ABAP Select data from SAP table CDFSPOSASSGMTOTP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CDFSPOSASSGMTOTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CDFSPOSASSGMTOTP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CDFSPOSASSGMTOTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CDFSPOSASSGMTOTP TYPE STANDARD TABLE OF CDFSPOSASSGMTOTP, WA_CDFSPOSASSGMTOTP TYPE CDFSPOSASSGMTOTP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CDFSPOSASSGMTOTP> TYPE CDFSPOSASSGMTOTP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CDFSPOSASSGMTOTP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CDFSPOSASSGMTOTP INTO TABLE IT_CDFSPOSASSGMTOTP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CDFSPOSASSGMTOTP * INTO TABLE @DATA(IT_CDFSPOSASSGMTOTP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CDFSPOSASSGMTOTP INDEX 1 INTO DATA(WA_CDFSPOSASSGMTOTP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CDFSPOSASSGMTOTP ASSIGNING <CDFSPOSASSGMTOTP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CDFSPOSASSGMTOTP>-MANDT = 1.
<CDFSPOSASSGMTOTP>-DFSASSGMTSUBUUID = 1.
<CDFSPOSASSGMTOTP>-DFSASSGMTUUID = 1.
<CDFSPOSASSGMTOTP>-FLXBLMATLPLNGOBJVARIANTUUID = 1.
<CDFSPOSASSGMTOTP>-FLXBLMATLPLNGOBJECTUUID = 1.
ENDLOOP. LOOP AT IT_CDFSPOSASSGMTOTP INTO WA_CDFSPOSASSGMTOTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CDFSPOSASSGMTOTP-FLXMTPLOBJVARIANTACCOGPRTUUID, sy-vline,
WA_CDFSPOSASSGMTOTP-FLXMTPLOBJVARACCOGPARTITEM, sy-vline,
WA_CDFSPOSASSGMTOTP-FLXBLMATLPLNGOBJECTID, sy-vline,
WA_CDFSPOSASSGMTOTP-FLXMTPLOBJVARACCOGPRTREFOBJID, sy-vline,
WA_CDFSPOSASSGMTOTP-FLXBLMATLPLNGOBJDESCRIPTION, sy-vline,
WA_CDFSPOSASSGMTOTP-FLXMTPLOBJVARACCOGPRTREFVARID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CDFSPOSASSGMTOTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CDFSPOSASSGMTOTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CDFSPOSASSGMTOTP INTO WA_CDFSPOSASSGMTOTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CDFSPOSASSGMTOTP_STR,
MANDT TYPE STRING,
DFSASSGMTSUBUUID TYPE STRING,
DFSASSGMTUUID TYPE STRING,
FLXBLMATLPLNGOBJVARIANTUUID TYPE STRING,
FLXBLMATLPLNGOBJECTUUID TYPE STRING,
FLXMTPLOBJVARIANTACCOGPRTUUID TYPE STRING,
FLXMTPLOBJVARACCOGPARTITEM TYPE STRING,
FLXBLMATLPLNGOBJECTID TYPE STRING,
FLXMTPLOBJVARACCOGPRTREFOBJID TYPE STRING,
FLXBLMATLPLNGOBJDESCRIPTION TYPE STRING,
FLXMTPLOBJVARACCOGPRTREFVARID TYPE STRING,
FLXBLMATLPLNGOBJVARIANTDESC TYPE STRING,
FLXMTPLOBJVARACCOGPRTAUTHZDVAL TYPE STRING,
FLXMTPLOBJVARACCOGPARTASSGMT TYPE STRING,
DFSASSGMTCORRECTIONVALUE TYPE STRING,
DFSASSGMTSOURCETYPE TYPE STRING,
DFSASSGMTTYPE TYPE STRING,
DFSASSGMTSTATUSCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CDFSPOSASSGMTOTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CDFSPOSASSGMTOTP_STR-MANDT sy-vline
WA_CDFSPOSASSGMTOTP_STR-DFSASSGMTSUBUUID sy-vline
WA_CDFSPOSASSGMTOTP_STR-DFSASSGMTUUID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXBLMATLPLNGOBJVARIANTUUID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXBLMATLPLNGOBJECTUUID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXMTPLOBJVARIANTACCOGPRTUUID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXMTPLOBJVARACCOGPARTITEM sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXBLMATLPLNGOBJECTID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXMTPLOBJVARACCOGPRTREFOBJID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXBLMATLPLNGOBJDESCRIPTION sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXMTPLOBJVARACCOGPRTREFVARID sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXBLMATLPLNGOBJVARIANTDESC sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXMTPLOBJVARACCOGPRTAUTHZDVAL sy-vline
WA_CDFSPOSASSGMTOTP_STR-FLXMTPLOBJVARACCOGPARTASSGMT sy-vline
WA_CDFSPOSASSGMTOTP_STR-DFSASSGMTCORRECTIONVALUE sy-vline
WA_CDFSPOSASSGMTOTP_STR-DFSASSGMTSOURCETYPE sy-vline
WA_CDFSPOSASSGMTOTP_STR-DFSASSGMTTYPE sy-vline
WA_CDFSPOSASSGMTOTP_STR-DFSASSGMTSTATUSCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.