ABAP Select data from SAP table CINSPUSGESGLRSLT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CINSPUSGESGLRSLT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CINSPUSGESGLRSLT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CINSPUSGESGLRSLT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CINSPUSGESGLRSLT TYPE STANDARD TABLE OF CINSPUSGESGLRSLT,
      WA_CINSPUSGESGLRSLT TYPE CINSPUSGESGLRSLT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CINSPUSGESGLRSLT> TYPE CINSPUSGESGLRSLT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CINSPUSGESGLRSLT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CINSPUSGESGLRSLT
  INTO TABLE IT_CINSPUSGESGLRSLT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CINSPUSGESGLRSLT
*  INTO TABLE @DATA(IT_CINSPUSGESGLRSLT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CINSPUSGESGLRSLT INDEX 1 INTO DATA(WA_CINSPUSGESGLRSLT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CINSPUSGESGLRSLT ASSIGNING <CINSPUSGESGLRSLT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CINSPUSGESGLRSLT>-MANDT = 1.
<CINSPUSGESGLRSLT>-INSPECTIONLOT = 1.
<CINSPUSGESGLRSLT>-INSPPLANOPERATIONINTERNALID = 1.
<CINSPUSGESGLRSLT>-INSPECTIONCHARACTERISTIC = 1.
<CINSPUSGESGLRSLT>-INSPECTIONSUBSETINTERNALID = 1.
ENDLOOP.

LOOP AT IT_CINSPUSGESGLRSLT INTO WA_CINSPUSGESGLRSLT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CINSPUSGESGLRSLT-INSPECTIONOPERATION, sy-vline,
WA_CINSPUSGESGLRSLT-INSPRESULTVALUEINTERNALID, sy-vline,
WA_CINSPUSGESGLRSLT-INSPSPECISQUANTITATIVE, sy-vline,
WA_CINSPUSGESGLRSLT-INSPSPECRECORDINGTYPE, sy-vline,
WA_CINSPUSGESGLRSLT-INSPSPECISMEASUREDVALUERQD, sy-vline,
WA_CINSPUSGESGLRSLT-INSPECTIONSPECIFICATIONUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CINSPUSGESGLRSLT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CINSPUSGESGLRSLT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CINSPUSGESGLRSLT INTO WA_CINSPUSGESGLRSLT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPUSGESGLRSLT-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPUSGESGLRSLT-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CINSPUSGESGLRSLT-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPUSGESGLRSLT-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CINSPUSGESGLRSLT_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
INSPRESULTVALUEINTERNALID TYPE STRING,
INSPSPECISQUANTITATIVE TYPE STRING,
INSPSPECRECORDINGTYPE TYPE STRING,
INSPSPECISMEASUREDVALUERQD TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
USAGEDECISIONCODECRITICALITY TYPE STRING,
INSPSPECDECIMALPLACES TYPE STRING,
INSPRESULTHASMEASUREDVALUE TYPE STRING,
CHARACTERISTICATTRIBUTECODEGRP TYPE STRING,
INSPECTIONVALUATIONRESULT TYPE STRING,
INSPECTIONRESULTMEASUREDVALUE TYPE STRING,
CHARACTERISTICATTRIBUTECODE TYPE STRING,
CHARACTERISTICATTRIBUTECODETXT TYPE STRING,
CHANGEDDATETIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CINSPUSGESGLRSLT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CINSPUSGESGLRSLT_STR-MANDT sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONLOT sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONOPERATION sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPRESULTVALUEINTERNALID sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPSPECISQUANTITATIVE sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPSPECRECORDINGTYPE sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPSPECISMEASUREDVALUERQD sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_CINSPUSGESGLRSLT_STR-USAGEDECISIONCODECRITICALITY sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPSPECDECIMALPLACES sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPRESULTHASMEASUREDVALUE sy-vline
WA_CINSPUSGESGLRSLT_STR-CHARACTERISTICATTRIBUTECODEGRP sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONVALUATIONRESULT sy-vline
WA_CINSPUSGESGLRSLT_STR-INSPECTIONRESULTMEASUREDVALUE sy-vline
WA_CINSPUSGESGLRSLT_STR-CHARACTERISTICATTRIBUTECODE sy-vline
WA_CINSPUSGESGLRSLT_STR-CHARACTERISTICATTRIBUTECODETXT sy-vline
WA_CINSPUSGESGLRSLT_STR-CHANGEDDATETIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.