ABAP Select data from SAP table BOE_S_MD_AR_DETAIL_REP_RESULT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BOE_S_MD_AR_DETAIL_REP_RESULT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BOE_S_MD_AR_DETAIL_REP_RESULT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BOE_S_MD_AR_DETAIL_REP_RESULT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BOE_S_MD_AR_DETAIL_REP_RESULT TYPE STANDARD TABLE OF BOE_S_MD_AR_DETAIL_REP_RESULT,
      WA_BOE_S_MD_AR_DETAIL_REP_RESULT TYPE BOE_S_MD_AR_DETAIL_REP_RESULT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BOE_S_MD_AR_DETAIL_REP_RESULT> TYPE BOE_S_MD_AR_DETAIL_REP_RESULT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BOE_S_MD_AR_DETAIL_REP_RESULT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BOE_S_MD_AR_DETAIL_REP_RESULT
  INTO TABLE IT_BOE_S_MD_AR_DETAIL_REP_RESULT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BOE_S_MD_AR_DETAIL_REP_RESULT
*  INTO TABLE @DATA(IT_BOE_S_MD_AR_DETAIL_REP_RESULT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BOE_S_MD_AR_DETAIL_REP_RESULT INDEX 1 INTO DATA(WA_BOE_S_MD_AR_DETAIL_REP_RESULT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BOE_S_MD_AR_DETAIL_REP_RESULT ASSIGNING <BOE_S_MD_AR_DETAIL_REP_RESULT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BOE_S_MD_AR_DETAIL_REP_RESULT>-BUKRS = 1.
<BOE_S_MD_AR_DETAIL_REP_RESULT>-GSBER = 1.
<BOE_S_MD_AR_DETAIL_REP_RESULT>-BOE_NUMBER = 1.
<BOE_S_MD_AR_DETAIL_REP_RESULT>-BOE_STATUS = 1.
<BOE_S_MD_AR_DETAIL_REP_RESULT>-ZFBDT = 1.
ENDLOOP.

LOOP AT IT_BOE_S_MD_AR_DETAIL_REP_RESULT INTO WA_BOE_S_MD_AR_DETAIL_REP_RESULT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BOE_S_MD_AR_DETAIL_REP_RESULT-KUNNR, sy-vline,
WA_BOE_S_MD_AR_DETAIL_REP_RESULT-WNAME, sy-vline,
WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BOE_RECEIVE_DATE, sy-vline,
WA_BOE_S_MD_AR_DETAIL_REP_RESULT-WDATE, sy-vline,
WA_BOE_S_MD_AR_DETAIL_REP_RESULT-PRCTR, sy-vline,
WA_BOE_S_MD_AR_DETAIL_REP_RESULT-WRBTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BOE_S_MD_AR_DETAIL_REP_RESULT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BOE_S_MD_AR_DETAIL_REP_RESULT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BOE_S_MD_AR_DETAIL_REP_RESULT INTO WA_BOE_S_MD_AR_DETAIL_REP_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOE_CONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BOE_CONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BOE_CONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field BOE_COL_WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BOE_COL_WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BOE_COL_WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU112, internal->external for field DC_NET_AMOUNT CALL FUNCTION 'CONVERSION_EXIT_AU112_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-DC_NET_AMOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-DC_NET_AMOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field LOAN_AMOUNT CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-LOAN_AMOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-LOAN_AMOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field BALANCE CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BALANCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-BALANCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DC_INTEREST CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_BOE_S_MD_AR_DETAIL_REP_RESULT-DC_INTEREST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MD_AR_DETAIL_REP_RESULT-DC_INTEREST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BOE_S_MD_AR_DETAIL_REP_RESULT_STR,
BUKRS TYPE STRING,
GSBER TYPE STRING,
BOE_NUMBER TYPE STRING,
BOE_STATUS TYPE STRING,
ZFBDT TYPE STRING,
KUNNR TYPE STRING,
WNAME TYPE STRING,
BOE_RECEIVE_DATE TYPE STRING,
WDATE TYPE STRING,
PRCTR TYPE STRING,
WRBTR TYPE STRING,
BOE_BLOCK TYPE STRING,
BOE_ACC_BANK_NUMBER TYPE STRING,
BOE_ACC_BANK_COUNTRY TYPE STRING,
BOE_DRAWEE_BANK_NUMBER TYPE STRING,
BOE_DRAWEE_BANK_COUNTRY TYPE STRING,
BOE_DRAWER_BANK_COUNTRY TYPE STRING,
BOE_DRAWER_BANK_NUMBER TYPE STRING,
BOE_FI_STATUS TYPE STRING,
BOE_FILTER_STATUS TYPE STRING,
BOE_ELECTRONIC TYPE STRING,
BOE_TYPE TYPE STRING,
BOE_TYPE_DESC TYPE STRING,
BOE_DESC TYPE STRING,
WAERS TYPE STRING,
BOE_DRAWEE_BANK TYPE STRING,
BOE_DRAWEE_ACCOUNT TYPE STRING,
WBZOG TYPE STRING,
BOE_DRAWER_ACCOUNT TYPE STRING,
CUSTOMER_DESC TYPE STRING,
DB_KEY TYPE STRING,
WBANK TYPE STRING,
BOE_DRAWER_BANK TYPE STRING,
BOE_ACC_BANK TYPE STRING,
BOE_ACC_NAME TYPE STRING,
BOE_COMMENT TYPE STRING,
EN_ENDORSEE TYPE STRING,
EN_ENDORSER TYPE STRING,
BOE_ENDOSE TYPE STRING,
EN_DATE TYPE STRING,
BOE_TRANSACTOR TYPE STRING,
BOE_CONTRACT TYPE STRING,
BOE_OWNER TYPE STRING,
BOE_ENDOSE_ATTR TYPE STRING,
BOE_ENDORSE_NUMBER TYPE STRING,
CUSTODY_HOUSE_BANK TYPE STRING,
CUSTODY_ACCOUNT_ID TYPE STRING,
CUSTODY_BANK_COUNTRY TYPE STRING,
CUSTODY_BANK_NUMBER TYPE STRING,
CUSTODY_BANK TYPE STRING,
BRNCH TYPE STRING,
BANK_ADDR TYPE STRING,
CUSTODY_DATE TYPE STRING,
BOE_CO_DATE TYPE STRING,
BOE_COL_ACCOUNT_ID TYPE STRING,
BOE_COL_BANK_NUMBER TYPE STRING,
BOE_COL_BANK_COUNTRY TYPE STRING,
BOE_COL_HOUSE_BANK TYPE STRING,
BOE_COL_BANK TYPE STRING,
BOE_COL_WRBTR TYPE STRING,
DC_RATE TYPE STRING,
DC_DATE TYPE STRING,
DC_ACCOUNT_ID TYPE STRING,
DC_BANK_NUMBER TYPE STRING,
DC_BANK_COUNTRY TYPE STRING,
DC_HOUSE_BANK TYPE STRING,
DC_BANK TYPE STRING,
DISKT TYPE STRING,
DC_NET_AMOUNT TYPE STRING,
PLEDGE_ACCOUNT_ID TYPE STRING,
PLEDGE_BANK_NUM TYPE STRING,
PLEDGE_BANK_CTRY TYPE STRING,
PLEDGE_HOUSE_BANK TYPE STRING,
PLEDGE_TYPE TYPE STRING,
PLEDGE_DESC TYPE STRING,
PLEDGE_BANK TYPE STRING,
PLEDGE_DATE TYPE STRING,
LOAN_AMOUNT TYPE STRING,
BALANCE TYPE STRING,
