ABAP Select data from SAP table BIW_TKA01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BIW_TKA01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BIW_TKA01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BIW_TKA01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BIW_TKA01 TYPE STANDARD TABLE OF BIW_TKA01,
      WA_BIW_TKA01 TYPE BIW_TKA01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BIW_TKA01> TYPE BIW_TKA01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BIW_TKA01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BIW_TKA01
  INTO TABLE IT_BIW_TKA01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BIW_TKA01
*  INTO TABLE @DATA(IT_BIW_TKA012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BIW_TKA01 INDEX 1 INTO DATA(WA_BIW_TKA012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BIW_TKA01 ASSIGNING <BIW_TKA01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BIW_TKA01>-MANDT = 1.
<BIW_TKA01>-KOKRS = 1.
<BIW_TKA01>-WAERS = 1.
<BIW_TKA01>-KTOPL = 1.
<BIW_TKA01>-LMONA = 1.
ENDLOOP.

LOOP AT IT_BIW_TKA01 INTO WA_BIW_TKA01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BIW_TKA01-KHINR, sy-vline,
WA_BIW_TKA01-ERKRS, sy-vline,
WA_BIW_TKA01-PHINR, sy-vline,
WA_BIW_TKA01-BPHINR, sy-vline,
WA_BIW_TKA01-PCACURTP, sy-vline,
WA_BIW_TKA01-FIKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BIW_TKA01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BIW_TKA01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BIW_TKA01 INTO WA_BIW_TKA01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BIW_TKA01_STR,
MANDT TYPE STRING,
KOKRS TYPE STRING,
WAERS TYPE STRING,
KTOPL TYPE STRING,
LMONA TYPE STRING,
KHINR TYPE STRING,
ERKRS TYPE STRING,
PHINR TYPE STRING,
BPHINR TYPE STRING,
PCACURTP TYPE STRING,
FIKRS TYPE STRING,END OF T_EKKO_STR. DATA: WA_BIW_TKA01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BIW_TKA01_STR-MANDT sy-vline
WA_BIW_TKA01_STR-KOKRS sy-vline
WA_BIW_TKA01_STR-WAERS sy-vline
WA_BIW_TKA01_STR-KTOPL sy-vline
WA_BIW_TKA01_STR-LMONA sy-vline
WA_BIW_TKA01_STR-KHINR sy-vline
WA_BIW_TKA01_STR-ERKRS sy-vline
WA_BIW_TKA01_STR-PHINR sy-vline
WA_BIW_TKA01_STR-BPHINR sy-vline
WA_BIW_TKA01_STR-PCACURTP sy-vline
WA_BIW_TKA01_STR-FIKRS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.