ABAP Select data from SAP table CMCB_S_GUI_DYN0100 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMCB_S_GUI_DYN0100 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMCB_S_GUI_DYN0100. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMCB_S_GUI_DYN0100 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMCB_S_GUI_DYN0100 TYPE STANDARD TABLE OF CMCB_S_GUI_DYN0100,
      WA_CMCB_S_GUI_DYN0100 TYPE CMCB_S_GUI_DYN0100,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMCB_S_GUI_DYN0100> TYPE CMCB_S_GUI_DYN0100.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMCB_S_GUI_DYN0100.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMCB_S_GUI_DYN0100
  INTO TABLE IT_CMCB_S_GUI_DYN0100.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMCB_S_GUI_DYN0100
*  INTO TABLE @DATA(IT_CMCB_S_GUI_DYN01002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMCB_S_GUI_DYN0100 INDEX 1 INTO DATA(WA_CMCB_S_GUI_DYN01002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMCB_S_GUI_DYN0100 ASSIGNING <CMCB_S_GUI_DYN0100>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMCB_S_GUI_DYN0100>-OKCODE = 1.
<CMCB_S_GUI_DYN0100>-SAVEOK = 1.
<CMCB_S_GUI_DYN0100>-OBJVERS = 1.
<CMCB_S_GUI_DYN0100>-OBJVERSICON = 1.
<CMCB_S_GUI_DYN0100>-PROCESSFLOW = 1.
ENDLOOP.

LOOP AT IT_CMCB_S_GUI_DYN0100 INTO WA_CMCB_S_GUI_DYN0100.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMCB_S_GUI_DYN0100-PROCESSFLOWT, sy-vline,
WA_CMCB_S_GUI_DYN0100-DYNNR, sy-vline,
WA_CMCB_S_GUI_DYN0100-SAVED, sy-vline,
WA_CMCB_S_GUI_DYN0100-SAVEDICON, sy-vline,
WA_CMCB_S_GUI_DYN0100-SAVEDTXT, sy-vline,
WA_CMCB_S_GUI_DYN0100-OBJSTATICON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMCB_S_GUI_DYN0100 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMCB_S_GUI_DYN0100 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMCB_S_GUI_DYN0100 INTO WA_CMCB_S_GUI_DYN0100. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMCB_S_GUI_DYN0100_STR,
OKCODE TYPE STRING,
SAVEOK TYPE STRING,
OBJVERS TYPE STRING,
OBJVERSICON TYPE STRING,
PROCESSFLOW TYPE STRING,
PROCESSFLOWT TYPE STRING,
DYNNR TYPE STRING,
SAVED TYPE STRING,
SAVEDICON TYPE STRING,
SAVEDTXT TYPE STRING,
OBJSTATICON TYPE STRING,
CB_AREA TYPE STRING,
CB_AREA_DESC TYPE STRING,
CYCLE_TYPE TYPE STRING,
CYCLE_TYPE_DESC TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMCB_S_GUI_DYN0100_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMCB_S_GUI_DYN0100_STR-OKCODE sy-vline
WA_CMCB_S_GUI_DYN0100_STR-SAVEOK sy-vline
WA_CMCB_S_GUI_DYN0100_STR-OBJVERS sy-vline
WA_CMCB_S_GUI_DYN0100_STR-OBJVERSICON sy-vline
WA_CMCB_S_GUI_DYN0100_STR-PROCESSFLOW sy-vline
WA_CMCB_S_GUI_DYN0100_STR-PROCESSFLOWT sy-vline
WA_CMCB_S_GUI_DYN0100_STR-DYNNR sy-vline
WA_CMCB_S_GUI_DYN0100_STR-SAVED sy-vline
WA_CMCB_S_GUI_DYN0100_STR-SAVEDICON sy-vline
WA_CMCB_S_GUI_DYN0100_STR-SAVEDTXT sy-vline
WA_CMCB_S_GUI_DYN0100_STR-OBJSTATICON sy-vline
WA_CMCB_S_GUI_DYN0100_STR-CB_AREA sy-vline
WA_CMCB_S_GUI_DYN0100_STR-CB_AREA_DESC sy-vline
WA_CMCB_S_GUI_DYN0100_STR-CYCLE_TYPE sy-vline
WA_CMCB_S_GUI_DYN0100_STR-CYCLE_TYPE_DESC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.