FROM_DATE TYPE STRING,
DUE_DATE TYPE STRING,
LOCK_ICON TYPE STRING,
BOE_VERIFIED TYPE STRING,
BOE_NEGOT TYPE STRING,
BOE_FI_STATUS_DESC TYPE STRING,
DC_INTEREST TYPE STRING,
PLEDGE_RATE TYPE STRING,
BOE_CURR_TRANS_ID TYPE STRING,
BOE_CURR_TRANS_NUM TYPE STRING,
BOE_CURR_TRANS_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BUKRS sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-GSBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_STATUS sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-ZFBDT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-KUNNR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-WNAME sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_RECEIVE_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-WDATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PRCTR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-WRBTR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_BLOCK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ACC_BANK_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ACC_BANK_COUNTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWEE_BANK_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWEE_BANK_COUNTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWER_BANK_COUNTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWER_BANK_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_FI_STATUS sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_FILTER_STATUS sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ELECTRONIC sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_TYPE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_TYPE_DESC sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DESC sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-WAERS sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWEE_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWEE_ACCOUNT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-WBZOG sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWER_ACCOUNT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTOMER_DESC sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DB_KEY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-WBANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_DRAWER_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ACC_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ACC_NAME sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COMMENT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-EN_ENDORSEE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-EN_ENDORSER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ENDOSE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-EN_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_TRANSACTOR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_CONTRACT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_OWNER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ENDOSE_ATTR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_ENDORSE_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTODY_HOUSE_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTODY_ACCOUNT_ID sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTODY_BANK_COUNTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTODY_BANK_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTODY_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BRNCH sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BANK_ADDR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-CUSTODY_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_CO_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COL_ACCOUNT_ID sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COL_BANK_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COL_BANK_COUNTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COL_HOUSE_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COL_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_COL_WRBTR sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_RATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_ACCOUNT_ID sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_BANK_NUMBER sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_BANK_COUNTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_HOUSE_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DISKT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_NET_AMOUNT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_ACCOUNT_ID sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_BANK_NUM sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_BANK_CTRY sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_HOUSE_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_TYPE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_DESC sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_BANK sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-LOAN_AMOUNT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BALANCE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-FROM_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DUE_DATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-LOCK_ICON sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_VERIFIED sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_NEGOT sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_FI_STATUS_DESC sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-DC_INTEREST sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-PLEDGE_RATE sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_CURR_TRANS_ID sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_CURR_TRANS_NUM sy-vline
WA_BOE_S_MD_AR_DETAIL_REP_RESULT_STR-BOE_CURR_TRANS_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.