ABAP Select data from SAP table BUS_EI_VERSION_DATA_X into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP BUS_EI_VERSION_DATA_X table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BUS_EI_VERSION_DATA_X. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the BUS_EI_VERSION_DATA_X table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_BUS_EI_VERSION_DATA_X TYPE STANDARD TABLE OF BUS_EI_VERSION_DATA_X, WA_BUS_EI_VERSION_DATA_X TYPE BUS_EI_VERSION_DATA_X, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <BUS_EI_VERSION_DATA_X> TYPE BUS_EI_VERSION_DATA_X. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_BUS_EI_VERSION_DATA_X. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM BUS_EI_VERSION_DATA_X INTO TABLE IT_BUS_EI_VERSION_DATA_X. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM BUS_EI_VERSION_DATA_X * INTO TABLE @DATA(IT_BUS_EI_VERSION_DATA_X2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_BUS_EI_VERSION_DATA_X INDEX 1 INTO DATA(WA_BUS_EI_VERSION_DATA_X2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_BUS_EI_VERSION_DATA_X ASSIGNING <BUS_EI_VERSION_DATA_X>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<BUS_EI_VERSION_DATA_X>-ORGANIZATION = 1.
<BUS_EI_VERSION_DATA_X>-ADDR_VERS = 1.
<BUS_EI_VERSION_DATA_X>-TITLE = 1.
<BUS_EI_VERSION_DATA_X>-NAME = 1.
<BUS_EI_VERSION_DATA_X>-NAME_2 = 1.
ENDLOOP. LOOP AT IT_BUS_EI_VERSION_DATA_X INTO WA_BUS_EI_VERSION_DATA_X. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_BUS_EI_VERSION_DATA_X-NAME_3, sy-vline,
WA_BUS_EI_VERSION_DATA_X-NAME_4, sy-vline,
WA_BUS_EI_VERSION_DATA_X-CONV_NAME, sy-vline,
WA_BUS_EI_VERSION_DATA_X-C_O_NAME, sy-vline,
WA_BUS_EI_VERSION_DATA_X-CITY, sy-vline,
WA_BUS_EI_VERSION_DATA_X-DISTRICT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BUS_EI_VERSION_DATA_X you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BUS_EI_VERSION_DATA_X TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BUS_EI_VERSION_DATA_X INTO WA_BUS_EI_VERSION_DATA_X. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BUS_EI_VERSION_DATA_X_STR,
ORGANIZATION TYPE STRING,
ADDR_VERS TYPE STRING,
TITLE TYPE STRING,
NAME TYPE STRING,
NAME_2 TYPE STRING,
NAME_3 TYPE STRING,
NAME_4 TYPE STRING,
CONV_NAME TYPE STRING,
C_O_NAME TYPE STRING,
CITY TYPE STRING,
DISTRICT TYPE STRING,
PO_BOX_CIT TYPE STRING,
DELIV_DIS TYPE STRING,
STREET TYPE STRING,
HOUSE_NO TYPE STRING,
HOUSE_NO2 TYPE STRING,
HOUSE_NO3 TYPE STRING,
STR_SUPPL1 TYPE STRING,
STR_SUPPL2 TYPE STRING,
STR_SUPPL3 TYPE STRING,
LOCATION TYPE STRING,
BUILDING TYPE STRING,
FLOOR TYPE STRING,
ROOM_NO TYPE STRING,
SORT1 TYPE STRING,
SORT2 TYPE STRING,
HOME_CITY TYPE STRING,
UPDATEFLAG TYPE STRING,
PO_BOX_LOBBY TYPE STRING,
COUNTY TYPE STRING,
TOWNSHIP TYPE STRING,
PERSON TYPE STRING,
ADDR_VERS TYPE STRING,
TITLE_P TYPE STRING,
FIRSTNAME TYPE STRING,
LASTNAME TYPE STRING,
BIRTH_NAME TYPE STRING,
MIDDLENAME TYPE STRING,
SECONDNAME TYPE STRING,
FULLNAME TYPE STRING,
FULLNAME_X TYPE STRING,
TITLE_ACA1 TYPE STRING,
TITLE_ACA2 TYPE STRING,
PREFIX1 TYPE STRING,
PREFIX2 TYPE STRING,
TITLE_SPPL TYPE STRING,
NICKNAME TYPE STRING,
INITIALS TYPE STRING,
NAMEFORMAT TYPE STRING,
NAMCOUNTRY TYPE STRING,
NAMCTRYISO TYPE STRING,
PROFESSION TYPE STRING,
SORT1_P TYPE STRING,
SORT2_P TYPE STRING,
C_O_NAME TYPE STRING,
CITY TYPE STRING,
DISTRICT TYPE STRING,
PO_BOX_CIT TYPE STRING,
DELIV_DIS TYPE STRING,
STREET TYPE STRING,
HOUSE_NO TYPE STRING,
HOUSE_NO2 TYPE STRING,
HOUSE_NO3 TYPE STRING,
STR_SUPPL1 TYPE STRING,
STR_SUPPL2 TYPE STRING,
STR_SUPPL3 TYPE STRING,
LOCATION TYPE STRING,
BUILDING TYPE STRING,
FLOOR TYPE STRING,
ROOM_NO TYPE STRING,
HOME_CITY TYPE STRING,
UPDATEFLAG TYPE STRING,
PO_BOX_LOBBY TYPE STRING,
COUNTY TYPE STRING,
TOWNSHIP TYPE STRING,END OF T_EKKO_STR. DATA: WA_BUS_EI_VERSION_DATA_X_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-ORGANIZATION sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-ADDR_VERS sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TITLE sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAME_2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAME_3 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAME_4 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-CONV_NAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-C_O_NAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-CITY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-DISTRICT sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PO_BOX_CIT sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-DELIV_DIS sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STREET sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOUSE_NO sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOUSE_NO2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOUSE_NO3 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STR_SUPPL1 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STR_SUPPL2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STR_SUPPL3 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-LOCATION sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-BUILDING sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-FLOOR sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-ROOM_NO sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-SORT1 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-SORT2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOME_CITY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-UPDATEFLAG sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PO_BOX_LOBBY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-COUNTY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TOWNSHIP sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PERSON sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-ADDR_VERS sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TITLE_P sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-FIRSTNAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-LASTNAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-BIRTH_NAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-MIDDLENAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-SECONDNAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-FULLNAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-FULLNAME_X sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TITLE_ACA1 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TITLE_ACA2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PREFIX1 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PREFIX2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TITLE_SPPL sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NICKNAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-INITIALS sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAMEFORMAT sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAMCOUNTRY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-NAMCTRYISO sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PROFESSION sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-SORT1_P sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-SORT2_P sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-C_O_NAME sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-CITY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-DISTRICT sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PO_BOX_CIT sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-DELIV_DIS sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STREET sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOUSE_NO sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOUSE_NO2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOUSE_NO3 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STR_SUPPL1 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STR_SUPPL2 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-STR_SUPPL3 sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-LOCATION sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-BUILDING sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-FLOOR sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-ROOM_NO sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-HOME_CITY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-UPDATEFLAG sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-PO_BOX_LOBBY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-COUNTY sy-vline
WA_BUS_EI_VERSION_DATA_X_STR-TOWNSHIP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.