ABAP Select data from SAP table CMCBD_LQH_HIER into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMCBD_LQH_HIER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMCBD_LQH_HIER. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CMCBD_LQH_HIER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CMCBD_LQH_HIER TYPE STANDARD TABLE OF CMCBD_LQH_HIER, WA_CMCBD_LQH_HIER TYPE CMCBD_LQH_HIER, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CMCBD_LQH_HIER> TYPE CMCBD_LQH_HIER. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CMCBD_LQH_HIER. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CMCBD_LQH_HIER INTO TABLE IT_CMCBD_LQH_HIER. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CMCBD_LQH_HIER * INTO TABLE @DATA(IT_CMCBD_LQH_HIER2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CMCBD_LQH_HIER INDEX 1 INTO DATA(WA_CMCBD_LQH_HIER2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CMCBD_LQH_HIER ASSIGNING <CMCBD_LQH_HIER>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMCBD_LQH_HIER>-MANDT = 1.
<CMCBD_LQH_HIER>-CB_AREA = 1.
<CMCBD_LQH_HIER>-CYCLE_ID = 1.
<CMCBD_LQH_HIER>-NODEID = 1.
<CMCBD_LQH_HIER>-HIER_ID = 1.
ENDLOOP. LOOP AT IT_CMCBD_LQH_HIER INTO WA_CMCBD_LQH_HIER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CMCBD_LQH_HIER-PARENTID, sy-vline,
WA_CMCBD_LQH_HIER-CHILDID, sy-vline,
WA_CMCBD_LQH_HIER-NEXTID, sy-vline,
WA_CMCBD_LQH_HIER-NODELEVEL, sy-vline,
WA_CMCBD_LQH_HIER-NODE_REF_KEY, sy-vline,
WA_CMCBD_LQH_HIER-DIRECTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMCBD_LQH_HIER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMCBD_LQH_HIER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMCBD_LQH_HIER INTO WA_CMCBD_LQH_HIER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field CYCLE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMCBD_LQH_HIER-CYCLE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMCBD_LQH_HIER-CYCLE_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field HIER_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMCBD_LQH_HIER-HIER_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMCBD_LQH_HIER-HIER_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DIRECTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMCBD_LQH_HIER-DIRECTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMCBD_LQH_HIER-DIRECTION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMCBD_LQH_HIER_STR,
MANDT TYPE STRING,
CB_AREA TYPE STRING,
CYCLE_ID TYPE STRING,
NODEID TYPE STRING,
HIER_ID TYPE STRING,
PARENTID TYPE STRING,
CHILDID TYPE STRING,
NEXTID TYPE STRING,
NODELEVEL TYPE STRING,
NODE_REF_KEY TYPE STRING,
DIRECTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMCBD_LQH_HIER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMCBD_LQH_HIER_STR-MANDT sy-vline
WA_CMCBD_LQH_HIER_STR-CB_AREA sy-vline
WA_CMCBD_LQH_HIER_STR-CYCLE_ID sy-vline
WA_CMCBD_LQH_HIER_STR-NODEID sy-vline
WA_CMCBD_LQH_HIER_STR-HIER_ID sy-vline
WA_CMCBD_LQH_HIER_STR-PARENTID sy-vline
WA_CMCBD_LQH_HIER_STR-CHILDID sy-vline
WA_CMCBD_LQH_HIER_STR-NEXTID sy-vline
WA_CMCBD_LQH_HIER_STR-NODELEVEL sy-vline
WA_CMCBD_LQH_HIER_STR-NODE_REF_KEY sy-vline
WA_CMCBD_LQH_HIER_STR-DIRECTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.