ABAP Select data from SAP table CCIHS_WAHAPI into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCIHS_WAHAPI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCIHS_WAHAPI. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CCIHS_WAHAPI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CCIHS_WAHAPI TYPE STANDARD TABLE OF CCIHS_WAHAPI, WA_CCIHS_WAHAPI TYPE CCIHS_WAHAPI, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CCIHS_WAHAPI> TYPE CCIHS_WAHAPI. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CCIHS_WAHAPI. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CCIHS_WAHAPI INTO TABLE IT_CCIHS_WAHAPI. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CCIHS_WAHAPI * INTO TABLE @DATA(IT_CCIHS_WAHAPI2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CCIHS_WAHAPI INDEX 1 INTO DATA(WA_CCIHS_WAHAPI2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CCIHS_WAHAPI ASSIGNING <CCIHS_WAHAPI>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCIHS_WAHAPI>-MANDT = 1.
<CCIHS_WAHAPI>-RECN = 1.
<CCIHS_WAHAPI>-ACTN = 1.
<CCIHS_WAHAPI>-VALFR = 1.
<CCIHS_WAHAPI>-VALTO = 1.
ENDLOOP. LOOP AT IT_CCIHS_WAHAPI INTO WA_CCIHS_WAHAPI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CCIHS_WAHAPI-AENNR, sy-vline,
WA_CCIHS_WAHAPI-DELFLG, sy-vline,
WA_CCIHS_WAHAPI-PARKFLG, sy-vline,
WA_CCIHS_WAHAPI-CRDAT, sy-vline,
WA_CCIHS_WAHAPI-CRNAM, sy-vline,
WA_CCIHS_WAHAPI-UPDDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCIHS_WAHAPI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCIHS_WAHAPI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCIHS_WAHAPI INTO WA_CCIHS_WAHAPI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-RECN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-ACTN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-OWNID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-RECNROOT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CHRID, internal->external for field WAID CALL FUNCTION 'CONVERSION_EXIT_CHRID_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-WAID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-WAID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field MTNLANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-MTNLANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-MTNLANGU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNTWAH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-RECNTWAH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-RECNTWAH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WACOSTAC1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAHAPI-WACOSTAC1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAHAPI-WACOSTAC1.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCIHS_WAHAPI_STR,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
OBJNR TYPE STRING,
WAID TYPE STRING,
WATYPE TYPE STRING,
WASTAT TYPE STRING,
WAINITSTAT TYPE STRING,
WAVERS TYPE STRING,
AUTHGRP TYPE STRING,
RVLID TYPE STRING,
MTNLANGU TYPE STRING,
RECNTWAH TYPE STRING,
WAPLANT TYPE STRING,
WACOORD TYPE STRING,
WACOSTAC1 TYPE STRING,
WACTRAREA TYPE STRING,
WACOCODE TYPE STRING,
PTUSAGEFLG TYPE STRING,
OVERALLRAT TYPE STRING,
RECEIVEDRAT TYPE STRING,
ERRORMODE TYPE STRING,
ERRORINFO TYPE STRING,
ERRORCLASS TYPE STRING,
ERRORPARAM TYPE STRING,
LOGLOCKMOD TYPE STRING,
EXTINFO TYPE STRING,
LINEMOD TYPE STRING,
KEYDRAWNFLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCIHS_WAHAPI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCIHS_WAHAPI_STR-MANDT sy-vline
WA_CCIHS_WAHAPI_STR-RECN sy-vline
WA_CCIHS_WAHAPI_STR-ACTN sy-vline
WA_CCIHS_WAHAPI_STR-VALFR sy-vline
WA_CCIHS_WAHAPI_STR-VALTO sy-vline
WA_CCIHS_WAHAPI_STR-AENNR sy-vline
WA_CCIHS_WAHAPI_STR-DELFLG sy-vline
WA_CCIHS_WAHAPI_STR-PARKFLG sy-vline
WA_CCIHS_WAHAPI_STR-CRDAT sy-vline
WA_CCIHS_WAHAPI_STR-CRNAM sy-vline
WA_CCIHS_WAHAPI_STR-UPDDAT sy-vline
WA_CCIHS_WAHAPI_STR-UPDNAM sy-vline
WA_CCIHS_WAHAPI_STR-SRSID sy-vline
WA_CCIHS_WAHAPI_STR-OWNID sy-vline
WA_CCIHS_WAHAPI_STR-RECNROOT sy-vline
WA_CCIHS_WAHAPI_STR-OBJNR sy-vline
WA_CCIHS_WAHAPI_STR-WAID sy-vline
WA_CCIHS_WAHAPI_STR-WATYPE sy-vline
WA_CCIHS_WAHAPI_STR-WASTAT sy-vline
WA_CCIHS_WAHAPI_STR-WAINITSTAT sy-vline
WA_CCIHS_WAHAPI_STR-WAVERS sy-vline
WA_CCIHS_WAHAPI_STR-AUTHGRP sy-vline
WA_CCIHS_WAHAPI_STR-RVLID sy-vline
WA_CCIHS_WAHAPI_STR-MTNLANGU sy-vline
WA_CCIHS_WAHAPI_STR-RECNTWAH sy-vline
WA_CCIHS_WAHAPI_STR-WAPLANT sy-vline
WA_CCIHS_WAHAPI_STR-WACOORD sy-vline
WA_CCIHS_WAHAPI_STR-WACOSTAC1 sy-vline
WA_CCIHS_WAHAPI_STR-WACTRAREA sy-vline
WA_CCIHS_WAHAPI_STR-WACOCODE sy-vline
WA_CCIHS_WAHAPI_STR-PTUSAGEFLG sy-vline
WA_CCIHS_WAHAPI_STR-OVERALLRAT sy-vline
WA_CCIHS_WAHAPI_STR-RECEIVEDRAT sy-vline
WA_CCIHS_WAHAPI_STR-ERRORMODE sy-vline
WA_CCIHS_WAHAPI_STR-ERRORINFO sy-vline
WA_CCIHS_WAHAPI_STR-ERRORCLASS sy-vline
WA_CCIHS_WAHAPI_STR-ERRORPARAM sy-vline
WA_CCIHS_WAHAPI_STR-LOGLOCKMOD sy-vline
WA_CCIHS_WAHAPI_STR-EXTINFO sy-vline
WA_CCIHS_WAHAPI_STR-LINEMOD sy-vline
WA_CCIHS_WAHAPI_STR-KEYDRAWNFLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.