ABAP Select data from SAP table ARUN_S_SUBCONPO_LOG into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ARUN_S_SUBCONPO_LOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ARUN_S_SUBCONPO_LOG. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ARUN_S_SUBCONPO_LOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ARUN_S_SUBCONPO_LOG TYPE STANDARD TABLE OF ARUN_S_SUBCONPO_LOG, WA_ARUN_S_SUBCONPO_LOG TYPE ARUN_S_SUBCONPO_LOG, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ARUN_S_SUBCONPO_LOG> TYPE ARUN_S_SUBCONPO_LOG. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ARUN_S_SUBCONPO_LOG. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ARUN_S_SUBCONPO_LOG INTO TABLE IT_ARUN_S_SUBCONPO_LOG. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ARUN_S_SUBCONPO_LOG * INTO TABLE @DATA(IT_ARUN_S_SUBCONPO_LOG2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ARUN_S_SUBCONPO_LOG INDEX 1 INTO DATA(WA_ARUN_S_SUBCONPO_LOG2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ARUN_S_SUBCONPO_LOG ASSIGNING <ARUN_S_SUBCONPO_LOG>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ARUN_S_SUBCONPO_LOG>-STATUS = 1.
<ARUN_S_SUBCONPO_LOG>-COMPONENT = 1.
<ARUN_S_SUBCONPO_LOG>-PO_NUM = 1.
<ARUN_S_SUBCONPO_LOG>-PO_ITEM = 1.
<ARUN_S_SUBCONPO_LOG>-RESV_NUM = 1.
ENDLOOP. LOOP AT IT_ARUN_S_SUBCONPO_LOG INTO WA_ARUN_S_SUBCONPO_LOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ARUN_S_SUBCONPO_LOG-RESV_ITM, sy-vline,
WA_ARUN_S_SUBCONPO_LOG-REQ_QTY, sy-vline,
WA_ARUN_S_SUBCONPO_LOG-OPEN_QTY_FOR_ASSIGNMENT, sy-vline,
WA_ARUN_S_SUBCONPO_LOG-ASSIGNED_QTY, sy-vline,
WA_ARUN_S_SUBCONPO_LOG-DELIV_QTY, sy-vline,
WA_ARUN_S_SUBCONPO_LOG-FULFILLMENT_PER_COMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ARUN_S_SUBCONPO_LOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ARUN_S_SUBCONPO_LOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ARUN_S_SUBCONPO_LOG INTO WA_ARUN_S_SUBCONPO_LOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field COMPONENT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ARUN_S_SUBCONPO_LOG-COMPONENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARUN_S_SUBCONPO_LOG-COMPONENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PO_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARUN_S_SUBCONPO_LOG-PO_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARUN_S_SUBCONPO_LOG-PO_NUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BASE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARUN_S_SUBCONPO_LOG-BASE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARUN_S_SUBCONPO_LOG-BASE_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ARUN_S_SUBCONPO_LOG_STR,
STATUS TYPE STRING,
COMPONENT TYPE STRING,
PO_NUM TYPE STRING,
PO_ITEM TYPE STRING,
RESV_NUM TYPE STRING,
RESV_ITM TYPE STRING,
REQ_QTY TYPE STRING,
OPEN_QTY_FOR_ASSIGNMENT TYPE STRING,
ASSIGNED_QTY TYPE STRING,
DELIV_QTY TYPE STRING,
FULFILLMENT_PER_COMP TYPE STRING,
FULFILLMENT_PER_ITEM TYPE STRING,
FULFILLMENT_PER_HEADER TYPE STRING,
BASE_UOM TYPE STRING,
MESSAGE TYPE STRING,
MSGTY TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_ARUN_S_SUBCONPO_LOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-STATUS sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-COMPONENT sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-PO_NUM sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-PO_ITEM sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-RESV_NUM sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-RESV_ITM sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-REQ_QTY sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-OPEN_QTY_FOR_ASSIGNMENT sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-ASSIGNED_QTY sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-DELIV_QTY sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-FULFILLMENT_PER_COMP sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-FULFILLMENT_PER_ITEM sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-FULFILLMENT_PER_HEADER sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-BASE_UOM sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MESSAGE sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGTY sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGID sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGNO sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGV1 sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGV2 sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGV3 sy-vline
WA_ARUN_S_SUBCONPO_LOG_STR-MSGV4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.