ABAP Select data from SAP table CAD_SRV_ECTR_SW_VERSION into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CAD_SRV_ECTR_SW_VERSION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CAD_SRV_ECTR_SW_VERSION. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CAD_SRV_ECTR_SW_VERSION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CAD_SRV_ECTR_SW_VERSION TYPE STANDARD TABLE OF CAD_SRV_ECTR_SW_VERSION,
      WA_CAD_SRV_ECTR_SW_VERSION TYPE CAD_SRV_ECTR_SW_VERSION,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CAD_SRV_ECTR_SW_VERSION> TYPE CAD_SRV_ECTR_SW_VERSION.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CAD_SRV_ECTR_SW_VERSION.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CAD_SRV_ECTR_SW_VERSION
  INTO TABLE IT_CAD_SRV_ECTR_SW_VERSION.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CAD_SRV_ECTR_SW_VERSION
*  INTO TABLE @DATA(IT_CAD_SRV_ECTR_SW_VERSION2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CAD_SRV_ECTR_SW_VERSION INDEX 1 INTO DATA(WA_CAD_SRV_ECTR_SW_VERSION2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CAD_SRV_ECTR_SW_VERSION ASSIGNING <CAD_SRV_ECTR_SW_VERSION>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CAD_SRV_ECTR_SW_VERSION>-DB_KEY = 1.
<CAD_SRV_ECTR_SW_VERSION>-DB_KEY_PROJECT = 1.
<CAD_SRV_ECTR_SW_VERSION>-VERSION = 1.
<CAD_SRV_ECTR_SW_VERSION>-BUILD_URL = 1.
<CAD_SRV_ECTR_SW_VERSION>-BUILD_COUNTER = 1.
ENDLOOP.

LOOP AT IT_CAD_SRV_ECTR_SW_VERSION INTO WA_CAD_SRV_ECTR_SW_VERSION.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CAD_SRV_ECTR_SW_VERSION-BUILD_TIMESTAMP, sy-vline,
WA_CAD_SRV_ECTR_SW_VERSION-DOCUMENTTYPE, sy-vline,
WA_CAD_SRV_ECTR_SW_VERSION-DOCUMENTNUMBER, sy-vline,
WA_CAD_SRV_ECTR_SW_VERSION-DOCUMENTVERSION, sy-vline,
WA_CAD_SRV_ECTR_SW_VERSION-DOCUMENTPART, sy-vline,
WA_CAD_SRV_ECTR_SW_VERSION-UPDATE_INDICATOR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CAD_SRV_ECTR_SW_VERSION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CAD_SRV_ECTR_SW_VERSION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CAD_SRV_ECTR_SW_VERSION INTO WA_CAD_SRV_ECTR_SW_VERSION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOCUMENTNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CAD_SRV_ECTR_SW_VERSION-DOCUMENTNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CAD_SRV_ECTR_SW_VERSION-DOCUMENTNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CAD_SRV_ECTR_SW_VERSION_STR,
DB_KEY TYPE STRING,
DB_KEY_PROJECT TYPE STRING,
VERSION TYPE STRING,
BUILD_URL TYPE STRING,
BUILD_COUNTER TYPE STRING,
BUILD_TIMESTAMP TYPE STRING,
DOCUMENTTYPE TYPE STRING,
DOCUMENTNUMBER TYPE STRING,
DOCUMENTVERSION TYPE STRING,
DOCUMENTPART TYPE STRING,
UPDATE_INDICATOR TYPE STRING,
DESCRIPTION TYPE STRING,
CREATED_AT TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
NEWEST_VERSION_FLAG TYPE STRING,
TAB_INDEX TYPE STRING,END OF T_EKKO_STR. DATA: WA_CAD_SRV_ECTR_SW_VERSION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DB_KEY sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DB_KEY_PROJECT sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-VERSION sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-BUILD_URL sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-BUILD_COUNTER sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-BUILD_TIMESTAMP sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DOCUMENTTYPE sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DOCUMENTNUMBER sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DOCUMENTVERSION sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DOCUMENTPART sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-UPDATE_INDICATOR sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-DESCRIPTION sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-CREATED_AT sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-CREATED_BY sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-CHANGED_AT sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-CHANGED_BY sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-NEWEST_VERSION_FLAG sy-vline
WA_CAD_SRV_ECTR_SW_VERSION_STR-TAB_INDEX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.