ABAP Select data from SAP table ALM_ME_ML_ORDER_TIME_CONF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ALM_ME_ML_ORDER_TIME_CONF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ALM_ME_ML_ORDER_TIME_CONF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ALM_ME_ML_ORDER_TIME_CONF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ALM_ME_ML_ORDER_TIME_CONF TYPE STANDARD TABLE OF ALM_ME_ML_ORDER_TIME_CONF, WA_ALM_ME_ML_ORDER_TIME_CONF TYPE ALM_ME_ML_ORDER_TIME_CONF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ALM_ME_ML_ORDER_TIME_CONF> TYPE ALM_ME_ML_ORDER_TIME_CONF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ALM_ME_ML_ORDER_TIME_CONF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ALM_ME_ML_ORDER_TIME_CONF INTO TABLE IT_ALM_ME_ML_ORDER_TIME_CONF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ALM_ME_ML_ORDER_TIME_CONF * INTO TABLE @DATA(IT_ALM_ME_ML_ORDER_TIME_CONF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ALM_ME_ML_ORDER_TIME_CONF INDEX 1 INTO DATA(WA_ALM_ME_ML_ORDER_TIME_CONF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ALM_ME_ML_ORDER_TIME_CONF ASSIGNING <ALM_ME_ML_ORDER_TIME_CONF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ALM_ME_ML_ORDER_TIME_CONF>-ORDER_NO = 1.
<ALM_ME_ML_ORDER_TIME_CONF>-ACTIVITY = 1.
<ALM_ME_ML_ORDER_TIME_CONF>-CONF_NO = 1.
<ALM_ME_ML_ORDER_TIME_CONF>-CONF_CNT = 1.
<ALM_ME_ML_ORDER_TIME_CONF>-SPRAS = 1.
ENDLOOP. LOOP AT IT_ALM_ME_ML_ORDER_TIME_CONF INTO WA_ALM_ME_ML_ORDER_TIME_CONF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK, sy-vline,
WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK_ISO, sy-vline,
WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_DUR, sy-vline,
WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_WRK, sy-vline,
WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_WRK_ISO, sy-vline,
WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK_DIA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ALM_ME_ML_ORDER_TIME_CONF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ALM_ME_ML_ORDER_TIME_CONF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ALM_ME_ML_ORDER_TIME_CONF INTO WA_ALM_ME_ML_ORDER_TIME_CONF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field ORDER_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-ORDER_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-ORDER_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field ACTIVITY CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-ACTIVITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-ACTIVITY.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-SPRAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UN_WORK CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UN_REM_DUR CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_DUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_DUR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UN_REM_WRK CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_WRK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-UN_REM_WRK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UN_WORK_DIA CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK_DIA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ALM_ME_ML_ORDER_TIME_CONF-UN_WORK_DIA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ALM_ME_ML_ORDER_TIME_CONF_STR,
ORDER_NO TYPE STRING,
ACTIVITY TYPE STRING,
CONF_NO TYPE STRING,
CONF_CNT TYPE STRING,
SPRAS TYPE STRING,
UN_WORK TYPE STRING,
UN_WORK_ISO TYPE STRING,
UN_REM_DUR TYPE STRING,
UN_REM_WRK TYPE STRING,
UN_REM_WRK_ISO TYPE STRING,
UN_WORK_DIA TYPE STRING,
UN_WORK_DIA_ISO TYPE STRING,END OF T_EKKO_STR. DATA: WA_ALM_ME_ML_ORDER_TIME_CONF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-ORDER_NO sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-ACTIVITY sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-CONF_NO sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-CONF_CNT sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-SPRAS sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-UN_WORK sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-UN_WORK_ISO sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-UN_REM_DUR sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-UN_REM_WRK sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-UN_REM_WRK_ISO sy-vline
WA_ALM_ME_ML_ORDER_TIME_CONF_STR-UN_WORK_DIA sy-vline