ABAP Select data from SAP table ADPIC_S_ATP_SEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ADPIC_S_ATP_SEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ADPIC_S_ATP_SEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ADPIC_S_ATP_SEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ADPIC_S_ATP_SEL TYPE STANDARD TABLE OF ADPIC_S_ATP_SEL,
      WA_ADPIC_S_ATP_SEL TYPE ADPIC_S_ATP_SEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ADPIC_S_ATP_SEL> TYPE ADPIC_S_ATP_SEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ADPIC_S_ATP_SEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ADPIC_S_ATP_SEL
  INTO TABLE IT_ADPIC_S_ATP_SEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ADPIC_S_ATP_SEL
*  INTO TABLE @DATA(IT_ADPIC_S_ATP_SEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ADPIC_S_ATP_SEL INDEX 1 INTO DATA(WA_ADPIC_S_ATP_SEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ADPIC_S_ATP_SEL ASSIGNING <ADPIC_S_ATP_SEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ADPIC_S_ATP_SEL>-EXCHANGE = 1.
<ADPIC_S_ATP_SEL>-DELNR = 1.
<ADPIC_S_ATP_SEL>-DELPS = 1.
<ADPIC_S_ATP_SEL>-MATNR = 1.
<ADPIC_S_ATP_SEL>-WERKS = 1.
ENDLOOP.

LOOP AT IT_ADPIC_S_ATP_SEL INTO WA_ADPIC_S_ATP_SEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ADPIC_S_ATP_SEL-LGORT, sy-vline,
WA_ADPIC_S_ATP_SEL-CHARG, sy-vline,
WA_ADPIC_S_ATP_SEL-SERNR, sy-vline,
WA_ADPIC_S_ATP_SEL-BERID, sy-vline,
WA_ADPIC_S_ATP_SEL-BDMNG, sy-vline,
WA_ADPIC_S_ATP_SEL-ATPMG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ADPIC_S_ATP_SEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ADPIC_S_ATP_SEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ADPIC_S_ATP_SEL INTO WA_ADPIC_S_ATP_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ADPIC_S_ATP_SEL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ADPIC_S_ATP_SEL-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ADPIC_S_ATP_SEL-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ADPIC_S_ATP_SEL-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ADPIC_S_ATP_SEL_STR,
EXCHANGE TYPE STRING,
DELNR TYPE STRING,
DELPS TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
SERNR TYPE STRING,
BERID TYPE STRING,
BDMNG TYPE STRING,
ATPMG TYPE STRING,
MEINS TYPE STRING,
SOBKZ TYPE STRING,
MRPGR TYPE STRING,
IC_RBA TYPE STRING,
POSGUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_ADPIC_S_ATP_SEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ADPIC_S_ATP_SEL_STR-EXCHANGE sy-vline
WA_ADPIC_S_ATP_SEL_STR-DELNR sy-vline
WA_ADPIC_S_ATP_SEL_STR-DELPS sy-vline
WA_ADPIC_S_ATP_SEL_STR-MATNR sy-vline
WA_ADPIC_S_ATP_SEL_STR-WERKS sy-vline
WA_ADPIC_S_ATP_SEL_STR-LGORT sy-vline
WA_ADPIC_S_ATP_SEL_STR-CHARG sy-vline
WA_ADPIC_S_ATP_SEL_STR-SERNR sy-vline
WA_ADPIC_S_ATP_SEL_STR-BERID sy-vline
WA_ADPIC_S_ATP_SEL_STR-BDMNG sy-vline
WA_ADPIC_S_ATP_SEL_STR-ATPMG sy-vline
WA_ADPIC_S_ATP_SEL_STR-MEINS sy-vline
WA_ADPIC_S_ATP_SEL_STR-SOBKZ sy-vline
WA_ADPIC_S_ATP_SEL_STR-MRPGR sy-vline
WA_ADPIC_S_ATP_SEL_STR-IC_RBA sy-vline
WA_ADPIC_S_ATP_SEL_STR-POSGUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.