ABAP Select data from SAP table AVIAK26 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP AVIAK26 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AVIAK26. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the AVIAK26 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_AVIAK26 TYPE STANDARD TABLE OF AVIAK26, WA_AVIAK26 TYPE AVIAK26, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <AVIAK26> TYPE AVIAK26. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_AVIAK26. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM AVIAK26 INTO TABLE IT_AVIAK26. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM AVIAK26 * INTO TABLE @DATA(IT_AVIAK262). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_AVIAK26 INDEX 1 INTO DATA(WA_AVIAK262). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_AVIAK26 ASSIGNING <AVIAK26>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<AVIAK26>-MANDT = 1.
<AVIAK26>-BUKRS = 1.
<AVIAK26>-SWENR = 1.
<AVIAK26>-SNKSL = 1.
<AVIAK26>-SEMPSL = 1.
ENDLOOP. LOOP AT IT_AVIAK26 INTO WA_AVIAK26. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_AVIAK26-DGUELEMP, sy-vline,
WA_AVIAK26-TBUKRS, sy-vline,
WA_AVIAK26-TSWENR, sy-vline,
WA_AVIAK26-TSNKSL, sy-vline,
WA_AVIAK26-TSEMPSL, sy-vline,
WA_AVIAK26-SABRG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AVIAK26 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AVIAK26 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AVIAK26 INTO WA_AVIAK26. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_AVIAK26-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-SWENR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SNKSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AVIAK26-SNKSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-SNKSL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SEMPSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AVIAK26-SEMPSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-SEMPSL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit SWENR, internal->external for field TSWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_AVIAK26-TSWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-TSWENR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TSNKSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AVIAK26-TSNKSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-TSNKSL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TSEMPSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AVIAK26-TSEMPSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-TSEMPSL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field XEINHEIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_AVIAK26-XEINHEIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-XEINHEIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MEAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AVIAK26-MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AVIAK26-MEAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AVIAK26_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SNKSL TYPE STRING,
SEMPSL TYPE STRING,
DGUELEMP TYPE STRING,
TBUKRS TYPE STRING,
TSWENR TYPE STRING,
TSNKSL TYPE STRING,
TSEMPSL TYPE STRING,
SABRG TYPE STRING,
EQUINUM TYPE STRING,
XEINHEIT TYPE STRING,
PROZ TYPE STRING,
JDISTRIBUTE TYPE STRING,
VOLWATER TYPE STRING,
TEMPWATER TYPE STRING,
HEATVALUE TYPE STRING,
KBRART TYPE STRING,
GCONSUMP TYPE STRING,
QHEATAMOUNT TYPE STRING,
BCONSUMP TYPE STRING,
WHEATAMOUNT TYPE STRING,
WWPROZ TYPE STRING,
HKVOTYP TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
OBJNR TYPE STRING,
MEAS TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_AVIAK26_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AVIAK26_STR-MANDT sy-vline
WA_AVIAK26_STR-BUKRS sy-vline
WA_AVIAK26_STR-SWENR sy-vline
WA_AVIAK26_STR-SNKSL sy-vline
WA_AVIAK26_STR-SEMPSL sy-vline
WA_AVIAK26_STR-DGUELEMP sy-vline
WA_AVIAK26_STR-TBUKRS sy-vline
WA_AVIAK26_STR-TSWENR sy-vline
WA_AVIAK26_STR-TSNKSL sy-vline
WA_AVIAK26_STR-TSEMPSL sy-vline
WA_AVIAK26_STR-SABRG sy-vline
WA_AVIAK26_STR-EQUINUM sy-vline
WA_AVIAK26_STR-XEINHEIT sy-vline
WA_AVIAK26_STR-PROZ sy-vline
WA_AVIAK26_STR-JDISTRIBUTE sy-vline
WA_AVIAK26_STR-VOLWATER sy-vline
WA_AVIAK26_STR-TEMPWATER sy-vline
WA_AVIAK26_STR-HEATVALUE sy-vline
WA_AVIAK26_STR-KBRART sy-vline
WA_AVIAK26_STR-GCONSUMP sy-vline
WA_AVIAK26_STR-QHEATAMOUNT sy-vline
WA_AVIAK26_STR-BCONSUMP sy-vline
WA_AVIAK26_STR-WHEATAMOUNT sy-vline
WA_AVIAK26_STR-WWPROZ sy-vline
WA_AVIAK26_STR-HKVOTYP sy-vline
WA_AVIAK26_STR-RERF sy-vline
WA_AVIAK26_STR-DERF sy-vline
WA_AVIAK26_STR-TERF sy-vline
WA_AVIAK26_STR-REHER sy-vline
WA_AVIAK26_STR-RBEAR sy-vline
WA_AVIAK26_STR-DBEAR sy-vline
WA_AVIAK26_STR-TBEAR sy-vline
WA_AVIAK26_STR-RBHER sy-vline
WA_AVIAK26_STR-OBJNR sy-vline
WA_AVIAK26_STR-MEAS sy-vline
WA_AVIAK26_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.