ABAP Select data from SAP table CFD_L_RT_SO_OP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFD_L_RT_SO_OP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFD_L_RT_SO_OP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CFD_L_RT_SO_OP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CFD_L_RT_SO_OP TYPE STANDARD TABLE OF CFD_L_RT_SO_OP, WA_CFD_L_RT_SO_OP TYPE CFD_L_RT_SO_OP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CFD_L_RT_SO_OP> TYPE CFD_L_RT_SO_OP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CFD_L_RT_SO_OP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CFD_L_RT_SO_OP INTO TABLE IT_CFD_L_RT_SO_OP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CFD_L_RT_SO_OP * INTO TABLE @DATA(IT_CFD_L_RT_SO_OP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CFD_L_RT_SO_OP INDEX 1 INTO DATA(WA_CFD_L_RT_SO_OP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CFD_L_RT_SO_OP ASSIGNING <CFD_L_RT_SO_OP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFD_L_RT_SO_OP>-SERVICE_INTERFACE_NAME = 1.
<CFD_L_RT_SO_OP>-OPERATION = 1.
<CFD_L_RT_SO_OP>-MESSAGE_DIRECTION = 1.
<CFD_L_RT_SO_OP>-MDR_DATA_TYPE_NAME = 1.
<CFD_L_RT_SO_OP>-IS_EXTENDED = 1.
ENDLOOP. LOOP AT IT_CFD_L_RT_SO_OP INTO WA_CFD_L_RT_SO_OP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, ENDLOOP. *Add any further fields from structure WA_CFD_L_RT_SO_OP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFD_L_RT_SO_OP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFD_L_RT_SO_OP INTO WA_CFD_L_RT_SO_OP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFD_L_RT_SO_OP_STR,
SERVICE_INTERFACE_NAME TYPE STRING,
OPERATION TYPE STRING,
MESSAGE_DIRECTION TYPE STRING,
MDR_DATA_TYPE_NAME TYPE STRING,
IS_EXTENDED TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFD_L_RT_SO_OP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFD_L_RT_SO_OP_STR-SERVICE_INTERFACE_NAME sy-vline
WA_CFD_L_RT_SO_OP_STR-OPERATION sy-vline
WA_CFD_L_RT_SO_OP_STR-MESSAGE_DIRECTION sy-vline
WA_CFD_L_RT_SO_OP_STR-MDR_DATA_TYPE_NAME sy-vline
WA_CFD_L_RT_SO_OP_STR-IS_EXTENDED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.