ABAP Select data from SAP table ALMTCUST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ALMTCUST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ALMTCUST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ALMTCUST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ALMTCUST TYPE STANDARD TABLE OF ALMTCUST, WA_ALMTCUST TYPE ALMTCUST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ALMTCUST> TYPE ALMTCUST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ALMTCUST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ALMTCUST INTO TABLE IT_ALMTCUST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ALMTCUST * INTO TABLE @DATA(IT_ALMTCUST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ALMTCUST INDEX 1 INTO DATA(WA_ALMTCUST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ALMTCUST ASSIGNING <ALMTCUST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ALMTCUST>-CUSTSTATUS = 1.
<ALMTCUST>-USECLASS = 1.
<ALMTCUST>-SEVERITY = 1.
<ALMTCUST>-STATISTREC = 1.
<ALMTCUST>-VISUSERLEV = 1.
ENDLOOP. LOOP AT IT_ALMTCUST INTO WA_ALMTCUST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ALMTCUST-KEEPALTYPE, sy-vline,
WA_ALMTCUST-KEEPALMAX, sy-vline,
WA_ALMTCUST-SECTRGTOOL, sy-vline,
WA_ALMTCUST-SECINACTIV, sy-vline,
WA_ALMTCUST-WARMUPTIME, sy-vline,
WA_ALMTCUST-DTEXTCLASS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ALMTCUST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ALMTCUST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ALMTCUST INTO WA_ALMTCUST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ALMTCUST_STR,
CUSTSTATUS TYPE STRING,
USECLASS TYPE STRING,
SEVERITY TYPE STRING,
STATISTREC TYPE STRING,
VISUSERLEV TYPE STRING,
KEEPALTYPE TYPE STRING,
KEEPALMAX TYPE STRING,
SECTRGTOOL TYPE STRING,
SECINACTIV TYPE STRING,
WARMUPTIME TYPE STRING,
DTEXTCLASS TYPE STRING,
DTEXTID TYPE STRING,
CUSGRPNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_ALMTCUST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ALMTCUST_STR-CUSTSTATUS sy-vline
WA_ALMTCUST_STR-USECLASS sy-vline
WA_ALMTCUST_STR-SEVERITY sy-vline
WA_ALMTCUST_STR-STATISTREC sy-vline
WA_ALMTCUST_STR-VISUSERLEV sy-vline
WA_ALMTCUST_STR-KEEPALTYPE sy-vline
WA_ALMTCUST_STR-KEEPALMAX sy-vline
WA_ALMTCUST_STR-SECTRGTOOL sy-vline
WA_ALMTCUST_STR-SECINACTIV sy-vline
WA_ALMTCUST_STR-WARMUPTIME sy-vline
WA_ALMTCUST_STR-DTEXTCLASS sy-vline
WA_ALMTCUST_STR-DTEXTID sy-vline
WA_ALMTCUST_STR-CUSGRPNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.