI>-SEMANTIC_OBJECT = 1.
</UI2/S_CDMCONV_RESLT_LOG_FR_UI>-SEMANTIC_ACTION = 1.
ENDLOOP. LOOP AT IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI INTO WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI-APP_TYPE, sy-vline,
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI-RUN_GUID, sy-vline,
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI-APPL_LOG_ID, sy-vline,
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI-CONVERTED_ON, sy-vline,
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI-CONVERTED_BY, sy-vline,
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI-TITLE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/UI2/S_CDMCONV_RESLT_LOG_FR_UI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/UI2/S_CDMCONV_RESLT_LOG_FR_UI INTO WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR,
APP_DESCRIPTOR_ID TYPE STRING,
TILE_ID TYPE STRING,
TM_ID TYPE STRING,
SEMANTIC_OBJECT TYPE STRING,
SEMANTIC_ACTION TYPE STRING,
APP_TYPE TYPE STRING,
RUN_GUID TYPE STRING,
APPL_LOG_ID TYPE STRING,
CONVERTED_ON TYPE STRING,
CONVERTED_BY TYPE STRING,
TITLE TYPE STRING,
MESSAGES TYPE STRING,
ROW_INDEX TYPE STRING,
ICON TYPE STRING,
TILE_CATALOG_ID TYPE STRING,
TM_CATALOG_ID TYPE STRING,
CONVERTED_ON_DATE TYPE STRING,
CONVERTED_ON_TIME TYPE STRING,
MESSAGE_COUNT TYPE STRING,
MESSAGE_SEVERITY TYPE STRING,
MESSAGE_NUMBERS TYPE STRING,
MESSAGE_TEXTS TYPE STRING,
MESSAGE_DISPLAY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-APP_DESCRIPTOR_ID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-TILE_ID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-TM_ID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-SEMANTIC_OBJECT sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-SEMANTIC_ACTION sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-APP_TYPE sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-RUN_GUID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-APPL_LOG_ID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-CONVERTED_ON sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-CONVERTED_BY sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-TITLE sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-MESSAGES sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-ROW_INDEX sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-ICON sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-TILE_CATALOG_ID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-TM_CATALOG_ID sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-CONVERTED_ON_DATE sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-CONVERTED_ON_TIME sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-MESSAGE_COUNT sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-MESSAGE_SEVERITY sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-MESSAGE_NUMBERS sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-MESSAGE_TEXTS sy-vline
WA_/UI2/S_CDMCONV_RESLT_LOG_FR_UI_STR-MESSAGE_DISPLAY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.