ABAP Select data from SAP table BBPS_CND_MM_COMPL_EDIDD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP BBPS_CND_MM_COMPL_EDIDD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BBPS_CND_MM_COMPL_EDIDD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the BBPS_CND_MM_COMPL_EDIDD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_BBPS_CND_MM_COMPL_EDIDD TYPE STANDARD TABLE OF BBPS_CND_MM_COMPL_EDIDD, WA_BBPS_CND_MM_COMPL_EDIDD TYPE BBPS_CND_MM_COMPL_EDIDD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <BBPS_CND_MM_COMPL_EDIDD> TYPE BBPS_CND_MM_COMPL_EDIDD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_BBPS_CND_MM_COMPL_EDIDD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM BBPS_CND_MM_COMPL_EDIDD INTO TABLE IT_BBPS_CND_MM_COMPL_EDIDD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM BBPS_CND_MM_COMPL_EDIDD * INTO TABLE @DATA(IT_BBPS_CND_MM_COMPL_EDIDD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_BBPS_CND_MM_COMPL_EDIDD INDEX 1 INTO DATA(WA_BBPS_CND_MM_COMPL_EDIDD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_BBPS_CND_MM_COMPL_EDIDD ASSIGNING <BBPS_CND_MM_COMPL_EDIDD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<BBPS_CND_MM_COMPL_EDIDD>-COND = 1.
<BBPS_CND_MM_COMPL_EDIDD>-CTRL_REC = 1.
<BBPS_CND_MM_COMPL_EDIDD>-MANDT = 1.
<BBPS_CND_MM_COMPL_EDIDD>-DOCNUM = 1.
<BBPS_CND_MM_COMPL_EDIDD>-DOCREL = 1.
ENDLOOP. LOOP AT IT_BBPS_CND_MM_COMPL_EDIDD INTO WA_BBPS_CND_MM_COMPL_EDIDD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_BBPS_CND_MM_COMPL_EDIDD-STATUS, sy-vline,
WA_BBPS_CND_MM_COMPL_EDIDD-DOCTYP, sy-vline,
WA_BBPS_CND_MM_COMPL_EDIDD-DIRECT, sy-vline,
WA_BBPS_CND_MM_COMPL_EDIDD-RCVPOR, sy-vline,
WA_BBPS_CND_MM_COMPL_EDIDD-RCVPRT, sy-vline,
WA_BBPS_CND_MM_COMPL_EDIDD-RCVPRN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BBPS_CND_MM_COMPL_EDIDD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BBPS_CND_MM_COMPL_EDIDD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BBPS_CND_MM_COMPL_EDIDD INTO WA_BBPS_CND_MM_COMPL_EDIDD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RCVPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BBPS_CND_MM_COMPL_EDIDD-RCVPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBPS_CND_MM_COMPL_EDIDD-RCVPRN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SNDPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BBPS_CND_MM_COMPL_EDIDD-SNDPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBPS_CND_MM_COMPL_EDIDD-SNDPRN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EDIPV, internal->external for field RCVPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_BBPS_CND_MM_COMPL_EDIDD-RCVPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBPS_CND_MM_COMPL_EDIDD-RCVPFC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EDIPV, internal->external for field SNDPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_BBPS_CND_MM_COMPL_EDIDD-SNDPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBPS_CND_MM_COMPL_EDIDD-SNDPFC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BBPS_CND_MM_COMPL_EDIDD_STR,
COND TYPE STRING,
CTRL_REC TYPE STRING,
MANDT TYPE STRING,
DOCNUM TYPE STRING,
DOCREL TYPE STRING,
STATUS TYPE STRING,
DOCTYP TYPE STRING,
DIRECT TYPE STRING,
RCVPOR TYPE STRING,
RCVPRT TYPE STRING,
RCVPRN TYPE STRING,
RCVSAD TYPE STRING,
RCVSMN TYPE STRING,
RCVSNA TYPE STRING,
RCVSCA TYPE STRING,
RCVSDF TYPE STRING,
RCVSLF TYPE STRING,
RCVLAD TYPE STRING,
STD TYPE STRING,
STDVRS TYPE STRING,
STDMES TYPE STRING,
MESCOD TYPE STRING,
MESFCT TYPE STRING,
OUTMOD TYPE STRING,
TEST TYPE STRING,
SNDPOR TYPE STRING,
SNDPRT TYPE STRING,
SNDPRN TYPE STRING,
SNDSAD TYPE STRING,
SNDSMN TYPE STRING,
SNDSNA TYPE STRING,
SNDSCA TYPE STRING,
SNDSDF TYPE STRING,
SNDSLF TYPE STRING,
SNDLAD TYPE STRING,
REFINT TYPE STRING,
REFGRP TYPE STRING,
REFMES TYPE STRING,
ARCKEY TYPE STRING,
CREDAT TYPE STRING,
CRETIM TYPE STRING,
MESTYP TYPE STRING,
IDOCTP TYPE STRING,
CIMTYP TYPE STRING,
RCVPFC TYPE STRING,
SNDPFC TYPE STRING,
SERIAL TYPE STRING,
EXPRSS TYPE STRING,
UPDDAT TYPE STRING,
UPDTIM TYPE STRING,
MAXSEGNUM TYPE STRING,
PROCESS_DATA TYPE STRING,
MANDT TYPE STRING,
EVCODE TYPE STRING,
EVENTT TYPE STRING,
EVENTN TYPE STRING,
EDIVR2 TYPE STRING,
EVENXX TYPE STRING,
EVENLX TYPE STRING,
EVENID TYPE STRING,END OF T_EKKO_STR. DATA: WA_BBPS_CND_MM_COMPL_EDIDD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-COND sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-CTRL_REC sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-MANDT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-DOCNUM sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-DOCREL sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-STATUS sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-DOCTYP sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-DIRECT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVPOR sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVPRT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVPRN sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVSAD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVSMN sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVSNA sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVSCA sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVSDF sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVSLF sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVLAD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-STD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-STDVRS sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-STDMES sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-MESCOD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-MESFCT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-OUTMOD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-TEST sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDPOR sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDPRT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDPRN sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDSAD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDSMN sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDSNA sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDSCA sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDSDF sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDSLF sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDLAD sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-REFINT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-REFGRP sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-REFMES sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-ARCKEY sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-CREDAT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-CRETIM sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-MESTYP sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-IDOCTP sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-CIMTYP sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-RCVPFC sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SNDPFC sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-SERIAL sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EXPRSS sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-UPDDAT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-UPDTIM sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-MAXSEGNUM sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-PROCESS_DATA sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-MANDT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EVCODE sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EVENTT sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EVENTN sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EDIVR2 sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EVENXX sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EVENLX sy-vline
WA_BBPS_CND_MM_COMPL_EDIDD_STR-EVENID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.