ABAP Select data from SAP table CCMSBI_WASTAT_SEGM_HTPCD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCMSBI_WASTAT_SEGM_HTPCD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCMSBI_WASTAT_SEGM_HTPCD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CCMSBI_WASTAT_SEGM_HTPCD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CCMSBI_WASTAT_SEGM_HTPCD TYPE STANDARD TABLE OF CCMSBI_WASTAT_SEGM_HTPCD, WA_CCMSBI_WASTAT_SEGM_HTPCD TYPE CCMSBI_WASTAT_SEGM_HTPCD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CCMSBI_WASTAT_SEGM_HTPCD> TYPE CCMSBI_WASTAT_SEGM_HTPCD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CCMSBI_WASTAT_SEGM_HTPCD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CCMSBI_WASTAT_SEGM_HTPCD INTO TABLE IT_CCMSBI_WASTAT_SEGM_HTPCD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CCMSBI_WASTAT_SEGM_HTPCD * INTO TABLE @DATA(IT_CCMSBI_WASTAT_SEGM_HTPCD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CCMSBI_WASTAT_SEGM_HTPCD INDEX 1 INTO DATA(WA_CCMSBI_WASTAT_SEGM_HTPCD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CCMSBI_WASTAT_SEGM_HTPCD ASSIGNING <CCMSBI_WASTAT_SEGM_HTPCD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCMSBI_WASTAT_SEGM_HTPCD>-CONNECTION_ID = 1.
<CCMSBI_WASTAT_SEGM_HTPCD>-CALL_NUMBER_D = 1.
<CCMSBI_WASTAT_SEGM_HTPCD>-CALL_NUMBER_C = 1.
<CCMSBI_WASTAT_SEGM_HTPCD>-PROTOCOL = 1.
<CCMSBI_WASTAT_SEGM_HTPCD>-HOST = 1.
ENDLOOP. LOOP AT IT_CCMSBI_WASTAT_SEGM_HTPCD INTO WA_CCMSBI_WASTAT_SEGM_HTPCD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CCMSBI_WASTAT_SEGM_HTPCD-PORT, sy-vline,
WA_CCMSBI_WASTAT_SEGM_HTPCD-METHOD, sy-vline,
WA_CCMSBI_WASTAT_SEGM_HTPCD-DESTINATION_NAME, sy-vline,
WA_CCMSBI_WASTAT_SEGM_HTPCD-INSTANCE_NAME, sy-vline,
WA_CCMSBI_WASTAT_SEGM_HTPCD-P_INSTANCE_NAME, sy-vline,
WA_CCMSBI_WASTAT_SEGM_HTPCD-P_RELEASE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCMSBI_WASTAT_SEGM_HTPCD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCMSBI_WASTAT_SEGM_HTPCD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCMSBI_WASTAT_SEGM_HTPCD INTO WA_CCMSBI_WASTAT_SEGM_HTPCD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCMSBI_WASTAT_SEGM_HTPCD_STR,
CONNECTION_ID TYPE STRING,
CALL_NUMBER_D TYPE STRING,
CALL_NUMBER_C TYPE STRING,
PROTOCOL TYPE STRING,
HOST TYPE STRING,
PORT TYPE STRING,
METHOD TYPE STRING,
DESTINATION_NAME TYPE STRING,
INSTANCE_NAME TYPE STRING,
P_INSTANCE_NAME TYPE STRING,
P_RELEASE TYPE STRING,
P_IP_ADDRESS TYPE STRING,
CALL_TIME_D TYPE STRING,
CALL_TIME_C TYPE STRING,
IDLE_TIME_D TYPE STRING,
IDLE_TIME_C TYPE STRING,
DATA_SEND_D TYPE STRING,
D_SEND_TIME_D TYPE STRING,
DATA_SEND_C TYPE STRING,
D_SEND_TIME_C TYPE STRING,
D_RECEIVE_D TYPE STRING,
D_RECEIVE_TIME_D TYPE STRING,
D_RECEIVE_C TYPE STRING,
D_RECEIVE_TIME_C TYPE STRING,
TRANSACTION_CODE TYPE STRING,
PROGRAM_NAME TYPE STRING,
P_EXEC_TIME_D TYPE STRING,
P_EXEC_TIME_C TYPE STRING,
P_ENGINE_TYPE TYPE STRING,
P_USER_NAME TYPE STRING,
P_CLIENT_NUMBER TYPE STRING,
PATH TYPE STRING,
END_SEC_COUNT TYPE STRING,
LOGRECID TYPE STRING,
P_ENG_TYPE_TXT TYPE STRING,
PROTOCOL_TXT TYPE STRING,
METHOD_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCMSBI_WASTAT_SEGM_HTPCD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-CONNECTION_ID sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-CALL_NUMBER_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-CALL_NUMBER_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-PROTOCOL sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-HOST sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-PORT sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-METHOD sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-DESTINATION_NAME sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-INSTANCE_NAME sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_INSTANCE_NAME sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_RELEASE sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_IP_ADDRESS sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-CALL_TIME_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-CALL_TIME_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-IDLE_TIME_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-IDLE_TIME_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-DATA_SEND_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-D_SEND_TIME_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-DATA_SEND_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-D_SEND_TIME_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-D_RECEIVE_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-D_RECEIVE_TIME_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-D_RECEIVE_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-D_RECEIVE_TIME_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-TRANSACTION_CODE sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-PROGRAM_NAME sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_EXEC_TIME_D sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_EXEC_TIME_C sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_ENGINE_TYPE sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_USER_NAME sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_CLIENT_NUMBER sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-PATH sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-END_SEC_COUNT sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-LOGRECID sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-P_ENG_TYPE_TXT sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-PROTOCOL_TXT sy-vline
WA_CCMSBI_WASTAT_SEGM_HTPCD_STR-METHOD_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.