ABAP Select data from SAP table AUSPC_V3 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP AUSPC_V3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AUSPC_V3. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the AUSPC_V3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_AUSPC_V3 TYPE STANDARD TABLE OF AUSPC_V3, WA_AUSPC_V3 TYPE AUSPC_V3, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <AUSPC_V3> TYPE AUSPC_V3. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_AUSPC_V3. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM AUSPC_V3 INTO TABLE IT_AUSPC_V3. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM AUSPC_V3 * INTO TABLE @DATA(IT_AUSPC_V32). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_AUSPC_V3 INDEX 1 INTO DATA(WA_AUSPC_V32). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_AUSPC_V3 ASSIGNING <AUSPC_V3>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<AUSPC_V3>-MANDT = 1.
<AUSPC_V3>-OBJEK = 1.
<AUSPC_V3>-ATINN = 1.
<AUSPC_V3>-ATZHL = 1.
<AUSPC_V3>-MAFID = 1.
ENDLOOP. LOOP AT IT_AUSPC_V3 INTO WA_AUSPC_V3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_AUSPC_V3-KLART, sy-vline,
WA_AUSPC_V3-ADZHL, sy-vline,
WA_AUSPC_V3-ATWRT, sy-vline,
WA_AUSPC_V3-ATCOD, sy-vline,
WA_AUSPC_V3-ATTLV, sy-vline,
WA_AUSPC_V3-ATTLB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AUSPC_V3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AUSPC_V3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AUSPC_V3 INTO WA_AUSPC_V3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ATINN, internal->external for field ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_AUSPC_V3-ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSPC_V3-ATINN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ATINN, internal->external for field ATIMB CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_AUSPC_V3-ATIMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSPC_V3-ATIMB.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AUSPC_V3_STR,
MANDT TYPE STRING,
OBJEK TYPE STRING,
ATINN TYPE STRING,
ATZHL TYPE STRING,
MAFID TYPE STRING,
KLART TYPE STRING,
ADZHL TYPE STRING,
ATWRT TYPE STRING,
ATCOD TYPE STRING,
ATTLV TYPE STRING,
ATTLB TYPE STRING,
ATPRZ TYPE STRING,
ATAUT TYPE STRING,
DATUV TYPE STRING,
LKENZ TYPE STRING,
ATIMB TYPE STRING,
ATZIS TYPE STRING,
ATSRT TYPE STRING,
ATVGLART TYPE STRING,
DATUB TYPE STRING,END OF T_EKKO_STR. DATA: WA_AUSPC_V3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AUSPC_V3_STR-MANDT sy-vline
WA_AUSPC_V3_STR-OBJEK sy-vline
WA_AUSPC_V3_STR-ATINN sy-vline
WA_AUSPC_V3_STR-ATZHL sy-vline
WA_AUSPC_V3_STR-MAFID sy-vline
WA_AUSPC_V3_STR-KLART sy-vline
WA_AUSPC_V3_STR-ADZHL sy-vline
WA_AUSPC_V3_STR-ATWRT sy-vline
WA_AUSPC_V3_STR-ATCOD sy-vline
WA_AUSPC_V3_STR-ATTLV sy-vline
WA_AUSPC_V3_STR-ATTLB sy-vline
WA_AUSPC_V3_STR-ATPRZ sy-vline
WA_AUSPC_V3_STR-ATAUT sy-vline
WA_AUSPC_V3_STR-DATUV sy-vline
WA_AUSPC_V3_STR-LKENZ sy-vline
WA_AUSPC_V3_STR-ATIMB sy-vline
WA_AUSPC_V3_STR-ATZIS sy-vline
WA_AUSPC_V3_STR-ATSRT sy-vline
WA_AUSPC_V3_STR-ATVGLART sy-vline
WA_AUSPC_V3_STR-DATUB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.