ABAP Select data from SAP table AEOI_API01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AEOI_API01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AEOI_API01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AEOI_API01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AEOI_API01 TYPE STANDARD TABLE OF AEOI_API01,
      WA_AEOI_API01 TYPE AEOI_API01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AEOI_API01> TYPE AEOI_API01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AEOI_API01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AEOI_API01
  INTO TABLE IT_AEOI_API01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AEOI_API01
*  INTO TABLE @DATA(IT_AEOI_API012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AEOI_API01 INDEX 1 INTO DATA(WA_AEOI_API012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AEOI_API01 ASSIGNING <AEOI_API01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AEOI_API01>-ALT_DATE = 1.
<AEOI_API01>-CHG_OBJTYP = 1.
<AEOI_API01>-BOM_CAT = 1.
<AEOI_API01>-BOM_STD_OBJECT = 1.
<AEOI_API01>-BOM_USAGE = 1.
ENDLOOP.

LOOP AT IT_AEOI_API01 INTO WA_AEOI_API01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AEOI_API01-CHGTYPEOBJ, sy-vline,
WA_AEOI_API01-DESCR_OBJ, sy-vline,
WA_AEOI_API01-DOC_TYPE, sy-vline,
WA_AEOI_API01-DOC_NUMBER, sy-vline,
WA_AEOI_API01-DOC_VERS, sy-vline,
WA_AEOI_API01-DOC_PART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AEOI_API01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AEOI_API01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AEOI_API01 INTO WA_AEOI_API01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOC_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AEOI_API01-DOC_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI_API01-DOC_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AEOI_API01-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI_API01-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CCTPL, internal->external for field FUNC_LOC CALL FUNCTION 'CONVERSION_EXIT_CCTPL_OUTPUT' EXPORTING input = WA_AEOI_API01-FUNC_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI_API01-FUNC_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CCMAT, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_CCMAT_OUTPUT' EXPORTING input = WA_AEOI_API01-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI_API01-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SD_ORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AEOI_API01-SD_ORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI_API01-SD_ORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TLIST_GRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AEOI_API01-TLIST_GRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI_API01-TLIST_GRP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AEOI_API01_STR,
ALT_DATE TYPE STRING,
CHG_OBJTYP TYPE STRING,
BOM_CAT TYPE STRING,
BOM_STD_OBJECT TYPE STRING,
BOM_USAGE TYPE STRING,
CHGTYPEOBJ TYPE STRING,
DESCR_OBJ TYPE STRING,
DOC_TYPE TYPE STRING,
DOC_NUMBER TYPE STRING,
DOC_VERS TYPE STRING,
DOC_PART TYPE STRING,
EQUIPMENT TYPE STRING,
FUNC_LOC TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
PSP_ELEMENT TYPE STRING,
PVS_GUID TYPE STRING,
PVS_TYPE TYPE STRING,
PVS_NODE TYPE STRING,
PVS_CLASS_NUMBER TYPE STRING,
PVS_CLASS_TYPE TYPE STRING,
PVS_VARIANT TYPE STRING,
SD_ORDER TYPE STRING,
SD_ORDER_I TYPE STRING,
TEXTKEY TYPE STRING,
TLIST_TYPE TYPE STRING,
TLIST_GRP TYPE STRING,
OBJ_CHGLOCK TYPE STRING,
STATUS_PROF_OBJ TYPE STRING,
FL_DELETE TYPE STRING,
AEOI_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_AEOI_API01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AEOI_API01_STR-ALT_DATE sy-vline
WA_AEOI_API01_STR-CHG_OBJTYP sy-vline
WA_AEOI_API01_STR-BOM_CAT sy-vline
WA_AEOI_API01_STR-BOM_STD_OBJECT sy-vline
WA_AEOI_API01_STR-BOM_USAGE sy-vline
WA_AEOI_API01_STR-CHGTYPEOBJ sy-vline
WA_AEOI_API01_STR-DESCR_OBJ sy-vline
WA_AEOI_API01_STR-DOC_TYPE sy-vline
WA_AEOI_API01_STR-DOC_NUMBER sy-vline
WA_AEOI_API01_STR-DOC_VERS sy-vline
WA_AEOI_API01_STR-DOC_PART sy-vline
WA_AEOI_API01_STR-EQUIPMENT sy-vline
WA_AEOI_API01_STR-FUNC_LOC sy-vline
WA_AEOI_API01_STR-MATERIAL sy-vline
WA_AEOI_API01_STR-PLANT sy-vline
WA_AEOI_API01_STR-PSP_ELEMENT sy-vline
WA_AEOI_API01_STR-PVS_GUID sy-vline
WA_AEOI_API01_STR-PVS_TYPE sy-vline
WA_AEOI_API01_STR-PVS_NODE sy-vline
WA_AEOI_API01_STR-PVS_CLASS_NUMBER sy-vline
WA_AEOI_API01_STR-PVS_CLASS_TYPE sy-vline
WA_AEOI_API01_STR-PVS_VARIANT sy-vline
WA_AEOI_API01_STR-SD_ORDER sy-vline
WA_AEOI_API01_STR-SD_ORDER_I sy-vline
WA_AEOI_API01_STR-TEXTKEY sy-vline
WA_AEOI_API01_STR-TLIST_TYPE sy-vline
WA_AEOI_API01_STR-TLIST_GRP sy-vline
WA_AEOI_API01_STR-OBJ_CHGLOCK sy-vline
WA_AEOI_API01_STR-STATUS_PROF_OBJ sy-vline
WA_AEOI_API01_STR-FL_DELETE sy-vline
WA_AEOI_API01_STR-AEOI_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.