ABAP Select data from SAP table CKF_BO_INT_ACTIVITY_DISPLAY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CKF_BO_INT_ACTIVITY_DISPLAY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CKF_BO_INT_ACTIVITY_DISPLAY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CKF_BO_INT_ACTIVITY_DISPLAY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CKF_BO_INT_ACTIVITY_DISPLAY TYPE STANDARD TABLE OF CKF_BO_INT_ACTIVITY_DISPLAY,
      WA_CKF_BO_INT_ACTIVITY_DISPLAY TYPE CKF_BO_INT_ACTIVITY_DISPLAY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CKF_BO_INT_ACTIVITY_DISPLAY> TYPE CKF_BO_INT_ACTIVITY_DISPLAY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CKF_BO_INT_ACTIVITY_DISPLAY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CKF_BO_INT_ACTIVITY_DISPLAY
  INTO TABLE IT_CKF_BO_INT_ACTIVITY_DISPLAY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CKF_BO_INT_ACTIVITY_DISPLAY
*  INTO TABLE @DATA(IT_CKF_BO_INT_ACTIVITY_DISPLAY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CKF_BO_INT_ACTIVITY_DISPLAY INDEX 1 INTO DATA(WA_CKF_BO_INT_ACTIVITY_DISPLAY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CKF_BO_INT_ACTIVITY_DISPLAY ASSIGNING <CKF_BO_INT_ACTIVITY_DISPLAY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CKF_BO_INT_ACTIVITY_DISPLAY>-ITEM_CATEGORY = 1.
<CKF_BO_INT_ACTIVITY_DISPLAY>-COSTING_VARIANT = 1.
<CKF_BO_INT_ACTIVITY_DISPLAY>-COSTING_VERSION = 1.
<CKF_BO_INT_ACTIVITY_DISPLAY>-OBJECT_NUMBER = 1.
<CKF_BO_INT_ACTIVITY_DISPLAY>-TOTAL = 1.
ENDLOOP.

LOOP AT IT_CKF_BO_INT_ACTIVITY_DISPLAY INTO WA_CKF_BO_INT_ACTIVITY_DISPLAY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CKF_BO_INT_ACTIVITY_DISPLAY-FIXED, sy-vline,
WA_CKF_BO_INT_ACTIVITY_DISPLAY-CURRENCY, sy-vline,
WA_CKF_BO_INT_ACTIVITY_DISPLAY-CREATION_DATE, sy-vline,
WA_CKF_BO_INT_ACTIVITY_DISPLAY-CREATION_TIME, sy-vline,
WA_CKF_BO_INT_ACTIVITY_DISPLAY-QUANTITY, sy-vline,
WA_CKF_BO_INT_ACTIVITY_DISPLAY-UNIT_OF_MEASURE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CKF_BO_INT_ACTIVITY_DISPLAY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CKF_BO_INT_ACTIVITY_DISPLAY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CKF_BO_INT_ACTIVITY_DISPLAY INTO WA_CKF_BO_INT_ACTIVITY_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CKF_BO_INT_ACTIVITY_DISPLAY-UNIT_OF_MEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CKF_BO_INT_ACTIVITY_DISPLAY-UNIT_OF_MEASURE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRICE_UNIT_MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CKF_BO_INT_ACTIVITY_DISPLAY-PRICE_UNIT_MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CKF_BO_INT_ACTIVITY_DISPLAY-PRICE_UNIT_MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COST_ELEMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CKF_BO_INT_ACTIVITY_DISPLAY-COST_ELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CKF_BO_INT_ACTIVITY_DISPLAY-COST_ELEMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COST_CENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CKF_BO_INT_ACTIVITY_DISPLAY-COST_CENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CKF_BO_INT_ACTIVITY_DISPLAY-COST_CENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CKF_BO_INT_ACTIVITY_DISPLAY_STR,
ITEM_CATEGORY TYPE STRING,
COSTING_VARIANT TYPE STRING,
COSTING_VERSION TYPE STRING,
OBJECT_NUMBER TYPE STRING,
TOTAL TYPE STRING,
FIXED TYPE STRING,
CURRENCY TYPE STRING,
CREATION_DATE TYPE STRING,
CREATION_TIME TYPE STRING,
QUANTITY TYPE STRING,
UNIT_OF_MEASURE TYPE STRING,
PRICE_UNIT TYPE STRING,
PRICE_UNIT_MEINS TYPE STRING,
STRUCTURE TYPE STRING,
STRUCTURE_AUX TYPE STRING,
COST_ELEMENT TYPE STRING,
PRICE_STRATEGY TYPE STRING,
PLANT TYPE STRING,
ACTIVITY_TYPE TYPE STRING,
COST_CENTER TYPE STRING,
CONTROLLING_AREA TYPE STRING,
ORIGIN_GROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-ITEM_CATEGORY sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-COSTING_VARIANT sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-COSTING_VERSION sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-OBJECT_NUMBER sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-TOTAL sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-FIXED sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-CURRENCY sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-CREATION_DATE sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-CREATION_TIME sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-QUANTITY sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-UNIT_OF_MEASURE sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-PRICE_UNIT sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-PRICE_UNIT_MEINS sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-STRUCTURE sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-STRUCTURE_AUX sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-COST_ELEMENT sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-PRICE_STRATEGY sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-PLANT sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-ACTIVITY_TYPE sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-COST_CENTER sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-CONTROLLING_AREA sy-vline
WA_CKF_BO_INT_ACTIVITY_DISPLAY_STR-ORIGIN_GROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.