ABAP Select data from SAP table CCRRSUBSTSLCTP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCRRSUBSTSLCTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCRRSUBSTSLCTP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CCRRSUBSTSLCTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CCRRSUBSTSLCTP TYPE STANDARD TABLE OF CCRRSUBSTSLCTP, WA_CCRRSUBSTSLCTP TYPE CCRRSUBSTSLCTP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CCRRSUBSTSLCTP> TYPE CCRRSUBSTSLCTP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CCRRSUBSTSLCTP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CCRRSUBSTSLCTP INTO TABLE IT_CCRRSUBSTSLCTP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CCRRSUBSTSLCTP * INTO TABLE @DATA(IT_CCRRSUBSTSLCTP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CCRRSUBSTSLCTP INDEX 1 INTO DATA(WA_CCRRSUBSTSLCTP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CCRRSUBSTSLCTP ASSIGNING <CCRRSUBSTSLCTP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCRRSUBSTSLCTP>-MANDT = 1.
<CCRRSUBSTSLCTP>-CMPLRQRSLTUUID = 1.
<CCRRSUBSTSLCTP>-ACTIVECMPLRQRSLTUUID = 1.
<CCRRSUBSTSLCTP>-SUBSTANCEUUID = 1.
<CCRRSUBSTSLCTP>-CMPLRQVERSUUID = 1.
ENDLOOP. LOOP AT IT_CCRRSUBSTSLCTP INTO WA_CCRRSUBSTSLCTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CCRRSUBSTSLCTP-COMPLIANCEREQUIREMENT, sy-vline,
WA_CCRRSUBSTSLCTP-CMPLRQRSLTMANUALSTATUS, sy-vline,
WA_CCRRSUBSTSLCTP-CMPLRQRSLTMANUALCMPLNCSTSNAME, sy-vline,
WA_CCRRSUBSTSLCTP-PROCESSOR, sy-vline,
WA_CCRRSUBSTSLCTP-CMPLRQRSLTPROCESSORNAME, sy-vline,
WA_CCRRSUBSTSLCTP-CMPLRQRSLTSTATUSREMARK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCRRSUBSTSLCTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCRRSUBSTSLCTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCRRSUBSTSLCTP INTO WA_CCRRSUBSTSLCTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PROCESSOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCRRSUBSTSLCTP-PROCESSOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRRSUBSTSLCTP-PROCESSOR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCRRSUBSTSLCTP_STR,
MANDT TYPE STRING,
CMPLRQRSLTUUID TYPE STRING,
ACTIVECMPLRQRSLTUUID TYPE STRING,
SUBSTANCEUUID TYPE STRING,
CMPLRQVERSUUID TYPE STRING,
COMPLIANCEREQUIREMENT TYPE STRING,
CMPLRQRSLTMANUALSTATUS TYPE STRING,
CMPLRQRSLTMANUALCMPLNCSTSNAME TYPE STRING,
PROCESSOR TYPE STRING,
CMPLRQRSLTPROCESSORNAME TYPE STRING,
CMPLRQRSLTSTATUSREMARK TYPE STRING,
SUBSTANCENAME TYPE STRING,
CASNUMBER TYPE STRING,
CMPLRQVERSNAME TYPE STRING,
CMPLRQVERSNMBROFEXEMPTIONS TYPE STRING,
CMPLRQVERSNMBROFACTIONS TYPE STRING,
CMPLRQVERSINVTRYLISTISEXISTING TYPE STRING,
CMPLRQVERSRSTRCNLISTISEXISTING TYPE STRING,
CMPLRQRSLTPRELIMCMPLNCSTS TYPE STRING,
CMPLRQRSLTPRELIMCMPLNCSTSNAME TYPE STRING,
CMPLRQRSLTCMPLNCSTSCRITICALITY TYPE STRING,
COMPANYSUBSTANCENAVGNLINK TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCRRSUBSTSLCTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCRRSUBSTSLCTP_STR-MANDT sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTUUID sy-vline
WA_CCRRSUBSTSLCTP_STR-ACTIVECMPLRQRSLTUUID sy-vline
WA_CCRRSUBSTSLCTP_STR-SUBSTANCEUUID sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQVERSUUID sy-vline
WA_CCRRSUBSTSLCTP_STR-COMPLIANCEREQUIREMENT sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTMANUALSTATUS sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTMANUALCMPLNCSTSNAME sy-vline
WA_CCRRSUBSTSLCTP_STR-PROCESSOR sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTPROCESSORNAME sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTSTATUSREMARK sy-vline
WA_CCRRSUBSTSLCTP_STR-SUBSTANCENAME sy-vline
WA_CCRRSUBSTSLCTP_STR-CASNUMBER sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQVERSNAME sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQVERSNMBROFEXEMPTIONS sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQVERSNMBROFACTIONS sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQVERSINVTRYLISTISEXISTING sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQVERSRSTRCNLISTISEXISTING sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTPRELIMCMPLNCSTS sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTPRELIMCMPLNCSTSNAME sy-vline
WA_CCRRSUBSTSLCTP_STR-CMPLRQRSLTCMPLNCSTSCRITICALITY sy-vline
WA_CCRRSUBSTSLCTP_STR-COMPANYSUBSTANCENAVGNLINK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.