ABAP Select data from SAP table ADT_ST05_TRACE_STATE_INST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ADT_ST05_TRACE_STATE_INST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ADT_ST05_TRACE_STATE_INST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ADT_ST05_TRACE_STATE_INST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ADT_ST05_TRACE_STATE_INST TYPE STANDARD TABLE OF ADT_ST05_TRACE_STATE_INST, WA_ADT_ST05_TRACE_STATE_INST TYPE ADT_ST05_TRACE_STATE_INST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ADT_ST05_TRACE_STATE_INST> TYPE ADT_ST05_TRACE_STATE_INST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ADT_ST05_TRACE_STATE_INST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ADT_ST05_TRACE_STATE_INST INTO TABLE IT_ADT_ST05_TRACE_STATE_INST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ADT_ST05_TRACE_STATE_INST * INTO TABLE @DATA(IT_ADT_ST05_TRACE_STATE_INST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ADT_ST05_TRACE_STATE_INST INDEX 1 INTO DATA(WA_ADT_ST05_TRACE_STATE_INST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ADT_ST05_TRACE_STATE_INST ASSIGNING <ADT_ST05_TRACE_STATE_INST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ADT_ST05_TRACE_STATE_INST>-INSTANCE = 1.
<ADT_ST05_TRACE_STATE_INST>-HOST = 1.
<ADT_ST05_TRACE_STATE_INST>-IS_LOCAL = 1.
<ADT_ST05_TRACE_STATE_INST>-IS_SELECTED = 1.
<ADT_ST05_TRACE_STATE_INST>-MODIFICATION_USER = 1.
ENDLOOP. LOOP AT IT_ADT_ST05_TRACE_STATE_INST INTO WA_ADT_ST05_TRACE_STATE_INST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ADT_ST05_TRACE_STATE_INST-MODIFICATION_DATE_TIME, sy-vline,
WA_ADT_ST05_TRACE_STATE_INST-TRACE_TYPES, sy-vline,
WA_ADT_ST05_TRACE_STATE_INST-SQL_ON, sy-vline,
WA_ADT_ST05_TRACE_STATE_INST-BUF_ON, sy-vline,
WA_ADT_ST05_TRACE_STATE_INST-ENQ_ON, sy-vline,
WA_ADT_ST05_TRACE_STATE_INST-RFC_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ADT_ST05_TRACE_STATE_INST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ADT_ST05_TRACE_STATE_INST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ADT_ST05_TRACE_STATE_INST INTO WA_ADT_ST05_TRACE_STATE_INST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ADT_ST05_TRACE_STATE_INST_STR,
INSTANCE TYPE STRING,
HOST TYPE STRING,
IS_LOCAL TYPE STRING,
IS_SELECTED TYPE STRING,
MODIFICATION_USER TYPE STRING,
MODIFICATION_DATE_TIME TYPE STRING,
TRACE_TYPES TYPE STRING,
SQL_ON TYPE STRING,
BUF_ON TYPE STRING,
ENQ_ON TYPE STRING,
RFC_ON TYPE STRING,
HTTP_ON TYPE STRING,
APC_ON TYPE STRING,
AMC_ON TYPE STRING,
AUTH_ON TYPE STRING,
TRACE_PROPERTIES TYPE STRING,
INCLUDE_MISSING_TABLE_NAME_ON TYPE STRING,
AUTH_ERRORS_ONLY TYPE STRING,
STACK_TRACE_ON TYPE STRING,
INCLUDED_TABLES TYPE STRING,
EXCLUDED_TABLES TYPE STRING,
TRACE_FILTER TYPE STRING,
TRACE_USER TYPE STRING,
TRANSACTION_CODE TYPE STRING,
PROGRAM TYPE STRING,
RFC_FUNCTION TYPE STRING,
URL TYPE STRING,
WP_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_ADT_ST05_TRACE_STATE_INST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-INSTANCE sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-HOST sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-IS_LOCAL sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-IS_SELECTED sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-MODIFICATION_USER sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-MODIFICATION_DATE_TIME sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-TRACE_TYPES sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-SQL_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-BUF_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-ENQ_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-RFC_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-HTTP_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-APC_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-AMC_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-AUTH_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-TRACE_PROPERTIES sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-INCLUDE_MISSING_TABLE_NAME_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-AUTH_ERRORS_ONLY sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-STACK_TRACE_ON sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-INCLUDED_TABLES sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-EXCLUDED_TABLES sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-TRACE_FILTER sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-TRACE_USER sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-TRANSACTION_CODE sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-PROGRAM sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-RFC_FUNCTION sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-URL sy-vline
WA_ADT_ST05_TRACE_STATE_INST_STR-WP_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.