ABAP Select data from SAP table CLCMCTXICNTCTTP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CLCMCTXICNTCTTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CLCMCTXICNTCTTP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CLCMCTXICNTCTTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CLCMCTXICNTCTTP TYPE STANDARD TABLE OF CLCMCTXICNTCTTP, WA_CLCMCTXICNTCTTP TYPE CLCMCTXICNTCTTP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CLCMCTXICNTCTTP> TYPE CLCMCTXICNTCTTP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CLCMCTXICNTCTTP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CLCMCTXICNTCTTP INTO TABLE IT_CLCMCTXICNTCTTP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CLCMCTXICNTCTTP * INTO TABLE @DATA(IT_CLCMCTXICNTCTTP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CLCMCTXICNTCTTP INDEX 1 INTO DATA(WA_CLCMCTXICNTCTTP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CLCMCTXICNTCTTP ASSIGNING <CLCMCTXICNTCTTP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CLCMCTXICNTCTTP>-MANDT = 1.
<CLCMCTXICNTCTTP>-LGLCNTNTMCNTXTINTCNTCTUUID = 1.
<CLCMCTXICNTCTTP>-LGLCNTNTMCONTEXTUUID = 1.
<CLCMCTXICNTCTTP>-LGLCNTNTMRANK = 1.
<CLCMCTXICNTCTTP>-LGLCNTNTMINTCNTCTUSER = 1.
ENDLOOP. LOOP AT IT_CLCMCTXICNTCTTP INTO WA_CLCMCTXICNTCTTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CLCMCTXICNTCTTP-FIRSTNAME, sy-vline,
WA_CLCMCTXICNTCTTP-LASTNAME, sy-vline,
WA_CLCMCTXICNTCTTP-FULLNAME, sy-vline,
WA_CLCMCTXICNTCTTP-LGLCNTNTMINTCNTCTTYPE, sy-vline,
WA_CLCMCTXICNTCTTP-LGLCNTNTMINTCNTCTTYPENAME, sy-vline,
WA_CLCMCTXICNTCTTP-DEPARTMENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CLCMCTXICNTCTTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CLCMCTXICNTCTTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CLCMCTXICNTCTTP INTO WA_CLCMCTXICNTCTTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit SXIDN, internal->external for field EMAILADDRESS CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_CLCMCTXICNTCTTP-EMAILADDRESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLCMCTXICNTCTTP-EMAILADDRESS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CLCMCTXICNTCTTP_STR,
MANDT TYPE STRING,
LGLCNTNTMCNTXTINTCNTCTUUID TYPE STRING,
LGLCNTNTMCONTEXTUUID TYPE STRING,
LGLCNTNTMRANK TYPE STRING,
LGLCNTNTMINTCNTCTUSER TYPE STRING,
FIRSTNAME TYPE STRING,
LASTNAME TYPE STRING,
FULLNAME TYPE STRING,
LGLCNTNTMINTCNTCTTYPE TYPE STRING,
LGLCNTNTMINTCNTCTTYPENAME TYPE STRING,
DEPARTMENT TYPE STRING,
EMAILADDRESS TYPE STRING,
LGLCNTNTMISMANDATORY TYPE STRING,
LGLCNTNTMISINTEGRELEVANT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CLCMCTXICNTCTTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CLCMCTXICNTCTTP_STR-MANDT sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMCNTXTINTCNTCTUUID sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMCONTEXTUUID sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMRANK sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMINTCNTCTUSER sy-vline
WA_CLCMCTXICNTCTTP_STR-FIRSTNAME sy-vline
WA_CLCMCTXICNTCTTP_STR-LASTNAME sy-vline
WA_CLCMCTXICNTCTTP_STR-FULLNAME sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMINTCNTCTTYPE sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMINTCNTCTTYPENAME sy-vline
WA_CLCMCTXICNTCTTP_STR-DEPARTMENT sy-vline
WA_CLCMCTXICNTCTTP_STR-EMAILADDRESS sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMISMANDATORY sy-vline
WA_CLCMCTXICNTCTTP_STR-LGLCNTNTMISINTEGRELEVANT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.