ABAP Select data from SAP table CFB_BACKFLUSH into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFB_BACKFLUSH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFB_BACKFLUSH. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CFB_BACKFLUSH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CFB_BACKFLUSH TYPE STANDARD TABLE OF CFB_BACKFLUSH, WA_CFB_BACKFLUSH TYPE CFB_BACKFLUSH, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CFB_BACKFLUSH> TYPE CFB_BACKFLUSH. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CFB_BACKFLUSH. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CFB_BACKFLUSH INTO TABLE IT_CFB_BACKFLUSH. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CFB_BACKFLUSH * INTO TABLE @DATA(IT_CFB_BACKFLUSH2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CFB_BACKFLUSH INDEX 1 INTO DATA(WA_CFB_BACKFLUSH2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CFB_BACKFLUSH ASSIGNING <CFB_BACKFLUSH>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFB_BACKFLUSH>-MANDT = 1.
<CFB_BACKFLUSH>-RSNUM = 1.
<CFB_BACKFLUSH>-RSPOS = 1.
<CFB_BACKFLUSH>-CHARG = 1.
<CFB_BACKFLUSH>-MATNR = 1.
ENDLOOP. LOOP AT IT_CFB_BACKFLUSH INTO WA_CFB_BACKFLUSH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CFB_BACKFLUSH-WERKS, sy-vline,
WA_CFB_BACKFLUSH-LGORT, sy-vline,
WA_CFB_BACKFLUSH-AUFNR, sy-vline,
WA_CFB_BACKFLUSH-AUFTYP, sy-vline,
WA_CFB_BACKFLUSH-ERSDA_BATCH, sy-vline,
WA_CFB_BACKFLUSH-KZKUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CFB_BACKFLUSH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFB_BACKFLUSH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFB_BACKFLUSH INTO WA_CFB_BACKFLUSH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CFB_BACKFLUSH-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CFB_BACKFLUSH-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CFB_BACKFLUSH-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CFB_BACKFLUSH-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field GM_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CFB_BACKFLUSH-GM_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CFB_BACKFLUSH-GM_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFB_BACKFLUSH_STR,
MANDT TYPE STRING,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
CHARG TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
AUFNR TYPE STRING,
AUFTYP TYPE STRING,
ERSDA_BATCH TYPE STRING,
KZKUP TYPE STRING,
GM_QTY TYPE STRING,
GM_UOM TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFB_BACKFLUSH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFB_BACKFLUSH_STR-MANDT sy-vline
WA_CFB_BACKFLUSH_STR-RSNUM sy-vline
WA_CFB_BACKFLUSH_STR-RSPOS sy-vline
WA_CFB_BACKFLUSH_STR-CHARG sy-vline
WA_CFB_BACKFLUSH_STR-MATNR sy-vline
WA_CFB_BACKFLUSH_STR-WERKS sy-vline
WA_CFB_BACKFLUSH_STR-LGORT sy-vline
WA_CFB_BACKFLUSH_STR-AUFNR sy-vline
WA_CFB_BACKFLUSH_STR-AUFTYP sy-vline
WA_CFB_BACKFLUSH_STR-ERSDA_BATCH sy-vline
WA_CFB_BACKFLUSH_STR-KZKUP sy-vline
WA_CFB_BACKFLUSH_STR-GM_QTY sy-vline
WA_CFB_BACKFLUSH_STR-GM_UOM sy-vline
WA_CFB_BACKFLUSH_STR-ERDAT sy-vline
WA_CFB_BACKFLUSH_STR-ERZEIT sy-vline
WA_CFB_BACKFLUSH_STR-ERNAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.