ABAP Select data from SAP table ADSPC_PDR_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ADSPC_PDR_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ADSPC_PDR_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ADSPC_PDR_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ADSPC_PDR_C TYPE STANDARD TABLE OF ADSPC_PDR_C,
      WA_ADSPC_PDR_C TYPE ADSPC_PDR_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ADSPC_PDR_C> TYPE ADSPC_PDR_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ADSPC_PDR_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ADSPC_PDR_C
  INTO TABLE IT_ADSPC_PDR_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ADSPC_PDR_C
*  INTO TABLE @DATA(IT_ADSPC_PDR_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ADSPC_PDR_C INDEX 1 INTO DATA(WA_ADSPC_PDR_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ADSPC_PDR_C ASSIGNING <ADSPC_PDR_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ADSPC_PDR_C>-CLIENT = 1.
<ADSPC_PDR_C>-SQNBR = 1.
<ADSPC_PDR_C>-PNR = 1.
<ADSPC_PDR_C>-MFR = 1.
<ADSPC_PDR_C>-EIP = 1.
ENDLOOP.

LOOP AT IT_ADSPC_PDR_C INTO WA_ADSPC_PDR_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ADSPC_PDR_C-EIM, sy-vline,
WA_ADSPC_PDR_C-SPC, sy-vline,
WA_ADSPC_PDR_C-URR, sy-vline,
WA_ADSPC_PDR_C-URRTCC, sy-vline,
WA_ADSPC_PDR_C-TCBSV, sy-vline,
WA_ADSPC_PDR_C-TCBSVTCC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ADSPC_PDR_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ADSPC_PDR_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ADSPC_PDR_C INTO WA_ADSPC_PDR_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ADSPC_PDR_C_STR,
CLIENT TYPE STRING,
SQNBR TYPE STRING,
PNR TYPE STRING,
MFR TYPE STRING,
EIP TYPE STRING,
EIM TYPE STRING,
SPC TYPE STRING,
URR TYPE STRING,
URRTCC TYPE STRING,
TCBSV TYPE STRING,
TCBSVTCC TYPE STRING,
TCBO TYPE STRING,
TCBOTCC TYPE STRING,
SCR TYPE STRING,
REC TYPE STRING,
TQA TYPE STRING,
MPC TYPE STRING,
SLC TYPE STRING,
SLC_UPPER TYPE STRING,
MST TYPE STRING,
OPN TYPE STRING,
HAZ TYPE STRING,
PIC TYPE STRING,
ESD TYPE STRING,
RMC TYPE STRING,
ICC TYPE STRING,
OBJ TYPE STRING,
DELFLG TYPE STRING,
CHG_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ADSPC_PDR_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ADSPC_PDR_C_STR-CLIENT sy-vline
WA_ADSPC_PDR_C_STR-SQNBR sy-vline
WA_ADSPC_PDR_C_STR-PNR sy-vline
WA_ADSPC_PDR_C_STR-MFR sy-vline
WA_ADSPC_PDR_C_STR-EIP sy-vline
WA_ADSPC_PDR_C_STR-EIM sy-vline
WA_ADSPC_PDR_C_STR-SPC sy-vline
WA_ADSPC_PDR_C_STR-URR sy-vline
WA_ADSPC_PDR_C_STR-URRTCC sy-vline
WA_ADSPC_PDR_C_STR-TCBSV sy-vline
WA_ADSPC_PDR_C_STR-TCBSVTCC sy-vline
WA_ADSPC_PDR_C_STR-TCBO sy-vline
WA_ADSPC_PDR_C_STR-TCBOTCC sy-vline
WA_ADSPC_PDR_C_STR-SCR sy-vline
WA_ADSPC_PDR_C_STR-REC sy-vline
WA_ADSPC_PDR_C_STR-TQA sy-vline
WA_ADSPC_PDR_C_STR-MPC sy-vline
WA_ADSPC_PDR_C_STR-SLC sy-vline
WA_ADSPC_PDR_C_STR-SLC_UPPER sy-vline
WA_ADSPC_PDR_C_STR-MST sy-vline
WA_ADSPC_PDR_C_STR-OPN sy-vline
WA_ADSPC_PDR_C_STR-HAZ sy-vline
WA_ADSPC_PDR_C_STR-PIC sy-vline
WA_ADSPC_PDR_C_STR-ESD sy-vline
WA_ADSPC_PDR_C_STR-RMC sy-vline
WA_ADSPC_PDR_C_STR-ICC sy-vline
WA_ADSPC_PDR_C_STR-OBJ sy-vline
WA_ADSPC_PDR_C_STR-DELFLG sy-vline
WA_ADSPC_PDR_C_STR-CHG_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.